GPR1500, GPR18 explosion-proofoxygen analyzerExplosion proof oxygen analyzer for petrochemical industrial processes containing hydrogen and other flammable gases. The trace oxygen and percentageoxygen analyzerInstalled inside a sturdy Exd enclosure, this oxygen analyzer is suitable for hazardous areas when equipped with a flame arrester. Electrochemical sensors that have been verified through practice have reliable oxygen sensitivity and can measure oxygen levels as low as 0-1 ppm to 0-25%.
highlight
Multiple user configurable ranges
Universal or ATEX type
• Quickly recover from exposure to air
Combined with XLT sensors, it can measure in pure CO2 environments
GPR-1500 A is equipped with two alarms
High quality current sensor technology
The sensor has a lifespan of up to 24 to 36 months and low maintenance costs
• No need to frequently replenish electrolyte
• Good stability
Accuracy: ± 2% of rated range
Sensitivity:<0.5% range
4 standard measurement ranges
• Equipped with flame arrester (standard)
application
• Inert gas purity measurement
Gas quality measurement during the manufacturing process of double-layer glass windows
Protective gas inside small containers
Ensure the quality of natural gas
Monitoring of hydrocarbon raw materials does not require frequent replenishment of electrolyte
• Quality monitoring of ethylene pipelines
Petrochemical catalyst monitoring
• Monitoring of hydrocarbon raw materials
Technical Specifications
GPR-1500 A GPR-1500 N GPR-1500 N ATEX
Range 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%)
Under constant accuracy conditions, less than 2% of the selected range
Response time T90<10 seconds
Sensitivity (LDL) 0.05 ppm
Linearity<1% of range
Sensor Model
GPR-12-333, Used for inert gas flow
XLT-12-333, Used for gases with carbon dioxide content>0.5%
Sensor lifespan at 25 ℃ (77 ° F) and 1 atm environment for 24 months in<1000 ppm oxygen environment
Verification interval of 30 days
Inlet pressure 0.34-2 barg (5-30 PSI), outlet vent
Flow rate 0.5-1.0 Nl/m (1-2 SCFH)
Gas connection 1/8 "card sleeve connector
Gas path material: stainless steel
Display LCD display 7 x 3.5cm (2.75 x 1.375 "); Resolution 0.01
Enclosure fiberglass NEMA 4X, size 6.75 x 8.375 x 4.25 "fiberglass NEMA 4X, size 6.75 x 8.375 x 4.25"
Weight 3.6kg (8lbs)
Compensation temperature compensation output temperature
Signal output 4-20 mA or 1-5 V, optional Modbus 4-20 mA
Alarm: Two alarms that can be set by the user, no alarm
Working temperature GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)
XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F)
Power supply 12-28V DC non loop or 110-220 VAC 18-24 V DC
Universal UL for regional classification: Class I, Division 1, Group C, D hazardous areas, equipped with external fixation
An Barrier
ATEX: II 2 G
Ex ia IIB T4 Gb
Tamb -20 ° C to+50 ° C
Recovery time: Leave it in the air for 30 seconds and blow it with N2 for<1 hour until it reaches<10ppm
GPR-18 MS-2 GPR-18 GPR-28
Measurement range 0-1 ppm, 0-100, 0-100 ppm&0-1000 ppm 0-100 ppm, 0-100, 0-1000 ppm&0-1% (0-25% calibration only)
0-1%, 0-5%, 0-10% & 0-25%
Accuracy under constant conditions,<2% of rated range
Response time T90<20 seconds T90<10 seconds
Recovery time
O2 level: Air
Duration: 30 seconds
O2 target: 10 ppm
N2 recycling: 45 minutes
O2 level: Air
Duration: 2 minutes
O2 target: 10 ppm
N2 recycling: 60 minutes
O2 level: Air
Duration: 30 seconds
O2 target: 0.1%
N2 recycling: 30 seconds
Sensitivity (LDL)<0.5% range
Linear<1% range
Sensor model GPR-12-2000MS-2 GPR-12-333
XLT-12-333 (>0.5% on-site CO2)
GPR-11-32
XLT-11-24 (>0.5% on-site CO2)
At 25 º C (77 ° F) and 1 atmosphere
download
36 months;
Average O2<100 ppm
24 months;
Average O2<100 ppm
GPR-11-32 type: 32 months in air;
XLT-11-24 type: 24 months in air
Calibration cycle 1-3 months
Inlet pressure 0.34-2 barg (5-30 psi), maximum 100 psi; Equipped with air vents
Flow rate 0.5-1.0 Nl/m (1-2 SCFH)
1/8 '' or 1/4 '' compression pipe fittings for air circuit joints
Contact medium components made of stainless steel
Screen 3 and a half digits on red LED; Resolution: 0.01ppm GPR-18, 0.001ppm GPR-18MS2, 0.001% GPR-28
Shell - UL certified aluminum 30.4 x 29.2 x 26.7 cm (12 x 11.5 x 10.5 ") wall mounted, 22.7 kg (50 pounds)
Shell - ATEX Aluminum 40.6 x 45.7 x 27.9 cm (16 x 18 x 11 ") Wall Mounted, 31.8 kg (70 pounds)
Compensation temperature
Signal output 4-20 mA isolated, 0-1V
Alarm 2 adjustable C-type non blocking relays; Sensor and power failure
Working temperature 5 ° C to 45 ° C (41 ° F to 113 ° F) GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)
XLT sensor: -10 ° to 45 ° C (14 ° F to 113 ° F)
Power 100/120 or 220/240 V AC
certification
Compliant with UL standards: Class 1, Division 1, Groups B, C, D, Hazardous Area NEMA4/7 (for enclosures only)
ATEX:EExd d IIB+H2 T6