E-mail
lhht@v-t.net.cn
- Phone
-
Address
Kono Building, Kono Industrial Park, No. 7 Tongguan Avenue, Guangming District, Shenzhen
Shenzhen Blue Ocean Huateng Technology Co., Ltd
lhht@v-t.net.cn
Kono Building, Kono Industrial Park, No. 7 Tongguan Avenue, Guangming District, Shenzhen
V5/V6−MA−4T □□□G three-phase400Vconstant torque/Heavy-duty use
Power(kW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
||
|
Adapted motor Power(kW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
||
lose |
Voltage(V) |
3phase0Rated input voltage |
|||||||||||||
|
rated Current(A) |
2.5 |
3.8 |
5.5 |
9 |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
||
|
overload ability |
150% 1minute,180% 10In seconds,200% 0.5Seconds, intervals 10Minutes (inverse time characteristic) |
||||||||||||||
lose |
rated voltage/frequency |
3phase380V~480V;50Hz/60Hz |
|||||||||||||
|
allow voltagescope |
323V~528VVoltage imbalance:≤3%Allow frequency fluctuations:±5% |
||||||||||||||
|
rated Current(A) |
2.8 |
4.2 |
6.1 |
10 |
15 |
19 |
26 |
33 |
43 |
50 |
66 |
83 |
100 |
||
brake unit |
Standard built-in |
||||||||||||||
Protection level |
IP20 |
||||||||||||||
cooling method |
Self cooling |
forced air cooling |
|||||||||||||
V5/V6−MA−2T □□□G single/three-phase200Vconstant torque/Heavy-duty use
Power(kW) |
0.4 |
0.75 |
1.5 |
2.2 |
|
Adapt motor power(kW) |
0.4 |
0.75 |
1.5 |
2.2 |
|
lose |
Voltage(V) |
3phase0Rated input voltage |
|||
Rated current(A) |
3 |
5 |
7.5 |
10 |
|
overload capacity |
150% 1minute,180% 10In seconds,200% 0.5Seconds, intervals 10Minutes (inverse time characteristic) |
||||
lose |
rated voltage/frequency |
3Phase or single-phase200V~240V;50Hz/60Hz |
|||
|
allow voltage range |
180V~260VVoltage imbalance:≤3%Allow frequency fluctuations:±5% |
||||
Rated current(A) |
3.8 |
5.5 |
8.3 |
12 |
|
brake unit |
Standard built-in |
||||
Protection level |
IP20 |
||||
cooling method |
Self cooling |
forced air cooling |
|||
|
control manufacture special sex |
Control method |
Open loop vector control (without encoder) |
Closed loop vector control (with encoder) |
starting torque |
0.25Hz 180% |
0.00Hz 180% |
|
speed regulation range |
1:200 |
1:1000 |
|
Steady speed accuracy |
± 0.2% |
± 0.02% |
|
torque control |
have |
have |
|
Torque accuracy |
±5% |
±5% |
|
Torque response time |
<20ms |
<10ms |
|
Product features |
Key functions |
Undervoltage regulation, three ground switching, speed tracking, torque limitation, multi-stage operation (up to)23Paragraph), self-tuningSAcceleration and deceleration of segmented curvesturnDifferential compensation, droop control, current limiting control, torque/Speed control mode switching, manual/Automatic torque boost, current limiting, multifunctional input terminal/output terminal |
|
*Frequency setting method |
Operation panel settings, terminalsUP/DNSettings, upper computer communication settings, simulation settingsAI1/AI2/AI3Terminal pulse setting |
||
frequency range |
0.00~300.00Hz noteUnder open-loop vector control operation mode0.0~3200.0HzCan be customized according to customer needs |
||
Starting frequency |
0.00~60.00Hz |
||
Acceleration |
0.1~36000s |
||
|
Energy consumption braking ability |
Braking unit operating voltage:650~750V;V5/V6−MA−4T30GWithin and below the braking unitplace |
||
|
DC braking ability |
DC braking starting frequency:0.00~300.00HzDC braking current: constant torque 0.0~120%Variable torque0. 0~90% DC braking time:0.0~30.0sNo need for DC braking start waiting time, achieving fast braking |
||
|
Magnetic flux braking function |
Continuous action or no action during deceleration are optional, and the factory defaults to no action during deceleration |
||
Featured Features |
multi-functionalMkey |
The unique multifunctional keys can be used to set frequently used operations:JOGEmergency parking, switching of operation command modes, menu switching, etc |
|
Multi menu mode |
Basic menu mode, quick menu mode, non factory value function code menu mode |
||
Parameter copying |
