XDLR-2000 Fully Automatic Touchscreen Calorimeter

NegotiableUpdate on 04/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The XDLR-2000 touch screen calorimeter uses ARM as the main control chip and a 7-inch true color touch LCD screen to achieve simpler and more direct human-computer interaction, providing the possibility for future device networking and data sharing. It has the vast majority of functions and unparalleled reliability of a microcomputer calorimeter in the previous personal computer+controller mode. The experimental process of adding water, draining, stirring, ignition, temperature measurement, calculation, calibration, and printing is fully automated, avoiding human errors and greatly improving accuracy and precision. Single complete test time: 1018 min Coal testing equipment ignition time: 3-6 seconds (adjustable) Coal quality analysis instrument temperature measurement range: 0.0000 ℃ -45.000 ℃ Calorimeter resolution: 0.0001 ℃ Coal testing instrument usage environment: 5-40 ℃ (room temperature change should be 1 ℃ per measurement) Coal testing instrument relative humidity 85% Power supply: 220V 10% 50Hz

Product Details

Performance Characteristics
1. Using embedded ARM as the main control chip and a 7-inch true color touch LCD screen to achieve simpler and more direct human-computer interaction.
2. Adopting a modular 24 bit AD temperature acquisition circuit ensures a temperature measurement stability of one ten thousandth bit.
3. Utilizing the powerful data processing capabilities of computers and providing possibilities for future device networking and data sharing.
4. It has the vast majority of functions and unparalleled reliability of the microcomputer calorimeter in the previous "personal computer+controller" mode.
5. Real time cooling calibration, with relaxed requirements for environmental temperature, improves experimental accuracy while ensuring the stability of the instrument during long-term operation.
6. The data of sulfur, hydrogen, and water can be supplemented and automatically converted into high and low calorific values after the experiment is completed, which is more in line with the conventional experimental process.
The experimental process of adding water, draining, stirring, ignition, temperature measurement, calculation, calibration, and printing is fully automated, avoiding human errors and greatly improving accuracy and precision.
8. The machine has self-protection, self diagnostic technology, fast fault finding, and easy maintenance.
Technical Specifications
Single complete test time: 10-18 minutes
Heat capacity: approximately 10500 (J/K)
Ignition voltage: AC22V
Ignition time: 3-6 seconds (adjustable)
Temperature measurement range: 0.0000 ℃ -45.000 ℃
Resolution: 0.0001 ℃
Measurement accuracy: superior to the national standard GB/T213-2008
Usage environment: 5-40 ℃ (temperature change should be ≤ 1 ℃ per measurement) Relative humidity ≤ 85%
Power supply: 220V ± 10% 50Hz
Scope of application and compliance with standards
This product is suitable for measuring the calorific value of combustible substances such as coal, coke, petroleum, and solid biomass fuels.
This product complies with various standards such as GB/T213-2008 "Method for determination of calorific value of coal", GB/T483-2007 "General provisions for experimental methods of coal analysis", JJG672-2001 "Verification regulations for oxygen bomb calorimeter", etc.