- Phone
-
Address
No. 1210 Dongfang Avenue, Wuzhong Economic Development Zone, Suzhou
Suzhou Changliu Purification Technology Co., Ltd
No. 1210 Dongfang Avenue, Wuzhong Economic Development Zone, Suzhou
Wet full range laser particle size analyzerProduct Introduction
Winner2008 is an intelligent fully automatic laser particle size analyzer with a testing range covering millimeter, micrometer, submicron, and nanometer full ranges. Adopting a dual beam multispectral detection system and a new technology for ultrafine particle testing, the accuracy and performance of the instrument testing have been improved.
Main performance characteristics
New testing principle: This instrument adopts the classic Mie scattering principle and the converging light Fourier transformBased on technology and unconstrained free fitting data processing techniques, the spectrum amplification technology has been softened, making it easy to expand the testing range in a limited space;
Fully automated operation and calibration: In use, as long as the testing conditions are set according to the characteristics of the tested sample, a series of operations such as dispersion, testing, and flushing can be automatically completed, and accurate and reliable test results can be obtained. In addition, by using a three-dimensional alignment system to adjust the photodetector, the entire optical path system can be calibrated at any time to ensure accurate alignment, thereby providing strong guarantees for the accuracy and stability of test results, while avoiding the tedious process of manual debugging;
Effective dispersion and circulation system: In addition to conventional ultrasonic and stirring dispersion devices, a large flow circulation pump is specially equipped for wide distribution samples and particles with high specific gravity to prevent inaccurate test results caused by the loss of large particles. Therefore, this instrument has a wider applicability in different powder industries;
Accurate testing standards: Multiple national particle size standard materials at the micron, submicron, and nanometer levels are used to calibrate and calibrate the instrument across the entire measurement range, ensuring that true and accurate test results are obtained within its entire measurement range.
Wet full range laser particle size analyzerMain technical parameters:
Specification Model |
Winner2008A |
Winner2008B |
|
execution standard |
ISO 13320:2009; GB/T19077-2016; Q/0100JWN001-2013 |
||
test scope |
0.01-2000μm |
0.01-1200μm |
|
Number of detector channels |
127 |
120 |
|
Accuracy error |
≤ 0.5% (D50 value of national standard sample) |
||
repeatability error |
≤ 0.5% (D50 value of national standard sample) |
||
Laser parameters |
Main laser source: High performance He Ne laser with λ=632.8nm and p>2.0mW Auxiliary laser source: blue light laser, λ= 405nm; p>2mW, Service life:>25000H |
||
Built in dispersion method |
ultrasound |
Frequency: f=40KHz, Power: p=60W |
|
stir |
Speed: 0-3000rpm, adjustable speed |
||
cycle |
Rated flow rate: 30L/min Rated power: 70W |
||
sample pool |
Capacity: 1000mL |
||
Operation Mode |
Software operation/fully automatic operation mode can be switched |
||
Automatic centering system |
Fully automatic centering system |
||
test speed |
<2min/time |
||
volume |
1040mm*440mm*540mm |
||
weight |
58Kg |
||
Product Features
Adopting a fully built-in decentralized system: using a high-power circulation pump to optimize the pipeline design, the overall control coordination reaches the highest level, effectively preventing the secondary sedimentation of large particles.
Automatic alignment of optical path: The optical path automatic alignment system is composed of four hybrid stepper motors, with micro motion accuracy reaching the micrometer level, ensuring that the instrument's optical path is always in a normal state.
Unrestricted free fitting technology: a self-developed unconstrained free fitting technology for micro and nano particles, which is not limited by any function and can truly reflect the distribution state of particles.
Micro nano optical path design: using converging light Fourier transformTechnology enables scattered light to be unrestricted by lens aperture; Adopting a dual spectral surface optical path design, effectively expanding the measurement range to 2000 micrometers; Independently developed dual laser orthogonal optical path using semiconductor assisted laser to measure lateral scattering from 45 degrees to 141 degrees, further expanding the measurement range.
Scope of application
Winner2008 full range wet laser particle size analyzer is widely used in cement, ceramics, pharmaceuticals, coatings, dyes, pigments, fillers, chemical products, catalysts, coal powder, mud and sand, dust, flour, food, additives, pesticides, etc. with high requirements zhayaoGraphite, photosensitive materials, fuels, metal and non-metal powders, calcium carbonate, kaolin, coal water slurry, and other powder industries.