The standard operation panel can realize parameter uploading and downloading, and has a copy progress indicator; You can choose to prohibit uploading and overwriting parameters that have already been uploaded |
||
|
Function code display implicit |
Customers can customize the display and hiding of any function code group |
||
|
*double485 communication port |
double485Communication interface supportModbusAgreement(RTU)The standard operation panel can achieve remote control box function, the farthest500rice |
||
control panel |
Optional button type or shuttle type operation panel, with a protection level standard ofIP20Protection levelIP54optional |
||
Common DC bus |
The entire series can achieve multiple drivers sharing DC bus power supply |
||
Independent air duct |
The entire series adopts an independent air duct design and supports installation outside the radiator cabinet |
||
|
Universal Expansion interface |
Support customers in secondary developmentCPUUniversal Expansion Board: Physical InterfaceSPIBus, software protocolModbus |
||
Power-On Self-Test |
Implement power on self-test for internal and peripheral circuits, such as motor grounding+10VAbnormal power output, abnormal analog input, disconnection, etc |
||
protection function |
Power undervoltage, overcurrent protection, overvoltage protection, interference protection, benchmark abnormality, self-tuning fault, module protection, radiator overheating protection, driver overload protection, motor overload protection, peripheral protection, current detection abnormality, output to ground short circuit abnormality, abnormal power outage during operation, input power supply abnormality, output phase loss abnormalityEEPROMAbnormalities, abnormal relay engagement, temperature sampling disconnection, encoder disconnection+10VAbnormal power output, abnormal analog input, motor overheating(PTC)Communication abnormality, version compatibility abnormality, copy abnormality, expansion card connection abnormality, terminal mutex check failed, hardware overload protection |
||
efficiency |
At rated power,7.5kWPower level and below≥93%;30kWPower level and below≥95% |
||
environment |
Usage location |
Vertically installed in a well ventilated electrical control cabinet. Horizontal or other installation methods are not allowed. The cooling medium is air. Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, oil mist, steam, and dripping water |
|
ambient temperature |
-10~+40℃,40~50℃Reduce usage between levels, with each increase1℃The rated output current decreases1% |
||
humidity |
5~95%Condensation is not allowed |
||
altitude |
0~2000Mi,1000Reduce the usage of meters and above, with each increase100Meter, reduced rated output current1% |
||
vibration |
3.5 m/s2,2~9Hz;10 m/s2,9~200Hz;15 m/s2,200~500Hz |
||
Storage temperature |
-40~+70℃ |
||
*V5−MAnoneAI3Terminal and pulse input, pulse output.
* V5−MAOnly provide one keyboard485Communication interface, none485Terminal;

The appearance, installation dimensions, and approximate weight of the product
|
electricitypress level |
Inverter model |
Appearance and installation dimensions(mm) |
approximately weight (kg) |
|||||||
W |
H |
D |
W1 |
H1 |
D1 |
T1 |
mounting holed |
|||
200V |
V5/V6−MA−2T0.4G |
118 |
190 |
155 |
105 |
173 |
40.8 |
3 |
5.5 |
1.5 |
V5/V6−MA−2T0.75G |
175 |
60.5 |
4 |
2.2 |
||||||
V5/V6−MA−2T1.5G |
155 |
40.8 |
3 |
1.5 |
||||||
V5/V6−MA−2T2.2G |
175 |
60.5 |
4 |
2.2 |
||||||
400V |
V5/V6−MA−4T0.75G |
118 |
190 |
155 |
105 |
173 |
40.8 |
3 |
5.5 |
1.5 |
V5/V6−MA−4T1.5G |
118 |
190 |
175 |
105 |
173 |
60.5 |
4 |
5.5 |
2.6 |
|
V5/V6−MA−4T2.2G | ||||||||||
V5/V6−MA−4T3.7G | ||||||||||
V5/V6−MA−4T5.5G |
155 |
249 |
185 |
136 |
232 |
69 |
8 |
5.5 |
3 |
|
V5/V6−MA−4T7.5G | ||||||||||
V5/V6−MA−4T11G |
210 |
337 |
200 |
150 |
324 |
107.5 |
2.5 |
7 |
8.5 |
|
V5/V6−MA−4T15G | ||||||||||
V5/V6−MA−4T18.5G |
285 |
440 |
220 |
200 |
425 |
107.5 |
2.5 |
7 |
17 |
|
V5/V6−MA−4T22G | ||||||||||
V5/V6−MA−4T30G | ||||||||||
V5/V6−MA−4T37G |
315 |
575 |
227 |
220 |
553 |
123.5 |
2.5 |
10 |
25 |
|
V5/V6−MA−4T45G | ||||||||||