The advantages of EO sterilization in the manufacturer's wholesale second-hand 10 cubic meter ethylene oxide sterilization cabinet are that it can be used for sterilization of items that are not resistant to high temperatures or moisture
Product Details
Wholesale supply of second-hand 10 cubic meter ethylene oxide sterilization cabinet from the manufacturer
EO sterilization and ethylene oxide sterilization are essentially the same sterilization method, with differences mainly in processing level and application scenarios: EO sterilization requires achieving a sterile level, while EO disinfection only needs to kill most pathogenic microorganisms.
Definition and processing level
EO sterilizationUsing ethylene oxide gas to disrupt the DNA, RNA, and protein structures of microorganisms through alkylation reactions,Kill all microorganisms, including bacterial spores, to achieve a sterile level (SAL ≤ 10 ⁻⁶).
EO disinfectionSame use of ethylene oxide gas, but only needs to kill most pathogenic microorganisms, reduce pollution risk, and does not requireAseptic, suitable for scenarios with low requirements for microbial control.
1 Source
Applicable subjects
EO sterilizationMainly used for high-risk medical devices such as surgical implants, catheters, and precision instruments that are not resistant to high temperatures or humidity.
EO disinfectionSuitable for medium to low-risk items, such as some laboratory equipment, or as a pre-treatment step before sterilization.
1 Source
operating procedure
EO sterilization process: Preprocessing (temperature and humidity regulation) →EO gas permeation (concentration 300-1200mg/L) →Sterilization stage (lasting for several hours) →Ventilation analysis (removal of residual EO).
EO disinfection processThe parameter requirements are lower than sterilization (such as shortening the action time or reducing the concentration), and ventilation is still required after the end, but the process is relatively simplified.
1 Source
Safety and residual
EO gas has moderate toxicity and can be absorbed through the respiratory tract and skin. Long term exposure may cause cellular abnormalities or cancer, and it is highly irritating.
Different products have strict requirements for the residual amount of EO, for example, disposable medical supplies generally do not exceed 10 μ g/g, and special products such as packaging require no more than 5 μ g/g.
After EO sterilization, analysis treatment (heating or natural analysis) is required to reduce residue and ensure safety.
2 sources
summary
Wholesale supply of second-hand 10 cubic meter ethylene oxide sterilization cabinet from the manufacturerEO sterilization and ethylene oxide sterilization are based on the same principleBoth use ethylene oxide gas to kill microorganisms, but EO sterilization emphasizessterileSuitable for high-risk or precision medical devices; And EO disinfection emphasizesReduce the number of microorganismsSuitable for medium to low-risk items or as a pre-treatment. There are differences between the two in terms of operating parameters, processing time, and residual management, and it is necessary to strictly follow standard operating procedures