Welcome Customer !
instrumentb2b2015 guideline standard cardiopulmonary resuscitation simulator, 2015 guideline standard cardiopulmonary resuscitation model

Product name:Small screen color display computer cardiopulmonary resuscitation training simulator

Model: KAJ/CPR590


Product Introduction:

Shanghai Kangji Medical KAJ/CPR590 Adult Cardiopulmonary Resuscitation TrainingmodelThe human product combines the 2010 cardiopulmonary resuscitation operation guide standards, highlighting the auxiliary functions of CPR training operations, as well as the ability to set various operation values by oneself, using a combination of LCD screen and digital tube display. More in line with clinical and teaching practice CPR operation requirements. Its core modules include a simulated human and a cardiopulmonary resuscitation LCD display screen. Training and assessment for cardiopulmonary resuscitation can be conducted. The necessary conditions for successful cardiopulmonary resuscitation (CPR) include changes in pupils, carotid pulsation, and airway opening. Suitable for social cardiopulmonary resuscitation training institutions, hospitals, medical schools, health schools and other medical institutions to conduct cardiopulmonary resuscitation training.
Execution standard: American Heart Association (AHA) 2010 CPR&ECC guidelines standard

Features:
3.5Inch LCD screen display: simulated electrocardiogram, text display,
The simulated human has obvious anatomical features, realistic hand feel, uniform skin color, realistic shape, and beautiful appearance.
Simulated vital signs:
1)In the initial state, the simulated human pupil is dilated and there is no pulsation in the carotid artery.
2
)During the compression process, simulate the passive pulsation of the human carotid artery, with a pulsation frequency consistent with the compression frequency.
3
)After successful rescue, the simulated human pupils returned to normal and the carotid artery began to pulsate autonomously.
4)Pupil dilation and contractioncarotid arteryPulsation can be turned on and off by a switch.
Can perform artificial respiration and extracardiac compression. Standard airway opening can be performed, and the airway indicator light will turn on.
■ Three operation modes: can be performedCPRTraining, mode assessment, and practical assessment.
1
)Method 1:CPRTraining can be done by pressing and blowing.
2
)Method 2: mode assessment, within the set time, according to2010cardiopulmonary resuscitationStandard, correct pressing and blowing frequency302The proportion, completed5A loop operation.
3)Method 3: Practical assessment, teachers can set their own operating time range, operating standards, cycle times, operating frequency, and the ratio of pressing and blowing.
Controller display screen function:
Electronic monitoring: The electronic indicator light displays the open and pressed parts of the monitored airway. The correct and incorrect counts of artificial respiration and chest compressions.
■ Voice prompt: Chinese voice prompts throughout the training and assessment process, which can be turned on and off, and the volume can be adjusted.
■ Text prompts: Chinese text prompts throughout the training and assessment process.
■ Barcode display blowing volume: The correct blowing volume is500~600ml-1000ml
1
)When the blowing volume is too low, the barcode is yellow.
2)When the blowing volume is appropriate, the barcode is green.
3)When the blowing volume is too large, the barcode will be red.
4)The tidal volume blown in is too fast or too large, causing gas to enter the stomach and the indicator light to display; Digital counting display; Error language prompt;
Barcode displays the depth of pressing, the correct depth of pressing5-6cm
1)When the pressing depth is too low, the barcode turns yellow.
2)When the pressing depth is appropriate, the barcode is green.
3)When the pressing depth is too large,barcodeFor red.
■ The operation time can be set by oneself in seconds.
Operating frequency: Standard: At least100time/Divide; You can also set the values yourself.
■ Power status: Adopting220VPower supply, output power after being stabilized by a voltage regulator12V(Optional installation of lithium battery, suitable for direct use without external power supply.)
Printer function:
Print the operation process after the operation is completed. The transcript covers operating methods, consciousness judgment, emergency breathing, pulse examination, checking breathing, removing foreign objects, operating frequency, ratio of compression and blowing, number of cycles, number of compressions and blowing in each cycle, and correct compression/Number of errors, reasons and frequency of incorrect pressing, correct blowing/Reasons and frequency of errors, reasons for blowing errors, set time, operation time, and assessment.
Material characteristics:
Emergency simulation of human facial skin, neck skin, chest skin, and hair, using imported thermoplastic elastomer mixed adhesive materials, made of stainless steel molds and high-temperature injection molded by injection molding machines. It has the characteristics of accurate anatomical landmarks, realistic hand feel, uniform skin color, realistic shape, beautiful appearance, durability, no deformation during disinfection and cleaning, and easy disassembly and replacement. Its materials have reached the same level as foreign counterparts.
Standard configuration:
■ Resuscitate the entire body of the human bodymodelOne;
One display controller;
One luxurious hand pulled push type human body hard plastic box;
■ One recovery operation pad;
One power adapter;
One data cable;
CPRBarrier facial mask(50Zhang/box)One box;
Four sets of replaceable lung capsule devices;
■ One interchangeable leather;
Two rolls of thermal printing paper;
2010Operation Guide CD1Plate;
■ Manual of Common Techniques for On site First Aid 1 Ben;
One user manual;
Warranty card and certificate of conformity;