Welcome Customer !

Membership

Help

Dongguan Liuqin Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Dongguan Liuqin Testing Instrument Co., Ltd

  • E-mail

    liuqin09@foxmail.com

  • Phone

    18028920280

  • Address

    No. 666, Beimen Village Industrial Zone, Qiaoli Village, Changping Town, Dongguan City

Contact Now

Walk in high and low temperature environment laboratory

NegotiableUpdate on 01/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Step in high and low temperature environment laboratory | High precision constant temperature and humidity laboratory refers to a temperature and humidity distribution that is relatively uniform, with a difference of 5-10 degrees between ordinary constant temperature and humidity chambers. However, the constant temperature and humidity laboratory assembled by Liuqin Technology has an error distribution within plus or minus 2 degrees, a fluctuation within plus or minus 0.5 degrees, a temperature analysis accuracy of 0.01 ℃, and a humidity analysis accuracy of 0.1% R.H
Product Details

Walk in high and low temperature environment laboratoryA high-precision constant temperature and humidity laboratory refers to a laboratory with a relatively dense distribution of temperature and humidity, similar to a regular constant temperature and humidity chamber5~10Degree error, andLiuqin TechnologyThe error distribution of the assembled constant temperature and humidity laboratory is positive and negative2Within the range of degrees, the fluctuation is positive or negative0.5Within degrees,Temperature analysis accuracy:0.01℃湿度解析精度:0.1%R.HTemperature control accuracy ±0.2℃Humidity control accuracy:±2%R.H.

They are suitable for testing various performance indicators of aerospace products, information electronic instruments and meters, electrical and electronic products, materials, various industrial products or electronic components in high and low temperature constant temperature or humid and hot constant humidity environments. High precision constant temperature and humidity laboratory | The control part of the high-precision constant temperature and humidity laboratory is designed on the right side of the equipment, equipped with temperature controllers, control switches, etc. It is easy to operate, simple, and easy to maintain. thislaboratorySelect high-quality materials and use current processing equipment to shape them.

Walk in high and low temperature environment laboratoryHigh precision constant temperature and humidity laboratoryProtection system:

1Overall equipment overheating;

2Fan overheating protection

3The overall equipment is out of phase/Reverse phase;

4Overload of refrigeration system;

5Refrigeration unit overpressure;

6Water shortage protection for humidification system;

7Overall equipment timing;

8Other protections include leakage, operation indication, automatic shutdown after fault alarm, etc.

High precision constant temperature and humidity laboratory | High precision constant temperature and humidity laboratoryUsage conditions:

1Installation site

The ground is flat and well ventilated

There is no strong vibration around the equipment

There is no strong electromagnetic field around the equipment

There are no flammable, explosive, corrosive substances or dust around the equipment

Leave appropriate space for use and maintenance around the equipment,

2Power supply conditions

Power requirements:AC380V±10% 50±0.5Hzthree-phase five-wire system

Pre installed power: total power+2.0KW

Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must be independently used for the equipment (recommended power switch capacity:32A

3Environmental conditions

Ambient temperature5℃~+30℃(24Average temperature within the hour ≤30℃)

ambient humidity:85%RH

2023步入式高低温试验室800.jpg