The price of the $r $n diesel generator set used in the air-cooled 12KW15 kW diesel generator start-up factory project is directly related to the materials used in the diesel generator set. Nowadays, with the rising prices of raw materials such as steel and copper in the market, the price of diesel generator sets is also constantly rising, especially last winter when the supply of electricity was in short supply. Many northern regions have already experienced power rationing, which has caused the price of diesel generator sets to rise again and again. The installation location of diesel generator sets should have good ventilation, with sufficient air inlet at the generator end and good air outlet at the diesel engine end. The area of the air outlet should be more than 1.5 times the area of the water tank.

Product Details

Wind cooled 12KW15 kW diesel generator for power plant start-up engineering

There are two types of Eur Y CIN diesel generators: open frame and low-noise cabinet type. Generally, open frame type is more commonly used in engineering and mining environments, while low-noise cabinet type is more commonly used for emergency backup in factories and households. The power of dual cylinder air-cooled diesel generators varies from 10KW, 12KW, to 15KW.

Silent generators have certain requirements for the operating environment, including temperature, altitude, humidity, etc. When the generator set is damp, we can restore normal use by drying it. There are also specially designed generator sets for use in different altitude areas. When the temperature is too high, we can also use both external cooling and the cooling system of the generator set. However, there is another detail worth paying attention to in terms of temperature, which is the thermal offset of the voltage.

When the ambient temperature and the temperature of the generator itself increase, the magnetic permeability of the generator core decreases, the DC resistance of the winding increases, and the parameters of the circuit components change, causing a change in the output voltage of the generator set. This phenomenon is called voltage thermal offset. Usually, the voltage thermal offset of the generator set is expressed by the percentage of the voltage change caused by the temperature rise to the rated voltage, and generally does not exceed 2%.

The faults of the silent generator set transformer include phase to phase short circuit, grounding short circuit, turn to turn short circuit, wire breakage, as well as burning of the iron core and faults of the bushing and lead wire. When a fault occurs outside the transformer, due to the large short-circuit current flowing through its winding, the temperature of the transformer will rise, and the transformer will operate under overload and overexcitation for a long time, which will also cause overheating and insulation damage to the winding and iron core. The transformer should be shut down for the following abnormalities: ① Transformer catching fire or smoking; ② Terminal overheating and melting, resulting in non full phase operation; ③ Shell rupture and significant oil leakage (for wet transformers); ④ The casing has serious rupture and discharge phenomena.

After the generator malfunctions, the cause and location of the malfunction should be identified first, and then corresponding measures should be taken to eliminate it. If necessary, it should be handled by professional generator repair or manufacturing enterprises. Precautions for the use of current transformers: For high-voltage windings, the secondary winding must be reliably grounded for protection during operation. This way, when the primary and secondary windings are broken down by high voltage due to insulation damage, the high voltage can be led to the ground to ensure personal and equipment safety. The secondary side of the current transformer must not have an open circuit. Maintenance items and maintenance cycle of transformers: The internal maintenance cycle of voltage transformers is once every 10 years; The internal maintenance cycle of the current transformer is once every 1-3 years. Maintenance items: ① Visual inspection; ② Insulation test.

Open frame dual cylinder 15KW diesel generator
Unit model EYC18000XE
rated power 15KW/18.75KVA
Peak Power 16KW/20kva
rated voltage 230V/400v
rated current 68.2/28.5A
rated frequency 50Hz
power factor 1.0/0.8
DC voltage 12V
DC current 8.3A
engine type Dual cylinder, four stroke, forced air cooling, direct injection
output power 18kW/3000rpm
Cylinder diameter x stroke 2-95mm×88mm
displacement 1240cc
Engine oil capacity 2.8L
Recommended lubricant model CD grade 10W-40
lubrication method splash lubrication
fuel consumption rate ≤320g/Kw.h
Fuel tank capacity 25L
Continuous operation time (50% f load) 8h
noise level 85DB
Startup method electric start
battery capacity 12V-36AH maintenance free battery
Dimensions (length x width x height) 1000×700×800mm
Weight (Kg) 259kg

Wind cooled 12KW15 kW diesel generator for power plant start-up engineering


Below are the differences between single cylinder air-cooled and dual cylinder air-cooled diesel engines in generators:


The power of a single cylinder air-cooled diesel engine is 168170178186188182198. A 3KW diesel generator is generally equipped with 178 power, a 5KW diesel generator with 186 power, a 6KW diesel generator with 188 power, and a 7KW diesel generator with 192 power. In fact, it is not recommended to equip a single cylinder air-cooled diesel engine with 198 power, as it is a single cylinder air-cooled engine and the power platform is too large, strong, and unstable. Generally, we use a single cylinder air-cooled 192 power engine with a 7KW diesel generator, a 4-inch high-pressure diesel engine water pump, and a 6-inch high flow diesel engine water pump. The advantage of a single cylinder air-cooled diesel engine is that it has a small volume, is easy to operate, and has good maneuverability. When the 7KW power cannot meet the customer's needs, if you don't care about volume and weight, it is recommended to equip a dual cylinder air-cooled KW can be used, dual cylinder air-cooled 8.5KW, 10KW diesel generator has stable performance, of course, the volume and weight are larger than single cylinder, and much smaller than water-cooled.