Welcome Customer !

Membership

Help

Shanghai Runliu Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Runliu Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    Shanghai Baoshan District Industrial Park, Hutai Road

Contact Now

ZGF-60kV/3mA DC High Voltage Generator (Integrated Unit)

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The ZGF-60kV/3mA DC high voltage generator is mainly suitable for conducting DC withstand voltage tests or DC leakage current tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, circuit breakers, generators, etc. in the power departments of 220kV power departments, industrial and mining, metallurgy, steel and other enterprises.

Product Details

ZGF-60kV/3mA DC High Voltage GeneratorTechnical Specifications:

1. Power supply: AC220V ± 10%, 50Hz ± 1%
2. Rated output voltage: 60kV, 120kV, 200kV, 300kV, 400kV, 600kV, 800kV
3. Rated output current: 2mA, 3mA, 5mA, 8mA, 10mA
4. Output voltage indication accuracy:<1 level
5. Output current indication accuracy:<1 level
6. Ripple factor: ≤ 0.5
7. 0.75 times output voltage indication accuracy:<1 level, with latch

Technical conditions:

ZGF-60kV/3mA DC High Voltage GeneratorPower supply: AC220V ± 10%, 50Hz ± 1%
Output voltage indication accuracy:<1 level
Output current indication accuracy:<1 level
Ripple factor: ≤ 0.5%
0.75 times output voltage indication accuracy:<1 level, with latch


1. Has low ripple coefficient, stable and reliable voltage output, no noise, and good reliability;
2. It has overvoltage, overcurrent, zero voltage starting and fault protection functions, with adjustable voltage protection values and intuitive display;
3. Voltage and current are displayed digitally, and there are readings when the power is turned on, making it easy to monitor the output status;
4ZGF-60kV/3mA DC High Voltage GeneratorEquipped with 0.75 times voltage conversion, convenient for testing zinc oxide lightning arresters;

Usage conditions:

Relative humidity: not exceeding 85% at 25 ℃, no condensation
Working mode: intermittent use for 30 minutes
Environmental temperature: -10~40 ℃
Altitude: below 1500m
3. ZGF-60kV/3mA DC High Voltage Generatorprotection function
Internal overvoltage protection, internal overcurrent protection
External overvoltage protection (adjustable protection voltage), external overcurrent protection or breakdown protection
Internal power protection
Non zero start protection
Timed voice alarm