E-mail
shibo.yang@szhcj.cn
-
Phone
13671568405
-
Address
Room 301, Building 3, No. 1128 Changjiang South Road, Kunshan Development Zone, Jiangsu Province
Suzhou Huichangjin Electromechanical Equipment Co., Ltd
shibo.yang@szhcj.cn
13671568405
Room 301, Building 3, No. 1128 Changjiang South Road, Kunshan Development Zone, Jiangsu Province
Product specifications:Fluke FLUKEVibration testerSeismometer
technical indicators
Low frequency range (direct frequency measurement)10 Hz to 1000 Hz
High frequency range (CF+measurement)4000 Hz to 20000 Hz
Severity levelGood, average, not meeting requirements, unacceptable
Vibration limit50 g peak (100 g maximum peak)
A/D conversion16 bits
signal-to-noise ratio80 dB
sampling rateLow frequency: 20000 Hz
High frequency: 80000 Hz
Real time clock backupButton cell
sensor
sensitivity100 mV g ± 10%
measurement range0.01 g to 50 g
Low frequency range (direct frequency measurement)10 Hz to 1000 Hz
High frequency range4000 Hz to 20000 Hz
resolution0.01 g
precisionWithin the range of 100 Hz ± 5% of the measured value
Amplitude unit
accelerationg, m/sec²
speedin/s, mm/s
displacementmils, mm
Infrared thermometer (temperature measurement)
range-20 ° C to 200 ° C (-4 ° F to 392 ° F)
precision±2 °C (4 °F)
focal lengthFixed, approximately 3.8 cm (1.5 ")
external sensor
Note: Fluke supports but does not provide external sensors
frequency range10 Hz to 1000 Hz
Bias voltage (to power supply)20 V to 22 V DC
Bias current (to power supply)5 mA maximum value
firmware
external interfaceUSB 2.0 (full speed) communication interface
data capacityDatabase on built-in flash memory
upgradeThrough USB socket
memoryMore than 3500 measurement results
radiation
Electrostatic discharge: burstStandard EN 61000-4-2
electromagnetic interferenceStandard EN 61000-4-3
radiationStandard CISPR 11 Level A
Environmental Requirements
Operating Temperature-20 ° C to 50 ° C (-4 ° F to 122 ° F)
storage temperature-30 ° C to 80 ° C (-22 ° F to 176 ° F)
Operating Humidity10% to 95% relative humidity (non condensing)
Operating/Storage Height3048 m (10000 ft) altitude
IP ratingIP54
Vibration limit500g peak value
drop test1-meter drop
General technical indicators
Battery TypeAA (2-cell) lithium iron disulfide battery
Battery life250 measurements
Dimensions (length x width x height)24.1 cm x 7.1 cm x 5.8 cm
(9.5 in x 2.8 in x 2.3 in)
weight0.40 kg (0.89 lb)
connectorUSB mini-B 7-pin, external sensor socket (SMB type connector)
Fluke 805 FC vibration point tester
include:
Fluke 805 FCVibration tester
USB cable
storage box
Belt type protective sheath
Quick Reference Guide
CD-ROM (including MS Excel template and manual)
Two (2) AA batteries