- Phone
-
Address
2nd Floor, No. 81 Dalai South Road, Taihe Town, Baiyun District, Guangzhou City, Guangdong Province, China
Guangzhou Zhengneng Electronic Technology Co., Ltd
2nd Floor, No. 81 Dalai South Road, Taihe Town, Baiyun District, Guangzhou City, Guangdong Province, China
| Function | Measure three-phase AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, distinguish transformer wiring group, inductive and capacitive circuits, test secondary circuit and bus differential protection system, read out the phase relationship between CT of differential protection groups, check whether the wiring of the electricity meter is correct, and repair line equipment, etc | ||
| Power supply | 3.7V lithium rechargeable battery | ||
| Power consumption | Maximum 250mA | ||
| display mode | LCD color screen display, 72 × 55mm | ||
| Instrument size | Length, Width, and Thickness: 187 * 119 * 48mm | ||
| voltage range | AC 0.00V~600V | Resolution: AC 0.01V | Accuracy: ± 0.5FS |
| current range | AC 0.0mA~1000A | Resolution: AC 0.1mA | Accuracy: ± 0.5FS |
| Phase range | 0.0°~360.0° | Resolution: 0.1 ° | Accuracy: ± 1 ° |
| Frequency range | 45.00Hz~65.00Hz | Resolution: 0.01Hz | Accuracy: ± 0.5Hz |
| Active power range | 0.0W~600kW | Resolution: 0.1W | Accuracy: ± (3% rdg+3dgt) |
| Reactive power range | 0.0W~600kVAR | Resolution: 0.1VAR | Accuracy: ± (3% rdg+3dgt) |
| Visual power range | 0.0W~600kVA | Resolution: 0.1VA | Accuracy: ± (3% rdg+3dgt) |
| Power factor range | -1~+1 | Resolution: 0.001 | Accuracy: ± 0.03 |
| Current vector and | 0mA~3000A | Resolution: 1mA | |
| Phase sequence | Positive phase: U1, U2, U3 or I1, I2, I3 The cursor flashes sequentially from left to right Reverse phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from right to left |
||
| Detection rate | About 2 seconds/time | ||
| data hold | During the test, press the HOLD key to hold the data, and the "HOLD" symbol will be displayed | ||
| Data Storage | 400 sets | ||
| Silicone protective cover | have | ||
| USBinterface | USB interface, data stored can be uploaded to the computer for easy analysis and management of data | ||
| Automatic shutdown | After about 15 minutes of startup, the instrument panel automatically shuts down to reduce battery consumption | ||
| Backlight function | Yes, suitable for use in dark places and at night | ||
| Voltage detection | When the battery voltage is below 3.2V, the low battery voltage symbol is displayed to remind timely charging | ||
| Instrument quality | Host: 380g (with battery) | ||
| Large caliber current clamp: 440g × 3 | |||
| Test line: 190g | |||
| Length of voltage testing line | 1.5m | ||
| Current clamp wire length | 2m | ||
| Working temperature and humidity | -10℃~40℃; Below 80% Rh | ||
| Storage temperature and humidity | -10℃~60℃; Below 70% Rh | ||
| Input impedance | Test voltage input impedance: 1M Ω | ||
| Voltage resistance | The instrument circuit and the casing can withstand a sine wave AC voltage of 1000V/50Hz for 1 minute | ||
| Insulation | The distance between the instrument circuit and the casing is ≥ 100M Ω | ||
| Structure | Shell insulation | ||
| Suitable for safety regulations | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, Pollution Level 2 | ||