- Phone
-
Address
No. 98-21 Nanping Road, Erqi District, Zhengzhou City
Zhongyuan Standard Material Center
No. 98-21 Nanping Road, Erqi District, Zhengzhou City
NameWater turbidity rapid measurement box
Number: ZWS301
Specification: Approximately 15 times of reagent usage
Supplier: Henan Detong Environmental Protection Technology Co., Ltd. (Zhongyuan Standard Material Center)
Water turbidity rapid measurement boxInstructions for Use
1. Detection significance: Drinking water with turbidity exceeding the national standard indicates that there are many impurities in the water, which may contain substances that are harmful to human health.
2. Method source: The method is derived from the national standard method. For the convenience of carrying and on-site use, standard suspensions are prepared using droppers.
3. Operation method: Take two turbidity tubes, one with 50ml of purified or distilled water and the other with 50ml of sample water. Observe the transparency of the two tubes from the side. If there is no difference between the two, the turbidity of the sample can be determined
qualified If the sample solution is turbid, add a standard suspension at 400 degrees Celsius (NTU) dropwise into a purified water pipe. After adding one drop per drop, shake well and compare it with the sample tube from the side until the turbidity is the same.
4. Result calculation and judgment: Each drop of standard suspension is equivalent to a turbidity (NTU) of 0.4. National standards stipulate that the turbidity of drinking water shall not exceed 1 degree (2.5 drops of standard suspension), and shall not exceed 3 degrees (7.5 drops of standard suspension) when limited by water sources and water purification technology conditions. Small centralized and decentralized water supply should not exceed 5 degrees Celsius (12.5 drops of standard suspension).
5. Remarks
5.1 The following method can also be used for the operation: first, use 50ml of purified water or distilled water, and prepare a standard suspension droplet to form a control tube with a standard degree as the measurement index. At this time, multiple samples can be compared and tested.
When the turbidity of the sample is greater than 10 degrees, the sample solution can be diluted before measurement, and the measurement result can be multiplied by the dilution factor.
6. Configuration: 10ml/bottle of standard suspension at 400 degrees Celsius (NTU), with 2 turbidity tubes.
7. Standard solution storage: A standard suspension at 400 degrees Celsius (NTU) should be stored at a temperature of 4 ° C to 8 ° C, with a shelf life of 12 months. It should be shaken well before use. The prepared standard tube solution should not be stored for a long time on the same day of use.
Apart from supplyWater turbidity rapid measurement boxThere are also water quality pigment rapid testing kits, hydrogen peroxide rapid testing kits, arsenic rapid testing kits, residual chlorine rapid testing kits, etc,For more details, please contact the supplier's customer service.
Welcome to Henan Detong Environmental Protection Technology Co., Ltd. (Zhongyuan Standard Material Center)!