Welcome Customer !

Membership

Help

Shenzhen Grechuang Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shenzhen Grechuang Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    816, Jinfulai Building, No. 49-1 Dabao Road, Baocheng District 28, Bao'an, Shenzhen

Contact Now

Vatell Heat Flow Meter-TG-1000-0

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Vatell heat flux meter TG-1000-0 belongs to the "Gardon Gauge" total heat flux sensor, which can continuously measure the total heat flux density of "radiation+convection". The nVatell TG-1000 heat flow meter is a "water-cooled round foil total heat flow sensor" with ultra wide range, millisecond response, and long-term stability, suitable for 5-5000 W cm ⁻; #178; Research and industrial thermal testing in high heat flux density areas.

Product Details

Vatell heat flow meter TG-1000-0Belonging to the "Gardon Gauge" total heat flux sensor, it can continuously measure the "radiation+convection" total heat flux density and is commonly used in aviation engines

High heat flow environments such as space re-entry and combustion chambers. The core features and parameters are as follows:

Vatell-热流计-TG-1000-0


working principle0.312-inch circular copper foil is welded to the center of the copper heat sink; The heat flow causes a radial temperature gradient in the foil, and the temperature difference between the center and edge of the foil is measured by an embedded thermocouple,

The output thermoelectric potential is proportional to the heat flux density, with good linearity and almost no influence from surface temperature.

Vatell-热流计-TG-1000-0

Structure and CoolingThe main body is water-cooled and continuously cooled, which can be exposed to high heat flux for a long time without any "maximum measurement time" limit; The sensor housing and heat sink are both made of copper, ensuring high thermal conductivity and heat capacity,

Suppress zero drift. Main technical parameters (typical values) Range: 0-5 W cm ⁻ ² (low) to 0-5 000 W cm ⁻ ² (high) Sensitivity: ≈ 2 mV/(W cm ⁻ ²) Calibration accuracy: ± 3% Repeatability: 1% Response time: millisecond level (naturally fast round foil structure) Working surface temperature: ≤ 300 ° C (maintained by water cooling) Installation size: φ 7.9 mm × 25 mm (standard head)

Vatell-热流计-TG-1000-0


Typical ApplicationsAerospace wind tunnel/plasma arc heater: Re entry thermal protection test, thermal distribution mapping of aircraft engine combustion chamber and booster cylinder, transient/steady-state thermal assessment of rocket injection panel, gas rudder, etc. can be used as the "total heat flux" benchmark, and used in conjunction with Vatell TG-9000 radiometer to provide radiation and convection components respectively.

Key points for useClean closed-loop water cooling (flow rate ≥ 0.3 L min ⁻¹, water temperature ≤ 30 ° C) must be used, otherwise it is easy to cause reading drift due to vapor film. The head should be installed flush with the surface of the model, and misalignment>0.2 mm will introduce errors in convective "suction/blowing". After each hot test, a "zero point recheck" should be performed - record the output under no heat flow conditions, and recalibrate if the drift is greater than 1%. Factory calibration of graphite rod radiation source based on NIST traceability; If there are significant differences in the working frequency band or gas composition (such as rich combustion gas containing carbon smoke), it is recommended to perform comparative calibration on site. In shortVatell TG-1000 heat flow meterIt is a "water-cooled round foil total heat flux sensor" with ultra wide range, millisecond response, and long-term stability, suitable for 5-5000 W cm ⁻ ²

Research and industrial thermal testing in high heat flux density areas.