Waterproof manual alarm button IP67 addressable fire alarm
Using an encoder for write address encoding, no longer using dip switches.
Adopt programmer to input address code rather than using code switch.
Reset using the reset key without the need to replace the operation panel
Call point glass adopt reset key, not need to replace glass frequently.
Ultra thin structural design
Super thin structure design
Technical Specifications|Technical specifications
Working VoltageOperation voltage:DC18V~26V
power consumptionConsumption
Monitor currentMonitoring current:≤350uA
Alarm currentAlarm curren:≤1.5mA
technical standardTechnical standard:EN54-11
indicator lightIndicatorRed, flashing during inspection, constantly on after alarm
Red, flash in normal, light steady in alarm.
Operating TemperatureOperation temperature:-25°C~70°C
relative humidityRelative humidity:≤95%
Overall dimensionsDimension: 90x78.6x27.5 mm2
weightWeight: 200g
colorColor:redRed
protection levelIP degree::IP22 IP67
materialMaterial: ABS
Waterproof manual alarm button IP67 addressable fire alarm
scope of work•9-LoopFire alarm control panel(FACP)Replace•Replace all repeater panels.•Replace all detectors (smoke, heat, flame, multi-sensor).•Replace all manual call points (including weatherproof and intrinsic safety types).•Replace all interface modules and security barriers.•Door handle magnet replacement•Existing cabling infrastructure(9The loop should be preserved and reused (without the need to replace cables).•target, aim at, address, focus on, in response to9Each loop unit completes the comprehensive reprogramming and address mapping of the system.•System overall testing and debugging•Submission of completion drawings and technical documents•Training for ship crew on operation and maintenance.3. Technical Requirements•The addressable loop system operates at a voltage of24VDC.•The fire alarm control panel should be configured to at least9An addressable circuit.•with existing9Compatible with ring cabling infrastructure.•Ship type approval(DNV /ABS/LROr equivalent certification).•conform toSOLASrequirement.•EN54Authentication component•Battery backup capacity:24Hourly standby time+30Minute alarm status.•The system integration capability covers: video data recording system(VDR)Public broadcasting and intercom system, whistle control systemUnified engine alarm and monitoring system, as well as local fire control panel.