Principle of V5-T tension control dedicated frequency converter
Currently, more and more industries require frequency converters to achieve control over the winding and unwinding of pipes and wires during processing. The control of the V5-T winding and unwinding dedicated frequency converter achieves PID regulated tension control speed mode by setting the external line speed and reflecting the feedback signal of the current winding and unwinding tension swing rod, so that the tension swing rod is always in a balanced position to achieve constant tension winding and unwinding control.
The V5-T frequency converter is based on high-performance vector control technology and can provide stable and continuous torque output throughout the entire speed range when used in conjunction with the host's stretching or traction drive. It also has super strong overload capacity and trip free operation; When controlling the unwinding and unwinding, the tension swing rod can quickly reach the equilibrium position at any position, and high-speed operation can also maintain stable unwinding and unwinding effects.
Technical characteristics of V5-T frequency converter
Easy to install and use, no need to change the control mode, mechanical and circuit structure of the original equipment.
Strong resistance to current shock, excellent vector control characteristics ensure continuous and stable operation without tripping, and can overload for 0.5 seconds at 200%.
◆ Super strong low-speed load and fast speed regulation capability, large torque output when threading, the system can quickly reach the high-speed operation set by the system.
High power factor output, reduced reactive power loss, and no high current surge during soft start.
The standard configuration keyboard can achieve parameter copying function, eliminating the need for repetitive and cumbersome function settings.
◆ Provides multiple empty roll settings and flexible and easy selection. The current roll diameter can be automatically or manually cleared, and can be automatically memorized when the machine is stopped or powered off.
Provide multiple methods for setting system line speeds and accumulating roll diameters.
|
voltage level |
model |
Single/three-phase 200V constant torque/heavy load application |
|||||
Suitable motor (kW) |
Rated output current (A) |
Rated input current (A) |
|||||
400V |
V5/V6−T−4T0.75 |
0.75 |
2.5 |
2.8 |
1.5 |
3.3 |
3.6 |
V5/V6−T−4T1.5 |
1.5 |
3.8 |
4.2 |
2.2 |
5.0 |
5.5 |
|
V5/V6−T−4T2.2 |
2.2 |
5.5 |
6.1 |
3.7 |
7.5 |
8.3 |
|
V5/V6−T−4T3.7 |
3.7 |
9 |
10 |
5.5 |
11 |
12 |
|
V5/V6−T−4T5.5 |
5.5 |
13 |
15 |
7.5 |
17 |
19 |
|
V5/V6−T−4T7.5 |
7.5 |
17 |
19 |
11 |
22 |
25 |
|
V5/V6−T−4T11 |
11 |
24 |
26 |
15 |
30 |
33 |
|
V5/V6−T−4T15 |
15 |
30 |
33 |
18.5 |
37 |
40 |
|
V5/V6−T−4T18.5A* |
18.5 |
39 |
43 |
22 |
44 |
50 |
|
V5/V6−T−4T22A |
22 |
45 |
53 |
30 |
56 |
62 |
|
V5/V6−T−4T30A |
30 |
60 |
66 |
37 |
72 |
80 |
|
V5/V6−T−4T37A |
37 |
75 |
83 |
45 |
91 |
100 |
|
V5/V6−T−4T45A |
45 |
91 |
100 |
55 |
110 |
121 |
|
V5/V6−T−4T55A |
55 |
112 |
123 |
75 |
142 |
156 |
|
V5/V6−T−4T75A |
75 |
150 |
165 |
90 |
176 |
194 |
|
V5/V6−T−4T90 |
90 |
176 |
160 |
110 |
210 |
196 |
|
V5/V6−T−4T110 |
110 |
210 |
196 |
132 |
253 |
232 |
|
V5/V6−T−4T132 |
132 |
253 |
232 |
160 |
304 |
282 |
|
V5/V6−T−4T160 |
160 |
304 |
282 |
185 |
350 |
326 |
|
V5/V6−T−4T185 |
185 |
350 |
326 |
200 |
380 |
352 |
|
V5/V6−T−4T200 |
200 |
380 |
352 |
220 |
426 |
385 |
|
V5/V6−T−4T220 |
220 |
426 |
385 |
250 |
470 |
437 |
|
V5/V6−T−4T250 |
250 |
470 |
437 |
280 |
520 |
491 |
|
V5/V6−T−4T280 |
280 |
520 |
491 |
315 |
600 |
580 |
|
V5/V6−T−4T315 |
