oxygen analyzer

NegotiableUpdate on 12/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
GPR1500 and GPR18 explosion-proof oxygen analyzers are used for explosion-proof oxygen analyzers in petrochemical industrial processes containing hydrogen and other flammable gases.
Product Details

GPR1500, GPR18 explosion-proofoxygen analyzerExplosion proof oxygen analyzer for petrochemical industrial processes containing hydrogen and other flammable gases. The trace oxygen and percentageoxygen analyzerInstalled inside a sturdy Exd enclosure, this oxygen analyzer is suitable for hazardous areas when equipped with a flame arrester. Electrochemical sensors that have been verified through practice have reliable oxygen sensitivity and can measure oxygen levels as low as 0-1 ppm to 0-25%.


highlight

Multiple user configurable ranges

Universal or ATEX type

• Quickly recover from exposure to air

Combined with XLT sensors, it can measure in pure CO2 environments

GPR-1500 A is equipped with two alarms

High quality current sensor technology

The sensor has a lifespan of up to 24 to 36 months and low maintenance costs

• No need to frequently replenish electrolyte

• Good stability

Accuracy: ± 2% of rated range

Sensitivity:<0.5% range

4 standard measurement ranges

• Equipped with flame arrester (standard)


application

• Inert gas purity measurement

Gas quality measurement during the manufacturing process of double-layer glass windows

Protective gas inside small containers

Ensure the quality of natural gas

Monitoring of hydrocarbon raw materials does not require frequent replenishment of electrolyte

• Quality monitoring of ethylene pipelines

Petrochemical catalyst monitoring

• Monitoring of hydrocarbon raw materials


Technical Specifications

GPR-1500 A GPR-1500 N GPR-1500 N ATEX

Range 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%)

Under constant accuracy conditions, less than 2% of the selected range

Response time T90<10 seconds

Sensitivity (LDL) 0.05 ppm

Linearity<1% of range

Sensor Model

GPR-12-333, Used for inert gas flow

XLT-12-333, Used for gases with carbon dioxide content>0.5%

Sensor lifespan at 25 ℃ (77 ° F) and 1 atm environment for 24 months in<1000 ppm oxygen environment

Verification interval of 30 days

Inlet pressure 0.34-2 barg (5-30 PSI), outlet vent

Flow rate 0.5-1.0 Nl/m (1-2 SCFH)

Gas connection 1/8 "card sleeve connector

Gas path material: stainless steel

Display LCD display 7 x 3.5cm (2.75 x 1.375 "); Resolution 0.01

Enclosure fiberglass NEMA 4X, size 6.75 x 8.375 x 4.25 "fiberglass NEMA 4X, size 6.75 x 8.375 x 4.25"

Weight 3.6kg (8lbs)

Compensation temperature compensation output temperature

Signal output 4-20 mA or 1-5 V, optional Modbus 4-20 mA

Alarm: Two alarms that can be set by the user, no alarm

Working temperature GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)

XLT sensor: -10 ° C to 45 ° C (14 ° F to 113 ° F)

Power supply 12-28V DC non loop or 110-220 VAC 18-24 V DC

Universal UL for regional classification: Class I, Division 1, Group C, D hazardous areas, equipped with external fixation

An Barrier

ATEX: II 2 G

Ex ia IIB T4 Gb

Tamb -20 ° C to+50 ° C

Recovery time: Leave it in the air for 30 seconds and blow it with N2 for<1 hour until it reaches<10ppm


GPR-18 MS-2 GPR-18 GPR-28

Measurement range 0-1 ppm, 0-100, 0-100 ppm&0-1000 ppm 0-100 ppm, 0-100, 0-1000 ppm&0-1% (0-25% calibration only)

0-1%, 0-5%, 0-10% & 0-25%

Accuracy under constant conditions,<2% of rated range

Response time T90<20 seconds T90<10 seconds

Recovery time

O2 level: Air

Duration: 30 seconds

O2 target: 10 ppm

N2 recycling: 45 minutes

O2 level: Air

Duration: 2 minutes

O2 target: 10 ppm

N2 recycling: 60 minutes

O2 level: Air

Duration: 30 seconds

O2 target: 0.1%

N2 recycling: 30 seconds

Sensitivity (LDL)<0.5% range

Linear<1% range

Sensor model GPR-12-2000MS-2 GPR-12-333

XLT-12-333 (>0.5% on-site CO2)

GPR-11-32

XLT-11-24 (>0.5% on-site CO2)

At 25 º C (77 ° F) and 1 atmosphere

download

36 months;

Average O2<100 ppm

24 months;

Average O2<100 ppm

GPR-11-32 type: 32 months in air;

XLT-11-24 type: 24 months in air

Calibration cycle 1-3 months

Inlet pressure 0.34-2 barg (5-30 psi), maximum 100 psi; Equipped with air vents

Flow rate 0.5-1.0 Nl/m (1-2 SCFH)

1/8 '' or 1/4 '' compression pipe fittings for air circuit joints

Contact medium components made of stainless steel

Screen 3 and a half digits on red LED; Resolution: 0.01ppm GPR-18, 0.001ppm GPR-18MS2, 0.001% GPR-28

Shell - UL certified aluminum 30.4 x 29.2 x 26.7 cm (12 x 11.5 x 10.5 ") wall mounted, 22.7 kg (50 pounds)

Shell - ATEX Aluminum 40.6 x 45.7 x 27.9 cm (16 x 18 x 11 ") Wall Mounted, 31.8 kg (70 pounds)

Compensation temperature

Signal output 4-20 mA isolated, 0-1V

Alarm 2 adjustable C-type non blocking relays; Sensor and power failure

Working temperature 5 ° C to 45 ° C (41 ° F to 113 ° F) GPR sensor: 5 ° C to 45 ° C (41 ° F to 113 ° F)

XLT sensor: -10 ° to 45 ° C (14 ° F to 113 ° F)

Power 100/120 or 220/240 V AC

certification

Compliant with UL standards: Class 1, Division 1, Groups B, C, D, Hazardous Area NEMA4/7 (for enclosures only)

ATEX:EExd d IIB+H2 T6