feature
■ This frequency converter is equipped with a touch screen for faster operation and more intuitive and comprehensive display according to the requirements.
■ Excellent control performance under sensorless vector control, precise speed identification and rotor flux orientation, and fast response and stable operation of torque even during sudden load changes at 0.25Hz.
■ Excellent current and voltage control technology, repeatedly alternating acceleration and deceleration with 0.1s instructions, ensuring stable and trip free operation of the frequency converter.
■ Independent air duct design: The entire series supports the application requirements of installing radiators outside the cabinet, suitable for environments with high cotton or dust content such as spinning machines and wire drawing machines.
■ Wide voltage range design: The DC working voltage range is DC 360-720V, and it also has the function of recording grid voltage fluctuations.
Typical industries
Such as fans, water pumps, stone machinery, extruders, large circular machines, fine wire drawing machines, air compressors, plastic blow molding machines, mining winches, belt conveyors, oil pumps, ceramic machinery, as well as mid-range applications that meet open-loop vector control.
Like Nanhua Sugar Industry
|
voltage level |
model |
constant torque/Heavy-duty use |
Variable torque/Light load application |
|||||
|
Adapted motor (kW) |
rated output Current(A) |
Rated input Current(A) |
Adapted motor (kW) |
rated output Current(A) |
Rated input Current(A) |
|||
|
three-phase 400V |
V5−H−4T315G−GS |
315 |
600 |
552 |
− |
− |
− |
|
V5−H−4T355G−GS |
355 |
650 |
624 |
355 |
650 |
624 |
||
V5−H−4T400G−GS |
400 |
690 |
670 |
400 |
690 |
670 |
||
V5−H−4T450G−GS |
450 |
775 |
755 |
450 |
775 |
755 |
||
V5−H−4T500G−GS |
500 |
860 |
840 |
500 |
860 |
840 |
||
V5−H−4T560G−GS |
560 |
950 |
920 |
560 |
950 |
920 |
||
V5−H−4T630G−GS |
630 |
1100 |
1050 |
630 |
1100 |
1050 |
||
V5−H−4T710G−GS |
710 |
1300 |
1248 |
710 |
1250 |
1200 |
||
V5−H−4T800G−GS |
800 |
1380 |
1340 |
800 |
1380 |
1340 |
||
V5−H−4T900G−GS |
900 |
1550 |
1510 |
900 |
1550 |
1510 |
||
V5−H−4T1000G−GS |
1000 |
1720 |
168 |
1000 |
1720 |
1680 |
||
V5−H−4T1250G−GS |
1250 |
2200 |
2100 |
1250 |
2200 |
2100 |
||
Control method |
Open-loop vector control; |
power range |
315kW~1200 kW |
|
Input voltage frequency |
3AC380V~480V;50Hz/60Hz |
output voltage |
3AC 0Rated input voltage |
output frequency |
0.0~300.0Hz |
|
digital input output |
Standard multifunctional input terminal, expandable Standard open collector output, expandable |
|
Analog input output |
Input:AI1 0~20 mAInput impedance500Ω, maximum input current30mA; 0~10VInput impedance20kΩ, maximum input voltage15VThe resolution is12Position(0.025%) Select through jumper wires0~20 mAor0~10VAnalog input quantity AI2Ditto. AI3 −10V~10VInput impedance20kΩMaximum input voltage±15VThe resolution is12Position(0.025%) output:AO1 0~20 mAOutput allowable impedance200~500Ω 0~10VOutput allowable impedance ≥10kΩThe resolution is10Position(0.1%) There is a short-circuit protection function, which can be selected through jumper wires0~20 mAor0~10VAnalog output quantity AO2Ditto. |
Pulse input/output |
Pulse input:0.1Hz~50kHzVoltage range:24V±20% Pulse output:0~50kHzVoltage range:24V±20% |
communication protocol |
double485Communication interface supportModbusAgreement(RTU),The standard operation panel can achieve remote control box function, the farthest500rice |
external interface |
DC24VPower supply, maximum output current100 mA |
reactor |
Standard built-in input reactor, optional output reactor |
Installation method |
Vertical installation |
Protection level |
IP20 |
Optional accessories/expansion card
category |
name |
model |
Functional Description |
reference |
control panel |
Text display |
EX−MT01 |
Optional human-machine interface - text display |
P2−** |
touch screen |
EX−MT02 |
Standard human-machine interface - touch screen |
P2−** |
|
expansion card |
Power monitoring card |
EX−PA01 |
Three phase input power supply is missing phase/Instantaneous power outage monitoring |
P2−** |
Phase sequence detection card |
EX−PA02 |
Phase sequence detection of three-phase input power supply |
P2−** |
|
Speed tracking card |
EX−PA03 |
Realize speed tracking |
P2−** |
|
External power rectifier card |
EX−RF01 |
The control power is provided by an external power source |
P2−** |
|
programmableCANBus expansion card |
EX−CA05 |
P2−** |
||
Profibus DPcommunication card |
EX−CA06 |
P2−** |
V5−H−4T315G−GSPower levels and aboveV5−H−4T400G−GSPower level and above
|
voltage level |
Inverter model |
Appearance and installation dimensions(mm) |
Approximately weight(kg) |
Remarks |
||
W |
H |
D |
||||
400V |
V5−H−4T315G−GS |
800 |
2315 |
600 |
430 |
stand-alone |
V5−H−4T355G−GS |
440 |
stand-alone |
||||
V5−H−4T400G−GS |
450 |
stand-alone |
||||
V5−H−4T450G−GS |
1000 |
2352 |
600 |
480 |
stand-alone |
|
V5−H−4T500G−GS |
480 |
stand-alone |
||||
V5−H−4T560G−GS |
500 |
stand-alone |
||||
V5−H−4T630G−GS |
520 |
stand-alone |
||||
V5−H−4T710G−GS |
1250 |
2352 |
600 |
650 |
stand-alone |
|
V5−H−4T800G−GS |
2000 |
2352 |
600 |
920 |
parallel operation V5−H−4T450G−GS*2 |
|
V5−H−4T900G−GS |
980 |
parallel operation V5−H−4T500G−GS*2 |
||||
V5−H−4T1000G−GS |
1000 |
parallel operation V5−H−4T560G−GS*2 |
||||
V5−H−4T1250G−GS |
1060 |
parallel operation V5−H−4T630G−GS*2 |
||||