The urine fluoride analysis instrument adopts a large screen Chinese LCD display, touch operation mode, human-machine dialogue, functions *, and extremely convenient operation and maintenance. Adopting advanced USB interface communication method. Conveniently share the corresponding test result data of the instrument to the computer. Query, edit, and record any print output. The instrument adopts an ARM architecture fast and high-performance processor to ensure efficient and accurate test results.
Characteristics of urinary fluoride analysis instrument:
1. Adopting a large Chinese LCD display screen, touch control operation mode, human-machine dialogue, functions *, extremely convenient operation and maintenance.
2. Adopt advanced USB interface communication method. Conveniently share the corresponding test result data of the instrument to the computer. Query, edit, and record any print output.
3. The instrument adopts an ARM architecture fast and high-performance processor to ensure efficient and accurate test results.
4. The instrument has a power-off protection function, and shutting down will not cause the loss of stored measurement data, calibration results, and other parameters.
5. There are multiple modes for concentration measurement, including direct reading concentration, standard addition, sample addition, GRAN measurement, etc.
6. The instrument supports multiple conventional ion modes, such as K+, Na+, Cl -, Ca2+, WH, pH, F -, NO3-, etc.
7. Quickly switch between various ion concentration units, such as mg/L, g/L, mmol/L, mol/L, pX, etc.
8. The instrument comes with a thermal printer, which can print out the test results in a timely manner during measurement.

Parameters of urinary fluoride analyzer:
1. Instrument level: 0.001 level;
2. Measurement range: pH: 0.000pH to 14.000pH; pX:1.000pX~8.000pX; mV:-1999.9mV~1999.9mV; Ionic concentration: Sodium ions (0.23 μ g/L~2.3g/L); Fluoride ions (0.19 μ g/L~1.9g/L), etc., temperature: (0-60.0) ℃.
3. Resolution: pH/pX: 0.001pH/pX; mV:0.1mV; Small resolution: 0.01 μ g/L Temperature: 0.1 ℃.
4. Basic error of electronic unit: pH/pX: ± 0.002pH/pX; MV: ± 0.03% FS; ion concentration: ± 0.3%; Temperature: ± 0.1 ℃.
5. Repeatability of electronic units: a) pH/pX: 0.001pH/pX; b) mV:0.1mV;
6. Stability of electronic unit pH/pX: (± 0.01pH/pX)/3h
7. Basic error of the instrument pH/pX: ± 0.01pH/pX Temperature: ± 0.4 ℃ (0-60.0) ℃
8. Input impedance: greater than 1 × 1012 Ω.
9. Temperature compensation: (0.1-60.0) ℃ (manual or automatic)
10. Water sample temperature: (5-60) ℃
11. Storage and transportation temperature: (-25~55) ℃ (excluding electrodes, electrodes should be above 0 ℃)
12. Power supply: AC (198-242) V, frequency 50Hz ± 1Hz
13. Dimensions (mm): 342 × 255 × 129
14. Instrument weight: 2kg