Overview

The pressure spring fixed thermocouple is used in conjunction with display instruments and can directly measure temperatures within the range of 0-400 ℃. With flexible extension wires that can be bent freely, it has the characteristics of small thermal response time and easy use, and is suitable for industries such as plastic extruders, textiles, and food.

Product Details

1Pressure spring fixed thermocouplestructural principle


Pressure spring fixed thermocoupleThe working principle, division characteristics and allowable deviation, temperature compensation of the reference end (cold junction), and connection method with the display measuring instrument are all the same as those of general thermocouples. The structure consists of protective tubes and installation bolts Composed of locking sleeve, spring, and thermocouple wire.


2Main technical parameters

Accuracy level: Level I or Level II


Thermal response time: ≤ 5 seconds

3Model

The WRET-01 pressure spring fixed nickel chromium copper nickel thermocouple uses a pressure spring to tightly adhere the thermocouple end to the surface of the measured object, in order to improve the reliability and accuracy of the measurement. It is used in conjunction with display instruments and can directly measure temperatures within the range of 0-400 ℃. Thermocouples come with flexible extension wires that can be bent freely, have a small thermal response time, and are easy to use. They are suitable for industries such as plastic extrusion, textile, and food.


structural principle


The working principle, division characteristics, allowable deviation, reference end (cold junction) temperature compensation, and connection method with display measuring instruments of WRET-01 thermocouple are the same as those of general thermocouples.


The structure of WRET-01 thermocouple is shown in the figure, consisting of protective tube, mounting bolt, locking sleeve, spring, and thermal resistance wire.


Specifications


Technical Specifications


Installation method


The installation method of WRET-01 thermocouple is shown in the figure. It is fixedly installed on the measured object. First, tighten the connecting bolts on the measured object, then tightly attach the thermocouple to the measured object, tighten the sleeve screws, and finally tighten the locking sleeve.


Model


Model

graduation mark

Measurement range ℃

Thermal response time t0.5

Protective tube material

WRET-01

E(EA-2) ﹡

0~400

<5

stainless steel

1Cr18Ni9T

specification

Connecting bolt L2mm

Total length Lmm

Protective tube L1mm

1000

1500

2000

2500

3000

3500

4000

30

30

30

30

30

30

30

35 or 70

1000

1500

2000

2500

3000

3500

4000

60

60

60

60

60

60

60







Note: Ordering must include 1) product name and model

2) Total length and placement depth (L × 12 × 12)

3) The division mark marked with "*" indicates a special specification order.