- Phone
-
Address
Shanghai Baoshan District Industrial Park, Hutai Road
Shanghai Runliu Electric Co., Ltd
Shanghai Baoshan District Industrial Park, Hutai Road
ZGF-200kV/2mA DC High Voltage GeneratorUsage conditions:
Relative humidity: not exceeding 85% at 25 ℃, no condensation
Working mode: intermittent use for 30 minutes
Environmental temperature: -10~40 ℃
Altitude: below 1500m
3. DC high voltage generator protection function
Internal overvoltage protection, internal overcurrent protection
External overvoltage protection (adjustable protection voltage), external overcurrent protection or breakdown protection
Internal power protection
Non zero start protection
Timed voice alarm
| specification | 200kV/2mA | |||
| ZGF-200kV/2mA DC High Voltage GeneratorTechnical Specifications | ||||
| Output voltage (kV) | 200 | |||
| Output current (mA) | 2 | |||
| Output power (W) | 400 | |||
| Charging current (mA) | 3 | |||
| Control box weight (kg) | 4.5 | |||
| Weight of pressure doubling cylinder (kg) | 7.9 | |||
| Double pressure cylinder specification (mm) | F110 810 | |||
| Voltage measurement error | 1% (full degree) ± 1 word | |||
| Current measurement error | 1% (full degree) ± 1 word | |||
| Overvoltage setting error | Overvoltage protection adopts dip code setting, which is clear at a glance (accuracy ≤ 1.0%) | |||
| 0.75 switching error | High precision 0.75UDC-1mA single touch button (accuracy ≤ 1.0%) suitable for testing zinc oxide lightning arresters | |||
| Ripple coefficient | ≤0.5% | |||
| working method | Intermittent use: rated load 30 minutes 1.1 times rated voltage use: 10 minutes | |||
| working environment | Temperature: -10 ℃ to+40 ℃ | |||
| Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||
| Altitude: below 1500 meters | ||||
| With capacitive load | The capacitance of the test sample is unlimited | |||
| structural characteristics | Electrical insulation voltage doubling cylinder | |||
| Air insulation, no leakage concerns | ||||
ZGF-200kV/2mA DC High Voltage GeneratorPerformance characteristics:
Digital display of output voltage and current;
Can be converted to 75% voltage output at any time;
Equipped with overvoltage and overcurrent protection settings, and able to display the set voltage and current values;
Smooth adjustment of output voltage across the entire range;
*The protection function ensures that the potentiometer must be adjusted to zero before each boost;
When using a discharge rod for discharge, it does not affect the magnitude of the output voltage;
ZGF-200kV/2mA DC High Voltage GeneratorEquipped with output voltage timing function;
Equipped with overvoltage and overcurrent protection sound and light alarm functions;
Can work at full capacity for 30 minutes.