Welcome Customer !
instrumentb2bCardiopulmonary Resuscitation Model Human CPR Resuscitation Model

1、 Model features:
1. The 2010 version of the KAJ/CPR390A computerized cardiopulmonary resuscitation (CPR) simulator is a first generation emergency training model developed to improve trainees' emergency response capabilities in the event of disasters or accidents, in accordance with the requirements of the American Heart Association (AHA) 2010 CPR&ECC guidelines.
2. The hair, facial skin, neck skin, and chest skin are made of imported thermoplastic elastomer mixed adhesive material, which is made of stainless steel molds and high-temperature injection molded by injection molding machines. The hair, facial skin, neck skin, and chest skin can be freely replaced.
3. Execution standard: American Heart Association (AHA) 2010 guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC).

This product highlights the auxiliary functions of CPR training operations, with full voice prompts, digital and indicator light prompts, which are more in line with clinical and teaching CPR operation requirements.
Execution standard: American Heart Association (AHA) 2010 CPR&ECC guidelines standard

Features:
The simulated human has obvious anatomical features, realistic hand feel, uniform skin color, realistic shape, and beautiful appearance.
Simulated vital signs:
In the initial state, the simulated human pupil is dilated and there is no pulsation in the carotid artery.
During the compression process, simulate the passive pulsation of the human carotid artery, with a pulsation frequency consistent with the compression frequency.
After successful rescue, the simulated human pupils returned to normal and the carotid artery began to pulsate autonomously.
Pupil dilation and carotid pulsation can be turned on and off by a switch.
Can perform artificial respiration and extracardiac compression. Standard airway opening can be performed, and the airway indicator light will turn on.
Two operation modes: CPR training and mode assessment can be performed.
Method 1: CPR training, which includes compression and blowing exercises.
• Mode 2: mode assessment: within the set time, according to the 2010 cardiopulmonary resuscitation standard, the ratio of correct pressing and blowing is 30:2, and five cycle operations are completed.

Controller display screen function:
Electronic monitoring: The electronic indicator light displays the open and pressed parts of the monitored airway. The correct and incorrect counts of artificial respiration and chest compressions.
■ Voice prompt: Chinese voice prompts throughout the training and assessment process, which can be turned on and off, and the volume can be adjusted.
■ Barcode display blowing volume: The correct blowing volume is 500-600ml-1000ml:
When the blowing volume is too low, the barcode will be yellow.
When the blowing volume is appropriate, the barcode is green.
When the blowing volume is too large, the barcode will be red.
The tidal volume blown in is too fast or too large, causing gas to enter the stomach and the indicator light to display; Digital counting display; Error language prompt;
The barcode displays the pressing depth, and the correct pressing depth is 5-6cm:
When the pressing depth is too low, the barcode will turn yellow.
When the pressing depth is appropriate, the barcode will turn green.
When the pressing depth is too large, the barcode will turn red.
■ The operation time can be set by oneself in seconds.
Operating frequency: The 2010 standard is at least 100 times per minute, and the value can also be set by oneself.
■ Power status: Using a 220V power supply, the output power is 12V after being stabilized by a voltage regulator. (Optional installation of lithium battery, suitable for direct use without external power supply.). )

Printer function:
Print the operation process after the operation is completed.
The content of the transcript includes operating methods, consciousness judgment, emergency breathing, pulse examination, checking breathing, removing foreign objects, operating frequency, ratio of compression and blowing, number of cycles, number of compressions and blowing in each cycle operation, number of correct/incorrect compressions, reasons and frequency of incorrect compressions, reasons and frequency of correct/incorrect blowing, reasons and frequency of blowing errors, set time, operating time, and assessment.

Material characteristics:
The facial skin, neck skin, chest skin, and hair are made of imported thermoplastic elastomer mixed adhesive material, which is made of stainless steel molds and high-temperature injection molded by an injection molding machine. It has the characteristics of accurate anatomical markings, realistic hand feel, uniform skin color, realistic shape, beautiful appearance, durability, no deformation during disinfection and cleaning, and easy disassembly and replacement. Its material has reached the same level as foreign counterparts.

Standard configuration:
■ Resuscitate a full body human model;
One display controller;
One luxurious hand pulled push type human body hard plastic box;
■ One recovery operation pad;
One power adapter;
One data cable;
■ One box of barrier facial mask (50 pieces/box);
Four sets of replaceable lung capsule devices;
■ One interchangeable leather;
1 CD of 2010 operation guide;
1 first aid manual;
One user manual.
Warranty card and certificate of conformity;

Shanghai Kangji Medical Equipment Co., Ltd. has invested huge manpower and financial resources in the research and development of cardiopulmonary resuscitation simulators and other medical teaching models, making due contributions to the social medical education cause.