The ZCLDN-4M-150F radar level gauge is mainly used in remote measurement and control fields for sewage treatment plants, water treatment plants, mines, water conservancy, power plants, chemical plants, steel plants, hydrology, water resources, water environment, water pollution, mountain flood disasters, reservoir safety, and dam safety; Used for remote monitoring of sewage pipelines, rainwater pipelines, water supply pipelines, manholes, river and sea discharge outlets, and reservoirs; Used in industries such as smart city pipeline monitoring projects, water conservancy irrigation areas, open channel monitoring projects, smart water management monitoring projects, geological hazard monitoring projects, etc., it is not affected by medium temperature interference in copper and zinc smelting sites and can be scientifically managed

ZCLDN-4M-150F radar level gauge is not affected by medium temperature interference in copper zinc smelting sites,
1. Millimeter wave radar, with measurement accuracy up to±2mm, The minimum blind spot for measurement is 01m。
2. The smaller antenna size meets the measurement needs of more working conditions.
3. Multiple lens antennas, smaller emission angles, more concentrated energy, stronger echo signals, under the same mining conditions, compared toOther radar products have higher reliability.
4. It has stronger penetrability and can be used normally even in the presence of adhesion and condensation.
5. The dynamic signal range is larger, making it more stable for measuring low dielectric constant media.
6. Multiple measurement modes, with radar response time less than in fast measurement mode1S.
Intelligent microwave level instrument is used for detecting liquids, slurries, and other substances
Scope and characteristics of application
Continuous contact measurement of media with relatively small dielectric constants, such as granular materials, is suitable for situations with large temperature and pressure changes, and the presence of inert gases or vapors.
Has the following characteristics
1. Strong universality: It can measure liquid level and material level, meet the measurement requirements of different temperatures, pressures, and media, measure temperatures up to 800 ℃, pressures up to 5MPa, and can be applied to harsh environments such as corrosion and impact.
2. Anti hanging material: The circuit design and sensor structure ensure that its measurement is not affected by sensor hanging material, and there is no need for regular cleaning to avoid erroneous measurements.
3. Maintenance free: There are no movable parts during the measurement process, and there is no mechanical component damage issue, so no maintenance is required.
4. Anti interference: contact measurement, strong anti-interference ability, can overcome the influence of steam, foam and agitation on measurement.
5. Diversified measurement quantities make measurement more efficient, less affected by environmental changes, high stability, and long service life.
Main technical parameters
Measurement range: 0-6 meters, cable type can reach up to 35 meters;
Process connection: thread or flange;
Process temperature: -40-250 ℃;
Process pressure: -1.0 to 60 bar;
Operating frequency: 1.8GHz;
Response speed: ≥ 0.2s (depending on specific circumstances)
Repeatability: ± 3mm;
Resolution: 1mm;
Current signal: 4-20mA/HART;
Accuracy:<0.1%;
Communication interface: HART communication protocol;
Power supply: 24V DC (+/-10%)/Ripple voltage: 1Vpp;
Power consumption: max22.5mA;
Explosion proof certification: Exia II CT6;
Shell protection level: IP68;
Two wire wiring: power supply and signal output share a single two core wire;
Cable entrance: Two M20 x 1.5 (cable diameter 5... 9mm).