Bomi Technology showcases multiple image testing equipment at CIOE China Light Expo
At the CIOE exhibition, Bomi Technology showcased its accumulation in image quality testing in the field of camera technology and applications, showcasing products such as multispectral light boxes, endoscopic testing system BOMI-TSECIT, and standard QC light box BM03QC.Dust DetectorThe main application locations are:
Dust DetectorThe working principle of is mainly based on the principles of light scattering and electrostatic induction.Principle of light scattering:
Dust analyzerThe aerosol to be tested is sucked into the detection chamber through a sampling pump, and the aerosol to be tested is divided into two parts at the branching point. One part is filtered into clean air after passing through a filter, which serves as a protective sheath to protect the components in the sensor room from contamination by the gas to be tested. The other part of the aerosol, as the sample to be tested, directly enters the sensor room. In the sensor room, the main components are laser diodes, lens groups, and photodetectors. When detecting, the laser emitted by the laser diode first forms a thin layer surface light source through a lens group. When thin layer light is irradiated on the aerosol flowing through the sensor chamber, scattering occurs, and the scattered light intensity is detected by a photodetector. After being illuminated, the photodetector generates an electrical signal proportional to the mass concentration of the aerosol. Then multiply by the voltage calibration coefficient, which is obtained by measuring specific concentrations of aerosols. The commonly used test aerosol for calibration is Arizona test dust (or ISO 12103-1, A1 test dust).
Principle of electrostatic induction
Utilize the dynamic charge induction between dust particles passing through the probe to generate a signal. The communication electrostatic technology determines the disturbance amount of the AC signal by monitoring the standard deviation of the charge signal, and determines the dust emission amount based on the magnitude of the instantaneous disturbance amount.
product standard
All dust meters comply with·
Industry standard WS/T206-2001 of the Ministry of Health: Determination of Inhalable Particulate Matter (PM10) in the Air of Public Places - Light Scattering Method·
The commonly used models in the market now include instruments such as SIDPAK, DUSTTRAK, LD, P-5L2C, Sintrol S300 series, etc. The accuracy and measurement range of these products also vary, with general accuracy of 0.01mg/m3 and 0.001mg/m3, and range of 0.01-100mg/m3 and 0.001-10mg/m3.
SIDPAK series
SIDEPAK AM510 personal dust analyzer is suitable for industrial hygiene and occupational safety, and can display real-time dust concentration and record data. Simple structure, quiet operation, easy to carry, minimizing interference and discomfort for staff to the greatest extent possible. Built in sampling pump, and can select different channels for sampling according to different needs.
DUSTTRAK series
DUSTTRAKTM II models 8530, 8531, and 8532 are desktop or handheld, suitable for any environment and application. The new DUSTTRAK II aerosol monitor is composed of battery driven, data recording, and light scattering laser photometer, which can provide real-time readings of aerosol mass concentration. They use sheath gas systems to isolate aerosols in the optical chamber, maintain optical cleanliness, and improve reliability and low maintenance costs. This instrument can be used in clean offices, as well as in harsh industrial workshops, construction sites, environmental monitoring, and other outdoor environments.
LD series
The LD-3C laser dust analyzer is an advanced pocket sized dust analyzer that uses laser as the light source and meets the industry standards of the Ministry of Health for rapid dust measurement; More than a thousand units have been used across the country.
This instrument is suitable for rapid determination of inhalable particulate matter (PM10) concentration in public places, detection of dust concentration in labor hygiene aspects such as industrial and mining production sites, monitoring of inhalable dust concentration in the field of environmental protection, and evaluation of purification efficiency of air purifiers. Introducing a complete set of production, manufacturing, testing, and calibration technologies and equipment from Japan
P-5L2C series
The P-5L2C portable microcomputer dust analyzer is a new generation of rapid dust measurement instrument developed by Beijing Binda Green Creation based on the introduction of the Japanese Shibata P-5L2 portable digital dust analyzer and the addition of microcontroller control. It is suitable for the rapid determination of PM10 concentration of inhalable particles in public places, as well as the determination of respiratory dust and total dust in labor hygiene aspects of industrial and mining enterprises. In recent years, thousands of P5 type instruments have been used throughout the country, making it the most advanced product among similar testing instruments.
Sintrol series
Dust removal system: During the transportation process of gas-solid two-phase fluid containing dust particles through pipelines and dust collectors, the collision and friction between dust particles and dust particles, dust particles and the inner wall of pipelines, dust particles and filter cartridges, and dust particles and flue gas will cause electrostatic charges on the dust particles The electrostatic charge is directly related to the dust content in the gas-solid two-phase fluid inside the pipeline. The arithmetic mean of the charge and the root mean square of the disturbance both reflect the dust content inside the pipeline This type of charge conversion is called electrostatic friction effect, or electrostatic induction. The UNIFTER dust switch adopts the principle of AC electrostatic induction to measure the changes in electrostatic charge and determine whether the bag dust removal system is operating normally. When the bag ruptures, the dust content in the gas-solid two-phase flow in the pipeline increases, and the electrostatic field strength also increases.
The S300 series dust meter adopts the measurement method of *. Once the dust concentration value of an order point is given, the entire range will be automatically generated by the instrument, and the dust meter will automatically track the changes in concentration value without the need for manual setting. Therefore, the repeatability, reliability, and ease of operation of S300 make it widely used in various industries such as feeding, filtration, and environmental protection. Typical applications: such as blast furnace gas TRT power generation, gas pressurized transportation, pulverized coal pressurized gasification, clean coal process, gas power generation, etc.
The S303 online dust detector is designed specifically for process monitoring of dust concentration trends, including bag filtration systems, ceramic filtration systems, or core filtration systems. The 303 online dust detector has switch output and 4-20mA analog signal output for monitoring the trend of dust concentration changes. Usually installed downstream of equipment such as filters, cyclones, dryers, etc. to monitor the concentration of solid particles. When the particle concentration in the airflow exceeds the required standard, the two alarm relays start to sound an alarm. It can also be used for process control under specific application conditions.