Welcome Customer !

Membership

Help

Shanghai Automation Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Automation Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 650 Lingshi Road, Jing'an District, Shanghai

Contact Now

WRN-122B High Aluminum Protective Tube Platinum Rhodium Thermocouple

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

WRN-122B high alumina protective tube platinum rhodium thermocouple is commonly used as a temperature sensor in conjunction with display instruments, recording instruments, and electronic regulators. It can directly measure the surface temperature of liquid, vapor, gas media, and solids in the range of 0 ℃ -1800 ℃ during various production processes.

Product Details

WRN-122B High Aluminum Protective Tube Platinum Rhodium ThermocoupleExplanation: According to national regulations, our factory has been producing platinum rhodium 30 platinum rhodium 10 platinum, nickel chromium nickel silicon, nickel chromium copper nickel, copper copper nickel, iron copper nickel and other types of thermocouples that comply with IEC standard division numbers since 1987. They should comply with JB/T9238-1999 standard. Our company's service tenet:

The company adheres to the principle of "serving customers, being responsible for customers, and satisfying customers", conscientiously implements the requirements of ISO9001 quality system standards, and continuously improves the product and service quality of the enterprise.

WRN-122B High Aluminum Protective Tube Platinum Rhodium ThermocoupleWorking principle: The working principle of a thermocouple is that two conductors with different compositions are welded at both ends to form a circuit. The direct temperature measuring end is called the measuring end, and the wiring end is called the reference end. When there is a temperature difference between the measurement and reference ends, a thermal current will be generated in the circuit. When connected to a display instrument, the instrument will indicate the corresponding temperature value of the thermoelectric potential generated by the thermocouple.

The thermoelectric potential of a thermocouple will increase as the temperature at the measuring end rises. The magnitude of the thermoelectric potential is only related to the material of the thermocouple conductor and the temperature difference between the two ends, and is independent of the length and diameter of the thermoelectric electrode.

Prefabricated thermocouples are mainly composed of a junction box, protective tube, insulating sleeve, terminal block, and thermoelectric device, and are equipped with various installation and fixing devices.

Main technical parameters

Temperature measurement range and allowable error

Thermocouple category

code name

graduation mark

Temperature measurement range

Allowable deviation △ t ℃

Platinum rhodium 30- Platinum rhodium 6

WRR

B

0-1800℃

± 1.5 ℃ or ± 0.0025 ∣ t ∣

铂铑10-铂

WRP

S

0-1600℃

± 1.5 ℃ or ± 0.0025 ∣ t ∣

Nickel chromium nickel silicon

WRN

K

0-1300℃

± 2.5 ℃ or ± 0.0075 ∣ t ∣

Nickel chromium copper nickel

WRE

E

0-800℃

± 2.5 ℃ or ± 0.0075 ∣ t ∣

Note that "t" refers to the measured temperature of the temperature sensing element.

Thermal response time

When there is a step change in temperature, the output of the thermocouple changes to 50% of the change, and the required time becomes the thermal response time, represented by T0.5.

Nominal pressure

Generally refers to the static external pressure that the protective tube can withstand at room temperature without breaking. In fact, the allowable working pressure is not only related to the material and diameter wall thickness of the protective tube, but also to its structural form, installation method, insertion depth, as well as the flow rate and type of the measured medium.

Thermocouple with the smallest insertion depth

It should not be less than 8-10 times the outer diameter of its protective tube (except for special products).

Thermocouple insulation resistance (at room temperature)

The test voltage for room temperature insulation resistance is DC 500V ± 50V. The atmospheric conditions for measuring room temperature insulation resistance are temperature 15 ℃~35 ℃, relative humidity 45%, and atmospheric pressure 86~106kPa.

a、 For thermocouples with a length exceeding 1 meter, the product of their insulation resistance at room temperature and their length should not be less than 100M Ω. m.

即: Rr. L≥100MΩ.m L>1m

b、 For thermocouples with a length of 1 meter or less, their insulation resistance at room temperature should not be less than 100M Ω.

