Applicability of Siemens gas analyzer 7MB2335-0NH06-3AA1Use ambient air (depending on the tested component) for automatic device calibration; The cycle time can be adjusted within the range of 0 (1)... 24 hours. The gas analyzer ULTRAMAT 23 is used to measure one infrared component and oxygen and hydrogen sulfide. The 19 inch pull-out device is installed in the control cabinet to measure the gas interface 6mm tube. There is no internal measurement gas pump to measure the SO2 concentration range. Parallel measurement of SO2 and NO2 with UV photometer. Minimum measurement sample: 0 to 500 vpm. Maximum measurement range: 0 to 2500 vpm. No electrochemical oxygen sensor. No H2S sensor. Auxiliary energy: 230VAC, 50Hz. Operating software, documentation in English.
Siemens gas analyzer 7MB2335-0NH06-3AA1Ordering Instructions
When measuring certain components, special selection rules must be followed.
Measurement of component nitrous oxide
7MB2335, 7MB2337, and 7MB2338
(Application: Silicon wafer production)
The measurement range is from 0 to 100/500 ppm (MB label "E")
Can only be used to measure nitrous oxide in ultra pure gases
7MB2337 and 7MB2338
(Application: Measurement according to Kyoto Protocol requirements)
The measurement range is from 0 to 500/5000 vpm (MB label "Y")
Simultaneously measuring carbon dioxide is required to correct for cross interference
7MB2337- * CP * 0- * SY * or
7MB2338- * DC * 0- * SY * (including nitric oxide measurement)
7MB2337 and 7MB2338
(Application with paramagnetic oxygen measurement unit and independent gas path)
7MB2337-4**80-**** - Z + C11
7MB2337-5**80-**** - Z + C11
7MB2338-4**80-**** - Z + C11
7MB2338-5**80-**** - Z + C11
Measure component SF6
7MB2335, 7MB2337, and 7MB2338
(Application: Silicon wafer production)
The measurement range is 0 to 500/2500 ppm (MB label "H")
Can only be used to measure SF6 gas in ultra pure gas
Calibration interval (MCERTs type 7MB2335, 7MB2337, 7MB2338)
ULTRAMAT 23, 19 'rack mounted and portable versions | |
|---|---|
General Information |
|
Measure components |
Maximum 4 |
range |
2/Measurement components |
display |
LCD display with adjustable LED backlight contrast; Function building; 80 characters (4 lines/20 characters) |
operating position |
Front wall panel, vertical |
compliance |
CE certification (EN 61000-6-2, EN 61000-6-4) |
Design, shell |
|
weight |
About 10 kg |
Protection level, 19 'rack and desktop models |
|
Electrical performance |
|
EMC anti-interference (electromagnetic compatibility) |
Meets the requirements of NAMUR NE21 or EN 61326-1 standards |
auxiliary power supply |
|
power consumption |
About 60 VA |
Electrical input and output |
|
Analog output |
By component, 0/2/4... 20 mA, NAMUR, floating point, maximum load 750 Ω |
relay output |
8. With conversion contacts that can be freely set, such as range recognition; 24 V AC/DC/1 A, Floating point, no spark |
Digital input |
3. Designed for 24V without voltage
|
serial interface |
RS 485 |