instrumentb2bHypersil Chiral chromatography column has been upgraded, and multi bond phase assisted chiral analysis has made new breakthroughs!

As early as 2019, Thermo Fisher Scientific responded to customer demand by launching three classic chiral bonding phases——Hypersil Chiral JT, AT, OTMeet the chiral analysis and preparation needs of customers. With the increasing growth of the chiral market and diverse customer demands, the Hypersil Chiral chromatography column has been upgraded, and the diversification of bonded phases is driving chiral analysis.

Highlights of chromatographic column upgrade:

The Hypersil Chiral chromatography column has undergone a comprehensive upgrade, introducing various new bonded phases.

Diversified bonding phases:Provide a rich selection of bonding phases to meet different chiral analysis needs and assist researchers in conducting chiral analysis more accurately.

Performance improvement:By optimizing the chromatographic column packing and structural design, the separation efficiency and resolution have been improved, the analysis time has been shortened, and the accuracy and reliability of the analysis results have been ensured.

Widely used:Suitable for multiple fields such as drug analysis, biological analysis, environmental monitoring, and food safety testing, providing strong support for the development of chiral analysis methods.

The upgrade of Hypersil Chiral chromatography column will undoubtedly promote the further development of chiral analysis technology, bringing more convenience and benefits to scientific research and industrial production.

图片

How can we select the corresponding chromatographic column based on appropriate analysis conditions when facing up to 19 types of rich bonded phases? Refer to the following figure and easily get √

图片

Multiple application scenarios,

Helping chiral analysis is easy to handle

01

Chinese Pharmacopoeia Project - Determination of Hydroxypropyl Piperazine Content in Hydroxypropyl Piperazine Capsules by Positive Phase High Performance Liquid Chromatography

Chromatographic column:Hypersil Chiral-AT 5μm, 4.6x250mm,PN:42105-254630

图片

Figure 1 Chromatograms of solvent (A), test solution (B), control solution (C), and system suitability solution (D) (click to view larger image)

02

Determination of Hydroxypropyl Piperazine Content in Leftover Hydroxypropyl Piperazine Oral Liquid by Reversed Phase High Performance Liquid Chromatography

Chromatographic column:Hypersil Chiral-IGT 5μm, 4.6x250mm, PN:44005-254630

图片

Figure 2. Hypersil Chiral IGT for the determination of levodropropizine in levodropropizine oral solution (click to view larger image)

03

Hypersil Chiral IXT for analysis of FMOC protection of chiral amino acids

Column: Hypersil Chiral IXT 5 μ m, 4.6x250mm, PN: 42305-254630

图片
图片
图片

Figure 3. Hypersil Chiral IXT for analysis of chiral amino acids protected by FMOC (click to view larger image)


Do not neglect the use and maintenance of chromatographic columns,Assist in the development of laboratory methods with half the effort

Switching from positive phase mode to negative phase mode:

Rinse the chromatography column with 20 times the column volume of methanol/ethanol (isopropanol) (90:10, v/v). Use a new mobile phase activated chromatography column with at least 20 times the column volume and a low flow rate of 0.3ml/min

If the salt of the buffer in the reverse phase is insoluble in methanol and/or ethanol, rinse the chromatography column with a suitable solvent (such as 50/50 methanol/water or 50/50 acetonitrile/water), and then activate the chromatography column with a new mobile phase

Once the chromatographic column is switched to reverse phase condition, it is not recommended to switch back to normal phase condition

preservation:

NP: n-hexane/isopropanol (90:10, v: v)

PO: Acetonitrile/isopropanol (95:5, v: v) or methanol/isopropanol (95:5, v: v)

RP: Methanol/water or acetonitrile/water, and the water ratio should always be below 20%

Regeneration:

Rinse the chromatography column with 100% ethanol or methanol (40 ℃) at an appropriate flow rate for 1-3 hours

For more detailed application and information on Hypersil Chiral chromatography column products, you can download the column product instructions and usage guide from Thermo Fisher, or contact Thermo Fisher sales and agents in your region.