- Phone
-
Address
3rd Floor, Building 1, No. 552 Liancao Road, Minhang District
Shanghai Aoxi Scientific Instrument Co., Ltd
3rd Floor, Building 1, No. 552 Liancao Road, Minhang District
WA2081 Atomic Absorption Spectrophotometer (Single Flame)Instrument features:
1. Two lamp positions, the number of preheating lamps can be customized to shorten the waiting time during use.
2. The lamp position is automatically optimized and can be adjusted in three dimensions to maximize energy.
3. Automatic memory of negative high voltage elements, one click completion of element wavelength scanning, lamp position optimization, and energy optimization.
4. The test results can be exported in various formats and opened directly with office software, making it more convenient and efficient.
5. The software can be remotely controlled, and remote technical support can be provided in case of problems, making problem resolution more timely.
6. Optional hydride generator.
7. Optional automatic ignition system.
WA2081 Atomic Absorption Spectrophotometer (Single Flame)detailed description:
The basic parameters of the instrument comply with the basic parameters of atomic absorption spectrophotometer specified in JJG694-2009 standard.
1、 Performance indicators:
1. Optical system
wavelength range |
190nm900nm |
Grating line density |
1800 items |
Monochromator |
Czerny-Turner 型 |
Spectral bandwidth |
0.2、0.4、1.0、2.0nm, Multi level automatic switching |
Wavelength accuracy |
±0.2nm |
wavelength repeatability |
0.05nm |
Baseline drift |
0.002A/30min |
detector |
Wide spectral range photomultiplier tube |
Spectral bandwidth deviation |
Copper lamp with a bandwidth deviation of 324.7nm and 0.2nm within ± 0.01nm. |
2. Light source system
lamp holder |
Automatic switching of lamp sockets |
Lamp power supply mode |
400Hz square wave pulse |
Lamp current adjustment range |
0 10mA average current |
3. Atomization system
Characteristic concentration (Cu) |
0.025μg/ml/1% |
Detection limit (Cu) |
0.006μg/ml |
burner |
100mm single seam titanium metal burner, air-cooled premixed type |
precision |
RSD≤1% |
sprayer |
Metal sheathed high-efficiency glass spray |
雾化室 |
Corrosion resistant all plastic atomization chamber |
safety measures |
Equipped with multiple automatic safety protection functions, acetylene leakage alarm and shutdown system |
4. Analysis methods
measurement method |
Air acetylene flame method, hydride generator atomic absorption method. |
Concentration calculation method |
Automatically fitting the working curve, automatically correcting sensitivity, and automatically calculating concentration and content. |
Repeated measurement times |
From 1 to 99 times, automatically calculate the mean, content, standard deviation, and relative standard deviation. |
Result printing |
Print stage test data or final analysis report. The results can be exported as an Excel worksheet. |
software environment |
Windows XP/Vista/Windows 7 operating systems, professional Chinese software |
2、 Instrument parameters:
power supply |
AC 220V/50HZ |
power |
150VA |
weight |
70kg |
volume |
1000mm (length) x 400mm (width) x 470mm (height) |
Working environment temperature |
10~35℃ |
Working environment humidity |
≤80% |
Application fields:
It can be widely applied in industries such as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental protection, and commercial inspection. In recent years, the application of trace and trace element analysis has gradually shifted from inorganic chemistry to organic chemistry.