LR certified fire sound and light alarm CCS marine fire alarm system
summary
Ultra thin structure, low-power design. Simultaneously emitting both sound and light alarm signals. There is an encoding circuit inside(No addressing required)When encoding, it can be directly connected to the alarm bus. When not encoding, a control module is required to enable it
characteristic|Feature
Simultaneously emitting both sound and light alarm signals.
Send audio & visible alarm at the same time.
There is an encoding circuit inside(No addressing required)When encoding, it can be directly connected to the alarm bus. When not encoding, a control module is required to use it.Coding circuit inside (may not code), can be connected in alarm bus directly when coded andmatched with module when not coded.
Technical Specifications|
Technical specifications
Working VoltageOperation voltage: DC18V~26V
power consumptionConsumption
Monitor currentMonitoring current 回路Loop:≤410uA; DC24V:≤6. 5mA
Action currentOperating current:回路Loop:≤1.5mA; DC24V:≤500mA
technical standardTechnical standard: EN54-3
sound pressure levelSounol Level: 90~120dB(3m)
Operating TemperatureOperation temperature: -25°C~70°C
relative humidityRelative humidity:≤95%
Overall dimensionsDimension: 239X120X91.5 mm2
weightWeight: 780g
colorColor:redRed
protection levelIPdegree: IP44
LR certified fire sound and light alarm CCS marine fire alarm system
materialMaterial: ABS
9-LoopFire alarm control panel(FACP)Replace
•Replace all repeater panels.
•Replace all detectors (smoke, heat, flame, multi-sensor).
•Replace all manual call points (including weatherproof and intrinsic safety types).
•Replace all interface modules and security barriers.
•Door handle magnet replacement
•Existing cabling infrastructure(9The loop should be preserved and reused (without the need to replace cables).
•target, aim at, address, focus on, in response to9Each loop unit completes the comprehensive reprogramming and address mapping of the system.
•System overall testing and debugging
•Submission of completion drawings and technical documents
•Training for ship crew on operation and maintenance.
3. Technical Requirements
•The addressable loop system operates at a voltage of24VDC.
•The fire alarm control panel should be configured to at least9An addressable circuit.
•with existing9Compatible with ring cabling infrastructure.
•Ship type approval(DNV /ABS/LROr equivalent certification).
•conform toSOLASrequirement.
• EN54Authentication component
•Battery backup capacity:24Hourly standby time+30Minute alarm status.
•The system integration capability covers: video data recording system(VDR)Public broadcasting and intercom system, whistle control system
Unified engine alarm and monitoring system, as well as local fire control panel.