- Phone
-
Address
Shanghai Baoshan District Industrial Park, Hutai Road
Shanghai Runliu Electric Co., Ltd
Shanghai Baoshan District Industrial Park, Hutai Road
Product Features:
1ZGF-400kV/5mA DC High Voltage GeneratorThe chassis adopts a universal type chassis, which can be used both vertically and horizontally.
2. Adopting intermediate frequency voltage doubling circuit, applying PWM pulse width modulation technology and high-power IGBT devices.
3. Adopting voltage feedback, the output voltage stability is high, and the ripple coefficient is small ≤ 1%.
4. Full range smooth voltage regulation, fine voltage regulation accuracy ≤ 0.5%, stability ≤ 1%, voltage and current error 1% ± 1 word.
5. The boost potentiometer boosts the voltage from zero.
6. 0.75UDC1mA function button, convenient for testing zinc oxide lightning arrester, accuracy ≤ 1%.
7. The overvoltage protection adopts a dip code setting, which is clear at a glance with an error of ± 1%.
Technical parameters of ZGF-400kV/5mA DC high voltage generator:
| specification | 400kV/5mA | |||
| Technical Specifications | ||||
| Output voltage (kV) | 40 | |||
| Output current (mA) | 5 | |||
| Output power (W) | 2000 | |||
| Charging current (mA) | 5 | |||
| Control box weight (kg) | 12 | |||
| Weight of pressure doubling cylinder (kg) | 17 | |||
| Double pressure cylinder specification (mm) | F150 1140 | |||
| Voltage measurement error | 1% (full degree) ± 1 word | |||
| Current measurement error | 1% (full degree) ± 1 word | |||
| Overvoltage setting error | Overvoltage protection adopts dip code setting, which is clear at a glance (accuracy ≤ 1.0%) | |||
| 0.75 switching error | High precision 0.75UDC-1mA single touch button (accuracy ≤ 1.0%) suitable for testing zinc oxide lightning arresters | |||
| Ripple coefficient | ≤0.5% | |||
| working method | Intermittent use: rated load 30 minutes 1.1 times rated voltage use: 10 minutes | |||
| working environment | Temperature: -10 ℃ to+40 ℃ | |||
| Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | ||||
| Altitude: below 1500 meters | ||||
| With capacitive load | The capacitance of the test sample is unlimited | |||
| structural characteristics | Electrical insulation voltage doubling cylinder | |||
| Air insulation, no leakage concerns | ||||
Technical Indicators:
3.1. Output voltage polarity: Negative polarity
3.2 Working power supply: AC220V ± 10%, 50HZ
3.3 Voltage measurement error: Full scale 2% ± 1d, high-resolution 0.1KV
3.4 Current measurement error: Full scale 1% ± 1d, high-resolution 0.1UA
3.5. Ripple coefficient better than 1%
3.6 Voltage stability: ≤ 0.5% when the power grid fluctuates randomly by ± 10%
3.7Working mode: intermittent working system, working time not less than 30 minutes under rated voltage and current
3.8. Environmental temperature: -10 ℃ to 50 ℃
3.9. Relative humidity: ≤ 85% (25 ℃)
3.10. Altitude: 2000 meters