Upper and lower temperature insulation resistance

The upper limit temperature insulation resistance of the thermocouple should not be less than the specified value in the table below:

Upper limit temperature tm ℃

Test temperature t ℃

Electric Sister Value M Ω

100≤tm<300

t=tm

10

300≤tm<500

t=tm

2

500≤tm<850

t=tm

0.5

850≤tm<1000

t=tm

0.08

1000≤tm<300

tm>1300

t=tm

t=1300

0.02

0.02

model

W

R

specification

content

R

Platinum rhodium 30- Platinum rhodium 6

P

铂铑10-铂

N

Nickel chromium nickel silicon

E

Nickel chromium copper nickel (nickel chromium constantan)

hot

electricity

Even materials

-

1

Non fixed device type

2

Fixed thread type

3

Active flange

4

Fixed flange type

5

Activity flange angle ruler form

6

Fixed thread conical protective tube type

Installation fixed form

3

waterproof type

4

Explosion proof type

junction box type

0

Φ 16mm protective tube

1

Φ 25mm protective tube (double-layer sleeve)

2

Φ 16mm high aluminum pipe (single-layer sleeve)

3

Φ 20mm high alumina pipe

Design Serial Number

stainless steel

W

R

-

B

Unified specifications, models, and specifications

Thermocouple category

Product model

graduation mark

Temperature measurement range ℃

specification

Thermal response time T0.5S

diameter

Protective tube material

Single Platinum Rhodium 30- Platinum Rhodium 6

WRR-120B

B

(LB-2)*

0~1600

φ16

Jadeite quality

<150

WRR-121B

φ25

<360

Double Platinum Rhodium 30 Platinum Rhodium 6

WRR2-120B

φ16

<150

WRR2-121B

φ25

<360

Single Platinum Rhodium 10 Platinum

WRP-120B

S

(LB-3)*

0~1300

φ16

High alumina

<150

WRP-121B

φ25

<360

Double platinum rhodium 10 platinum

WRP2-120B

φ16

<150

WRP2-121B

φ25

<360

Single nickel chromium nickel silicon

WRN-122B

K

(EU-3)*

0~1100

φ16

High alumina

<240

WRN-123B

0~1200

φ20

Double branch nickel chromium nickel silicon

WRN2-123B

0~1100

Single Platinum Rhodium 30- Platinum Rhodium 6

WRR-130B

B

(LL-2)*

0~1600

φ16

Jadeite quality

<150

<360

<150

<360

WRR-131B

φ25

Double Platinum Rhodium 30 Platinum Rhodium 6

WRR2-130B

φ16

WRR2-131B

φ25

Single Platinum Rhodium 10 Platinum

WRP-130B

S

(LB-3)*

0~1300

φ16

High alumina

150

<360

<150

<360

WRP-131B

φ25

Double platinum rhodium 10 platinum

WRP2-130B

φ16

WRP2-131B

φ25

Order this product

Our company's after-sales service commitment:

If users encounter any problems while using the products provided by our company, they can receive support and assistance. Users can primarily communicate with our company's customer service center. Once a user's request is received, professional engineers from the customer service department will solve or answer the questions raised by the user within the specified time. In addition, our company has 24-hour after-sales service to ensure a response within 24 hours after receiving user notifications. For those that require personnel to handle, the company will dispatch service personnel to the scene within a reasonable time to ensure that the equipment can resume normal operation as soon as possible.

Related Products

  • WRNG-440 High Temperature and High Pressure Thermocouple
  • High temperature precious metal thermocouple WRP-130, high temperature thermocouple WRP-130
  • High temperature platinum rhodium thermocouple, high temperature precious metal thermocouple, high temperature thermocouple model
  • High temperature precious metal thermocouple WRP-131, platinum rhodium thermocouple WRP-131, platinum rhodium thermocouple temperature measurement range
  • WRE2G-440 high temperature and high pressure thermocouple, WRE2G-440 thermocouple
  • High temperature precious metal thermocouple
  • WRP-100 Platinum Rhodium Thermocouple
  • WRR-130 Platinum Rhodium Thermocouple, WRR-130 Parameters, WRR-130 Price
  • Armored platinum rhodium thermocouple
  • Dual platinum rhodium thermocouple model, WRR dual platinum rhodium