| Model number | ES1010 | |
| measuretryinstrument | High voltage detector | Host (current clamp) |
| Range | 0.0mA~1200A (50/60Hz automatic) | 0.0mA~20A |
| dividedistinguishrate | 0.1mA | 0.1mA |
| Jaw size | φ50mm | φ8mm |
| precision | ±2%±5dgt | ±0.5%±5dgt |
| Sample Rate | 2 times per second | |
| workCan | Current, transformation ratio, polarity, phase, and online testing of primary and secondary circuits of high and low voltage current transformers; Online testing of current magnitude and transformation ratio on both sides of the transformer; Load current test | |
| transport type | Wireless transmission, straight transmission distance of 30m | |
| Shift gears | Fully automatic gear shifting | |
| Power supply | DC6V No.7 alkaline battery (1.5V AAA × 4) | DC7.5V No.5 alkaline battery (1.5V LR6 × 5) |
| testing mode | Clamp CT | |
| External dimensions | Width, thickness and height 87 * 37 * 262mm | Host: Width, Width, Height 100 * 35 * 204mm |
| Current clamp: width, thickness and height 42 * 20 * 137mm | ||
| display mode | LCD: 128 dots x 64 dots blue screen backlight function, suitable for dim places | |
| LCDchicun | 62mm×44mm | |
| Transformation ratio | Three types of transformation ratio display: (measured current transformation ratio in the primary and secondary circuits; converted transformation ratio based on 5A in the secondary circuit; Conversion ratio of transformer 10kV/380V to 10kV-YY, with a maximum ratio of 1:1 million (1.0K7) | |
| line voltage | Testing of insulated circuits below 60kV or bare wire current testing below 35kV (must be operated with insulation rods) | |
| Lead length | Current clamp lead wire 2 meters | |
| Quality | Total weight of instrument: 7Kg (including insulation rod and instrument package) | |
| High voltage detector: 370g (including battery) | ||
| Host: 409g (including battery) | ||
| Current clamp: 180g | ||
| data interface | USB TRANSFER | |
| Overflow display | Overscale overflow function: "OL A" symbol display | |
| Data Storage | 500 groups, according toHOLDKey holds data,MRSymbol display, press againHOLDKey Cancel Keep | |
| Data retrieval | Long pressHOLDThe key can enter the data lookup mode | |
| Full data storage | Data full function: "FULL" symbol display | |
| No signal indication | When the host does not receive the transmission signal, it prompts "NO SIGNAL-----” | |
| Automatic shutdown | After about 15 minutes of startup, the instrument panel will automatically shut down | |
| battery voltage | When the battery voltage drops to 4.8V, the low battery indicator light will turn on, reminding to replace the battery | When the battery voltage drops to 5.2V, the low battery voltage symbol is displayed, reminding to replace the battery |
| cut offreasonpole | Five section extendable insulation rod (5 meters) | |
| Dielectric Strength | AC 60kV/rms | |
| Line testing | Testing of insulated outer wires for line voltage below 60kV, and testing of bare wires below 60kV (with insulated rod operation) | |
| operation temperature | -10℃~40℃ | |
| Storage temperature | -10℃~60℃ | |
| relative humidity | 0℃~31℃≦75%,31℃~40℃≦50% | |
| Suitable for safety regulations | IEC1010-1、IEC1010-2-032、 Pollution level 2, CAT III (600V) IEC61326 (EMC standard) | |