315 |
600 |
580 |
355 |
650 |
624 |
|
V5/V6−T−4T355 |
355 |
650 |
624 |
400 |
690 |
670 |
|
V5/V6−T−4T400 |
400 |
690 |
670 |
450 |
775 |
755 |
|
V5/V6−T−4T450 |
450 |
775 |
755 |
500 |
860 |
840 |
|
V5/V6−T−4T500 |
500 |
860 |
840 |
450 |
950 |
920 |
|
Control method |
High performance vector control tension control |
power range |
0.75kW~500 kW |
Input voltage and frequency |
3AC 380V~480V; 50Hz/60Hz |
output voltage |
3AC 0~rated input voltage |
output frequency |
0.0~300.0Hz |
Digital Input/Output |
Standard multifunctional input terminal, expandable Standard open collector output, expandable |
Analog input/output |
Input: AI1 0-20 mA, input impedance 500 Ω, maximum input current 30mA; 0~10V, Input impedance 20k Ω, Maximum input voltage 15V, resolution of 12 bits (0.025%) Select 0-20 mA or 0-10V analog input through jumper wires AI2 as above AI3 −10V~10V, Input impedance 20k Ω, maximum input voltage ± 15V, resolution of 12 bits (0.025%) Output: AO1 0-20 mA, allowable output impedance of 200-500 Ω 0~10V, Output allowable impedance ≥ 10k Ω, resolution of 10 bits (0.1%) There is a short-circuit protection function, and the analog output of 0-20 mA or 0-10V can be selected through jumper wires AO2 as above |
Pulse input/output |
Pulse input: 0.1Hz~50kHz; Voltage range: 24V ± 20% Pulse output: 0-50kHz; Voltage range: 24V ± 20% |
communication protocol |
The dual 485 communication interface supports Modbus protocol (RTU), and the standard operation panel can achieve remote control box function up to 500 meters away |
brake unit |
Standard built-in for models with a power range of 15kW and below; Built in optional power range of 18.5kW to 75kW; Power ranges of 90kW and above require external installation |
external interface |
DC24V power supply, maximum output current 100 mA |
DC reactor |
Models with a power range of 90kW and above come standard with an external DC reactor |
Installation method |
wall-mounted installation |
Protection level |
IP20 |
Power levels of V5-T-4T7.5 and below
V5-T-4T11 and above power levels
The appearance, installation dimensions, and approximate weight of the product
|
voltage level |
Inverter model |
Appearance and installation dimensions (mm) |
approximately weight (kg) |
|||||||
W |
H |
D |
W1 |
H1 |
D1 |
T1 |
Installation hole d |
|||
400V |
V5/V6−T−4T0.75 |
118 |
190 |
155 |
105 |
173 |
40.8 |
3 |
5.5 |
1.5 |
V5/V6−T−4T1.5 |
118 |
190 |
175 |
105 |
173 |
60.5 |
4 |
5.5 |
2.6 |
|
V5/V6−T−4T2.2 | ||||||||||
V5/V6−T−4T3.7 | ||||||||||
V5/V6−T−4T5.5 |
155 |
249 |
185 |
136 |
232 |
69 |
8 |
5.5 |
3 |
|
V5/V6−T−4T7.5 | ||||||||||
V5/V6−T−4T11 |
210 |
337 |
200 |
150 |
324 |
107.5 |
2.5 |
7 |
8.5 |
|
V5/V6−T−4T15 | ||||||||||
V5/V6−T−4T18.5A* |
285 |
440 |
220 |
200 |
425 |
107.5 |
2.5 |
7 |
17 |
|
V5/V6−T−4T22A | ||||||||||
V5/V6−T−4T30A | ||||||||||
V5/V6−T−4T37A |
315 |
575 |
227 |
220 |
553 |
123.5 |
2.5 |
10 |
25 |
|
V5/V6−T−4T45A | ||||||||||
V5/V6−T−4T55A |
400 |
615 |
265 |
270 |
590 |
123.5 |
3.0 |
10 |
35 |
|
V5/V6−T−4T75A | ||||||||||
V5/V6−T−4T90 |
465 |
745 |
325 |
343 |
715 |
156 |
3.0 |
12 |
55 |
|
V5/V6−T−4T110 | ||||||||||
V5/V6−T−4T132 |
540 |
890 |
385 |
370 |
855 |
205.5 |
4.0 |
14 |
85 |
|
V5/V6−T−4T160 | ||||||||||
V5/V6−T−4T185 | ||||||||||
V5/V6−T−4T200 | ||||||||||
V5/V6−T−4T220 |
700 |
1010 |
385 |
520 |
977 |
210 |
4.0 |
14 |
125 |
|
V5/V6−T−4T250 | ||||||||||
V5/V6−T−4T280 | ||||||||||
V5/V6−T−4T315 |
810 |
1358 |
425 |
520 |
1300 |
210 |
4.0 |
14 |
215 |
|
V5/V6−T−4T355 | ||||||||||
V5/V6−T−4T400 |
810 |
1358 |
425 |
520 |
1300 |
210 |
4.0 |
14 |
215 |
|
V5/V6−T−4T450 | ||||||||||
V5/V6−T−4T500 | ||||||||||