Welcome Customer !

Membership

Help

Shenzhen Hongsheng High tech Electronics Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shenzhen Hongsheng High tech Electronics Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 2 Fumin Road, Guanlan Street, Longhua New District, Shenzhen

Contact Now

Waterproof manual alarm button IP67 addressable fire alarm

NegotiableUpdate on 05/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The weatherproof manual alarm button IP67 addressable fire alarm uses an encoder for written address coding, eliminating the need for a dip switch. Reset with the reset key without the need to replace the control panel. Ultra thin structural design, with the highest waterproof rating of IP67 for marine use

Product Details

Waterproof manual alarm button IP67 addressable fire alarm

Using an encoder for write address encoding, no longer using dip switches.

Adopt programmer to input address code rather than using code switch.

Reset using the reset key without the need to replace the operation panel

Call point glass adopt reset key, not need to replace glass frequently.

Ultra thin structural design

Super thin structure design

Technical Specifications|Technical specifications

Working VoltageOperation voltageDC18V~26V

power consumptionConsumption

Monitor currentMonitoring current:≤350uA

Alarm currentAlarm curren:≤1.5mA

technical standardTechnical standardEN54-11

indicator lightIndicatorRed, flashing during inspection, constantly on after alarm

Red, flash in normal, light steady in alarm.

Operating TemperatureOperation temperature-25°C~70°C

relative humidityRelative humidity:95%

Overall dimensionsDimension: 90x78.6x27.5 mm2

weightWeight: 200g

colorColor:redRed

protection levelIP degree:IP22 IP67

materialMaterial: ABS

Waterproof manual alarm button IP67 addressable fire alarm

scope of work9-LoopFire alarm control panel(FACP)ReplaceReplace all repeater panels.Replace all detectors (smoke, heat, flame, multi-sensor).Replace all manual call points (including weatherproof and intrinsic safety types).Replace all interface modules and security barriers.Door handle magnet replacementExisting cabling infrastructure(9The loop should be preserved and reused (without the need to replace cables).target, aim at, address, focus on, in response to9Each loop unit completes the comprehensive reprogramming and address mapping of the system.System overall testing and debuggingSubmission of completion drawings and technical documentsTraining for ship crew on operation and maintenance.3. Technical RequirementsThe addressable loop system operates at a voltage of24VDC.The fire alarm control panel should be configured to at least9An addressable circuit.with existing9Compatible with ring cabling infrastructure.Ship type approval(DNV /ABS/LROr equivalent certification).conform toSOLASrequirement.EN54Authentication componentBattery backup capacity:24Hourly standby time+30Minute alarm status.The system integration capability covers: video data recording system(VDR)Public broadcasting and intercom system, whistle control systemUnified engine alarm and monitoring system, as well as local fire control panel.