V5/V6-MA machine tool spindle dedicated driver

NegotiableUpdate on 12/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

V5/V6 − MA − 4T □□□ G three-phase 400V constant torque/heavy-duty application power (kW) 0

Product Details

V5/V6-MA机床主轴专用驱动器

V5/V6−MA−4T □□□G three-phase400Vconstant torque/Heavy-duty use

Power(kW

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

Adapted motor

Power(kW

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

lose
go out

Voltage(V

3phase0Rated input voltage

rated

Current(A

2.5

3.8

5.5

9

13

17

24

30

39

45

60

75

91

overload

ability

150% 1minute,180% 10In seconds,200% 0.5Seconds, intervals 10Minutes (inverse time characteristic)

lose
enter

rated

voltage/frequency

3phase380V480V50Hz/60Hz

allow

voltagescope

323V528VVoltage imbalance:≤3%Allow frequency fluctuations:±5%

rated

Current(A

2.8

4.2

6.1

10

15

19

26

33

43

50

66

83

100

brake unit

Standard built-in

Protection level

IP20

cooling method

Self cooling

forced air cooling

















V5/V6−MA−2T □□□G single/three-phase200Vconstant torque/Heavy-duty use

Power(kW

0.4

0.75

1.5

2.2

Adapt motor power(kW

0.4

0.75

1.5

2.2

lose
go out

Voltage(V

3phase0Rated input voltage

Rated current(A

3

5

7.5

10

overload capacity

150% 1minute,180% 10In seconds,200% 0.5Seconds, intervals 10Minutes (inverse time characteristic)

lose
enter

rated

voltage/frequency

3Phase or single-phase200V240V50Hz/60Hz

allow

voltage range

180V260VVoltage imbalance:≤3%Allow frequency fluctuations:±5%

Rated current(A

3.8

5.5

8.3

12

brake unit

Standard built-in

Protection level

IP20

cooling method

Self cooling

forced air cooling


control

manufacture

special

sex

Control method

Open loop vector control (without encoder)

Closed loop vector control (with encoder)

starting torque

0.25Hz 180%

0.00Hz 180%

speed regulation range

1:200

1:1000

Steady speed accuracy

± 0.2%

± 0.02%

torque control

have

have

Torque accuracy

±5%

±5%

Torque response time

<20ms

<10ms

Product features

Key functions

Undervoltage regulation, three ground switching, speed tracking, torque limitation, multi-stage operation (up to)23Paragraph), self-tuningSAcceleration and deceleration of segmented curvesturnDifferential compensation, droop control, current limiting control, torque/Speed control mode switching, manual/Automatic torque boost, current limiting, multifunctional input terminal/output terminal

*Frequency setting method

Operation panel settings, terminalsUP/DNSettings, upper computer communication settings, simulation settingsAI1/AI2/AI3Terminal pulse setting

frequency range

0.00300.00Hz noteUnder open-loop vector control operation mode0.03200.0HzCan be customized according to customer needs

Starting frequency

0.0060.00Hz

Acceleration

0.136000s

Energy consumption braking

ability

Braking unit operating voltage:650750VV5/V6−MA−4T30GWithin and below the braking unitplace

DC braking

ability

DC braking starting frequency:0.00300.00HzDC braking current: constant torque 0.0120%Variable torque0. 090%

DC braking time:0.030.0sNo need for DC braking start waiting time, achieving fast braking

Magnetic flux braking

function

Continuous action or no action during deceleration are optional, and the factory defaults to no action during deceleration

Featured Features

multi-functionalMkey

The unique multifunctional keys can be used to set frequently used operations:JOGEmergency parking, switching of operation command modes, menu switching, etc

Multi menu mode

Basic menu mode, quick menu mode, non factory value function code menu mode

Parameter copying

The standard operation panel can realize parameter uploading and downloading, and has a copy progress indicator; You can choose to prohibit uploading and overwriting parameters that have already been uploaded

Function code display

implicit

Customers can customize the display and hiding of any function code group

*double485

communication port

double485Communication interface supportModbusAgreement(RTU)The standard operation panel can achieve remote control box function, the farthest500rice

control panel

Optional button type or shuttle type operation panel, with a protection level standard ofIP20Protection levelIP54optional

Common DC bus

The entire series can achieve multiple drivers sharing DC bus power supply

Independent air duct

The entire series adopts an independent air duct design and supports installation outside the radiator cabinet

Universal Expansion

interface

Support customers in secondary developmentCPUUniversal Expansion Board: Physical InterfaceSPIBus, software protocolModbus

Power-On Self-Test

Implement power on self-test for internal and peripheral circuits, such as motor grounding+10VAbnormal power output, abnormal analog input, disconnection, etc

protection function

Power undervoltage, overcurrent protection, overvoltage protection, interference protection, benchmark abnormality, self-tuning fault, module protection, radiator overheating protection, driver overload protection, motor overload protection, peripheral protection, current detection abnormality, output to ground short circuit abnormality, abnormal power outage during operation, input power supply abnormality, output phase loss abnormalityEEPROMAbnormalities, abnormal relay engagement, temperature sampling disconnection, encoder disconnection+10VAbnormal power output, abnormal analog input, motor overheating(PTC)Communication abnormality, version compatibility abnormality, copy abnormality, expansion card connection abnormality, terminal mutex check failed, hardware overload protection

efficiency

At rated power,7.5kWPower level and below≥93%30kWPower level and below≥95%

environment

Usage location

Vertically installed in a well ventilated electrical control cabinet. Horizontal or other installation methods are not allowed. The cooling medium is air. Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, oil mist, steam, and dripping water

ambient temperature

-10+40℃4050℃Reduce usage between levels, with each increase1℃The rated output current decreases1%

humidity

595%Condensation is not allowed

altitude

02000Mi,1000Reduce the usage of meters and above, with each increase100Meter, reduced rated output current1%

vibration

3.5 m/s229Hz10 m/s29200Hz15 m/s2200500Hz

Storage temperature

-40+70℃

*V5−MAnoneAI3Terminal and pulse input, pulse output.

* V5−MAOnly provide one keyboard485Communication interface, none485Terminal;

V5/V6-MA机床主轴专用驱动器

V5/V6-MA机床主轴专用驱动器

The appearance, installation dimensions, and approximate weight of the product

electricitypress

level

Inverter model

Appearance and installation dimensions(mm

approximately

weight

kg

W

H

D

W1

H1

D1

T1

mounting holed

200V

V5/V6−MA−2T0.4G

118

190

155

105

173

40.8

3

5.5

1.5

V5/V6−MA−2T0.75G

175

60.5

4

2.2

V5/V6−MA−2T1.5G

155

40.8

3

1.5

V5/V6−MA−2T2.2G

175

60.5

4

2.2

400V

V5/V6−MA−4T0.75G

118

190

155

105

173

40.8

3

5.5

1.5

V5/V6−MA−4T1.5G

118

190

175

105

173

60.5

4

5.5

2.6

V5/V6−MA−4T2.2G

V5/V6−MA−4T3.7G

V5/V6−MA−4T5.5G

155

249

185

136

232

69

8

5.5

3

V5/V6−MA−4T7.5G

V5/V6−MA−4T11G

210

337

200

150

324

107.5

2.5

7

8.5

V5/V6−MA−4T15G

V5/V6−MA−4T18.5G

285

440

220

200

425

107.5

2.5

7

17

V5/V6−MA−4T22G

V5/V6−MA−4T30G

V5/V6−MA−4T37G

315

575

227

220

553

123.5

2.5

10

25

V5/V6−MA−4T45G