Phone
15224953586
-
Address
West side of Future Road South Section in Taikang County (Fuchaolou Town Development Zone)
Henan Yongxing Boiler Group Co., Ltd
15224953586
West side of Future Road South Section in Taikang County (Fuchaolou Town Development Zone)

1. The main heating surface is a coil structure, and the material used is GB3087 20 # boiler steel pipe. The design, manufacturing, and inspection of the boiler comply with the requirements of the national "Safety Supervision Regulations for Organic Heat Carrier Boilers".
2. The furnace temperature is high, the combustion efficiency is high, the exhaust emission concentration is low, and the sufficient heating surface and reasonable heating surface arrangement make the thermal efficiency of the boiler reach over 95%.
3. Low oil capacity, fast heating rate, and long service life.
4. Reasonable hot oil flow rate and overall consistency of flow rate ensure that furnace tubes will not burst due to carbon deposition, which not only ensures the safety of the boiler but also extends the service life of the oil.
5. Easy to install, convenient to use, small footprint, and aesthetically pleasing appearance.
Chinese screen control system
1. Full Chinese display, interface programmed design, clear and visible startup process, realistic animation of normal combustion interface,
2. Automatic/manual operation serves as a backup for each other. The automatic status system automatically detects the operating status of each control point and boiler unit, while the manual status system displays the current status of each detection point.
3. Control the start or stop of the unit according to the load requirements.
4. It can achieve timed power on and off at 4 times a day, and control the start-up time of the boiler unit according to the actual needs of the user.
performance advantage
Technical Specifications
| model | YYW120YQ | YYW240YQ | YYW350YQ | YYW470YQ | YYW700YQ | YYW950YQ | YYW1200YQ | YYW1500YQ | |
| project | parameter | ||||||||
| Heating capacity 104Kcal/h | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 125 | |
| Rated thermal power Kw | 120 | 240 | 350 | 470 | 700 | 950 | 1200 | 1500 | |
| Thermal efficiency% | 75 | 80 | 80 | 8080 | 82 | 85 | 85 | 85 | |
| Design pressure Mpa | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | |
| Maximum working temperature ℃ | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | |
| Furnace content oil quantity m3 | 0.10 | 0.20 | 0.28 | 0.35 | 0.50 | 0.70 | 1.00 | 1.3 | |
| Circulating oil quantity m3/h | 12.5 | 32 | 40 | 60 | 60 | 100 | 100 | 100 | |
| Pipe connection diameter mm | 50 | 80 | 80 | 100 | 100 | 125 | 125 | 125 | |
| System installed capacity Kw | 12 | 15 | 20 | 28 | 30 | 35 | 40 | 41 | |
|
appearance size |
Length mm | 1500 | 2000 | 2500 | 2700 | 3100 | 3500 | 3850 | 4350 |
| Width mm | 1150 | 1250 | 1350 | 1600 | 1650 | 1700 | 1800 | 1900 | |
| Height mm | 1400 | 1500 | 1650 | 1900 | 1950 | 2000 | 2160 | 2275 | |
| Equipment weight Kg | 2000 | 2900 | 3700 | 4500 | 4900 | 5500 | 6500 | 7500 | |
Technical Parametersnumber
| model | YYW1900YQ | YYW2400YQ | YYW3000YQ | YYW350YQ | YYW4200YQ | YYW4700YQ | YYW6000YQ | |
| project | parameter | |||||||
| Heating capacity 104Kcal/h | 160 | 200 | 250 | 300 | 360 | 400 | 500 | |
| Rated thermal power Kw | 1900 | 2400 | 3000 | 3500 | 4200 | 4700 | 6000 | |
| Thermal efficiency% | 85 | 85 | 85 | 85 | 85 | 85 | 85 | |
| Design pressure Mpa | 0.6 | 0.8 | 0.8 | 0.8 | 1 | 1 | 1 | |
| Maximum working temperature ℃ | 320 | 320 | 320 | 320 | 320 | 320 | 320 | |
| Furnace content oil quantity m3 | 1.7 | 1.8 | 2.4 | 3 | 3.2 | 3.7 | 4.5 | |
| Circulating oil quantity m3/h | 160 | 160 | 200 | 200 | 200 | 260 | 300 | |
| Pipe connection diameter mm | 125 | 150 | 150 | 200 | 200 | 200 | 250 | |
| System installed capacity Kw | 66 | 70 | 80 | 80 | 85 | 95 | 110 | |
|
appearance size |
Length mm | 4800 | 5300 | 5500 | 5800 | 6300 | 6500 | |
working principle