Vertical constant temperature shaker NS-2102 double door oscillating incubator

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The vertical constant temperature shaker NS-2102 double door oscillation incubator is an intelligent constant temperature cultivation shaker used for bacterial culture, fermentation, hybridization, biochemical reactions, fermentation, and cell tissue research that require high temperature, oscillation frequency, and amplitude. It plays an important role in research and application fields such as medicine, biology, molecular biology, pharmaceuticals, food, and environmental protection.
Product Details

Vertical constant temperature shaker NS-2102 double door oscillating incubator

Main features:

1. Built in drive system ensures smooth, stable, durable, and reliable operation of the machine.

2. Integral negative feedback control technology ensures the accuracy and reliability of speed and temperature.

3. Intelligent sound and light alarm environment scanning microprocessor controller. It has self stop protection, self diagnosis, and safety alarm functions when opening the lid.

4. Large screen background light LCD display screen, Chinese subtitle human-machine dialogue prompt function, while displaying measured values, set values, and machine operating status.

5. The full temperature constant temperature cultivation shaker can operate with parameters that can be memorized and protected. The power supply unexpectedly loses power, and automatically resumes operation according to the original set program after receiving a call.

6. Run parameters with password lock to avoid human error. Illumination and UV disinfection functions.

7. Automatic power-off protection device for motor overheating and temperature runaway.

8. The timer is 999 hours, and the LCD screen displays the set time and remaining time.

9. The slow start design prevents the splashing of shaking bottle liquid caused by sudden start, effectively ensuring the accuracy of quantitative experiments.

10. Intelligent refrigeration frost free operation technology can enable equipment to operate stably for a long time at low temperatures.

11. Electronic enclosed adjustable closed loop heating and cooling system. The fan design and forced convection method ensure good temperature control effect.

12. Streamlined, mirrored stainless steel lining and cavity components, tilted humanized control panel.

立式恒温摇床NS-2102双门振荡培养箱

As a commonly used laboratory instrument and equipment, laboratory shaker requires regular daily maintenance and upkeep to ensure its normal operation and extend its service life. The following are the daily maintenance and upkeep steps for laboratory shaker:
1. Cleaning: Regularly clean the surface and internal parts of the laboratory shaker, which can be wiped with a clean cloth or soft brush. Avoid using corrosive or abrasive cleaning agents to prevent damage to the equipment.
2. Check fasteners: Regularly check whether the screws, bolts, and other fasteners on the laboratory shaker are loose. If they are loose, they should be tightened in a timely manner.
3. Lubrication: The laboratory shaker may require lubrication of certain components such as bearings and rocker arms during operation. According to the equipment manual, choose the appropriate lubricant for lubrication to avoid excessive use of lubricants.
4. Check the power cord and plug: Regularly inspect the power cord and plug of the laboratory shaker for damage, aging, or looseness. If any problems are found, they should be replaced or repaired immediately.
5. Temperature and humidity control: Keep the temperature and humidity in the laboratory within an appropriate range, and avoid exposing the shaker to high temperature or high humidity environments to avoid affecting the normal operation and lifespan of the equipment.
6. Pre operation inspection: Before each use of the laboratory shaker, the various functions of the equipment should be checked for normal operation. Ensure that all control buttons, switches, displays, etc. are functioning properly.
7. Regular maintenance: Conduct regular maintenance work according to the equipment manual. This may include replacing worn parts, cleaning or replacing filters, calibrating sensors, etc.


shakeBed(oscillationdeviceAs a laboratorycommonly usedequipmentIts applicationwide range, coveringMultiple Sciencesandindustrial sectorThe following isIts main applicationsscenedetailed classification
1.lifeScience andmedicine研究
cell culture
Used for suspensionCell(Like breastfeedinganimal cellInsectsCells)The cultivation,passgentleOscillatory promotionoxygenAnd nutritionThe uniformity of matterDistribution,Avoid cellsSedimentation.
for example: HybridTumor cellscultivatevaccinesR&D.
microorganismcultivate
bacteriaYeastwaitmicrobialliquid culture(such asLB medium), oscillationincreasedissolved oxygenQuantity,accelerateGrowth.
applicationscene: AntibioticsproductionGeneengineered bacteriaexpandIncrease.
DNA/RNAextract
cooperate, coordinate, collaboratesplitDissolving reagents, throughOscillatory promotionAll samples areQualitative transformation, improvenucleic acidextraction efficiency.
immunitylearnexperiment
enzymeallyImmune adsorptionExperiment(ELISA)In the middleWash the boardstepsOscillation incubationEducation,Or antibodies Antigen bindingreactivemix.

2.chemistryRegarding materialsscience
Chemical reaction acceleration
mixreactionThe object(Like liquid phaseSynthesiscatalytic reaction), throughoscillationimprove reaction速率和uniformity.
For example:nanomaterialsSynthesispolymerAggregation.
solvent extraction
LiquidliquidDuring the extraction process, oscillationPromote twoMixed together, improvetarget objecttransferefficiency
Before the sampleprocess
solidSample(soilPlantsorganizationofoscillationextractforfollow-upchromatographyOr spectrumanalyze

3. environmental monitoringandagriculture
Environmental samplesanalyze
watersampleSoilThe pollutants inheavy metalOrganicPollutant)extractLike EPAstandard methodThe oscillation in the middleextraction.
seedsproutexperiment
Simulate natureConditional oscillation, 研究The seeds are indynamicIn the environmentgerminateRate.
compost研究
passOscillatory promotionorganicThe object'suniformdecomposeoptimizeenhanceimproverefine



立式恒温摇床NS-2102双门振荡培养箱


heap

Fertilizer process

.

Vertical constant temperature shaker NS-2102 double door oscillating incubator

Technical Specifications

model

NS-2102C

NS-2102

NS-2112B

Rotation frequency

40~300rpm

40~280rpm

Frequency accuracy

±1rpm


Oscillation amplitude

Ф26mm

Ф35mm

reachable capacity

100ml×48 250ml×30

500ml×24 1000ml×12

250ml×70 500ml×48

1000ml×30

250ml×90 500ml×74

1000ml×48

Standard Configuration

250ml×30

250ml×35 500ml×24

250ml×45 500ml×36

pallet dimensions

500×350mm

740×460mm

970×560mm

timing range

0-999hour

Temperature control range/accuracy

4-60 ℃ (room temperature 25 ℃)/± 0.1 ℃

Temperature Uniformity

± 1 ℃ (37 ℃ constant temperature state)

display mode

LCD (Liquid Crystal Display)

Quantity of pallets

2 pieces

Overall dimensions

700×560×1260mm

950×700×1260mm

1200×800×1500mm

power

1100W

1450W