Silent speaker 10KW diesel generator single-phase 230V emergency power outage useFault handling:
Check the fuel filter element. If it is clogged or contains a large amount of impurities, please replace the fuel filter; Check the fuel supply pipeline, if there is any leakage, take measures to prevent air from entering the fuel supply pipeline during engine operation; Check the air filter element and clean or replace it with compressed air; Measure the fuel temperature. If the fuel temperature exceeds 50 ℃, please cool down or replenish the fuel to reduce its temperature; Check the engine exhaust pipe to ensure that it is unobstructed and that the exhaust pressure is less than 90mmHg; After being in a cold state or stopped for 5-10 minutes, check the oil level in the oil pan with the dipstick. If the oil level has exceeded the 'H' level, please drain the excess oil and keep the level between the 'L' and 'H' levels close to the 'H' level; During operation, use necessary tools to inspect the air pipe between the rear end of the turbocharger and the intake manifold (taking care to prevent burns caused by high temperature and high pressure gases), and tighten the parts with air leaks.
Diesel generators have fuel economy, high thermal efficiency, and a relatively flat fuel consumption curve when operating conditions change. They are also economical, reliable, and durable at low loads. Due to the absence of an ignition system, it has low malfunctions, a wide range of applications, low harmful emissions, and good fire safety.
| crew Generator |
model | EYC12000T\\T3 | |
| Frequency (Hz) | 50 | 60 | |
| Rotational speed (rpm) | 3000 | 3600 | |
| DC output (V.A) | 12V,8.3A | ||
| Voltage (V) | 220\\380,230\\400 | ||
| Rated power (kW) | 10 | 11 | |
| Maximum power (kW) | 11 | 12 | |
| Power factor Φ | 1\\0.8 | ||
| phase number | Single phase \ \ Three phase Single Phase\\Three Phase |
||
| excitation method | Brushed self-excited constant voltage (with AVR) Brush,exciting-self voltage-constant (with AVR) |
||
| type | Fully enclosed silent (square) Fully closed |
||
| Fuel tank capacity (L) | 25 | ||
| Continuous operating time (hr) (rated power) | 6 5.5 | ||
| Noise( Dba@7m ) | 73 | ||
| Weight (Kg) | 330 | ||
| Size (mm) (length x width x height) | 1110x710x985 | ||
| optional item | ATS | ||
| power Engine |
Power model | HD2V88 | |
| Startup method | Electric Starter | ||
| Power Type | Dual cylinder, V-shaped, four stroke, air-cooled, diesel engine V-Two,4-Stroke,Air Cooled, Vertical, Diesel Engine |
||
| Cylinder diameter x stroke (mm) | 88x75 | ||
| Displacement (L) | 0.870 | ||
| compression ratio | 20:1 | ||
| Rated power (KW/rpm) | 13.6/3000 | 14.8/3600 | |
| Fuel consumption (g/KW. h) | 235 | 245 | |
| Fuel type | 0 # (summer), -10 # (winter), -35 # (extreme cold) diesel 0#(Summer),-10#(Winter),-35#(Chill Cold) Diesel Oil |
||
| Lubricating oil type | 10W30 (CD level or above) 10W30(CD grade above) |
||
Silent speaker 10KW diesel generator single-phase 230V emergency power outage useIntroduction:
Small diesel generators 178/186, 188/192 emit black smoke when the engine is unloaded
Reason for malfunction: The air filter is clogged, causing insufficient intake of air into the engine; The engine's intake and exhaust pipes are not unobstructed or the intake and exhaust back pressure is too high; The fuel drain valve or fuel tank vent hole is blocked; The oil quality does not meet the requirements; Turbocharger malfunction; Other malfunctions.
Solution: Remove the air filter for inspection, clean or replace the air filter element to ensure smooth air intake. Check the engine intake and exhaust pipes to ensure that they remain unobstructed. Remove the pipeline and clean the supply and return oil pipelines. If necessary, replace the supply and return oil pipelines as well as the fuel tank vent pipe. Check the quality of the oil to ensure that it meets the requirements. Check if the turbocharger is rotating properly, then inspect the bearings for any dirt, and repair them if necessary. If the engine exhaust smoke still exceeds the standard after eliminating the above faults, please contact the generator manufacturer for handling.