- Phone
-
Address
3rd Floor, Building 1, No. 552 Liancao Road, Minhang District
Shanghai Aoxi Scientific Instrument Co., Ltd
3rd Floor, Building 1, No. 552 Liancao Road, Minhang District
X-ray Fluorescence Spectrometer EDX2880B
RoHS Directive, EN71-3 Toy Directive 94/62/EC Packaging Directive, Cl,Br, Zero halogen testing and other instruction detectors
EDX 2880B analyzer
Hardware performance and advantages
Non destructive, fast, and accurate
High precision, high resolution, high reliability
X-ray Fluorescence Spectrometer EDX2880BPerformance and configuration
Analysis range 1ppm to 100%
Accuracy RSD ≤ 0.05% Au ≥ 90%
Test the physical state of the sample, including solid, powder, and liquid
Light tube voltage 5KV~50KV/optional imported light tube
High voltage power supply 0~50KV
Light tube flow rate 0 μ A~1000 μ A
High definition camera
Collimator \ \ \ Filter Automatic Switching System
Detector Si Pin/SDD (optional)
分辨率 Si-pin160±5eV/SDD135±5eV
Multi channel analyzer ZPY-DMCP
Test time: 30sec~100sec
ROHS analysis of common elements Cl, S, Pb, Hg, Br, Cr, Cd, Ba, Sb, As... etc
Analysis software ZPY-FP qualitative and quantitative analysis software
Instrument environment requirements
Environmental temperature 15 ° C~30 ° C
Relative humidity 35%~70%
Power requirement: AC 220V ± 5V, 50/60HZ
There are no high-power electromagnetic and vibration interference sources nearby
Power supply: AC: 220V ± 5V
Technical performance and indicators: The range of elemental analysis ranges from sulfur (S) to uranium (U), and can analyze dozens or more elements. The coating has five layers and the thickness is generally within 50 μ m (different for each material);
The range of element content analysis is 1 PPm to 99.99%, and coating analysis can analyze samples with a thickness of 0.005um;
Measurement time: 100-300 seconds; The detection limit for harmful elements (limited to Cd/Pb/Cr/Hg/Br) specified in the RoHS directive is up to 1PPM;
The energy resolution is 149 ± 5 electron volts;
The temperature adaptation range is 15 ℃ to 30 ℃;
Power supply: AC 220V ± 5V; (It is recommended to configure an AC purification stabilized power supply.). )Product Features
EDX 2880B is a product specifically designed for environmental directives such as ROHS and EN71, and can also test the composition of materials and coating background simultaneously.
Breaking the traditional straight line design of instruments, adopting a streamlined integrated design, the instrument is stylish and elegant.
Adopting a new type of Si pin detector from the United States, electrically cooled instead of liquid nitrogen cooled, with small size, accurate data analysis, and low maintenance cost.
Adopting the independently developed SES signal processing system, the sensitivity of the measurement is effectively improved, making the measurement more accurate.
One click automatic testing, easier to use, more convenient, and more user-friendly.
Eight types of optical path calibration and collimation systems, automatically switching according to different samples.
Multiple anti radiation leakage design.
*The integrated heat dissipation design greatly improves the overall heat dissipation performance and ensures the safe operation of core components.
The unique temperature control technology of the movement ensures the safe and reliable operation of the X-ray source, effectively extending its service life and reducing usage costs.
Multiple instrument accessory protection system, and can be monitored throughout the entire process through software, making the instrument work more stable and safe.
ROHS testing software, standard window design, user-friendly interface, easy to operate.
This machine adopts USB 2.0 interface, effectively ensuring accurate, high-speed and effective data transmission.
Main hardware configuration of the instrument
Si pin electrically cooled semiconductor detector: (new type of detector) Si pin electrically cooled semiconductor detector; Resolution: 149 ± 5 electron volts
Amplification circuit module: detects sample characteristic X-rays; Further amplify the information collected through detection.
X-ray excitation device:
Filament current output: 1mA;
Belonging to semi consumable components, 50W, air-cooled.
High voltage launch device:
Maximum voltage output: 50kV;
Minimum 5kv controllable adjustment
Equipped with voltage overload protection
Digital multi-channel analyzer:
Convert the collected analog signals into digital signals and provide the processing results to the upper computer software.
The maximum number of roads: 4086;
Including signal enhancement processing
Optical path filtering module
Reduce interference during the transmission of X-ray light path to ensure accurate signal reception by the detector.
Integrate the collimator with the filter;
Collimator automatic switching module
Up to 8 options for free selection and switching.
Filter automatic switching module
Free selection and switching of six types of filters.
Automatic selection module for work curve
Automatically selecting work curves, eliminating manual selection, avoiding human operational errors, making automation and deduction more efficient, making operation more humane and convenient.
Software XRAYAnalyzer
Software Introduction
1) The Rohs analysis software developed specifically for ROHS testing processes, calculates, and reports measurement results of collected spectral signals.
2) A coating analysis software specifically developed for coating detection.
3) A full element analysis software specifically developed for alloy composition detection.
Feature Introduction
Specially designed to test the five elements Cd, Pb, Hg, Br, and Cr involved in the six substances in the EU RoHS directive, with a measurement time of 100-300 seconds
The operation interface is simple and intuitive, easy to use, and does not require professional operation
As shown in the following figure:

※ Suitable calibration curves can be automatically selected for easier and more accurate measurement.
The interface automatically switches between Chinese and English, and has a third-party language customization function
※ Automatic calibration instrument.
※ Comes with sample material qualitative analysis to prevent manual users from selecting the wrong curve
Multiple report formats are available for printing.
※ Multiple spectrograms can be displayed simultaneously
The unique temperature monitoring technology of the movement ensures the safe and reliable operation of the X-ray source, effectively extending its service life and reducing usage costs.
Sample configuration
Standard samples are used to create working curves
1 Sample chamber
Open sample cavity
2 standard samples
PE standard sample
Pure gold sample
Product warranty and after-sales service
1. Provide free training for customer operators.
Installation, debugging, acceptance, training, and technical services are all provided free of charge at the user's site to train operators.
Under normal use, if the malfunction is confirmed by our after-sales service department's technical personnel to be caused by process or material defects and has not been disassembled or repaired, the instrument will be covered by a one-year warranty from the date of acceptance.
Lifetime maintenance of 4 products. (Customers must provide detailed and authentic valid purchase vouchers, invoices, and warranty cards, etc.)
5. Provide free software upgrades;
Provide effective technical services, respond within 3 hours upon receiving user fault information, and send personnel to repair and troubleshoot within 48 hours if necessary.