UL series ironless linear motor

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

UL series ironless linear motor

Product Details

High end UL ironless motors have multiple configurations available, making it easy to meet specific application needs. Because the UL series has high speed, high positioning accuracy, zero cogging effect, and zero attraction, many UL motors can be successfully applied throughout the semiconductor industry.

Specifications

parameter symbol unit UL3 UL6 UL9 UL12 UL15
winding type N S N S N S N S N S
Motor type, maximum phase to phase voltage 3-phase synchronous ironless, 230Vac rms (300Vdc)
Peak thrust (at a temperature rise of 20 ℃/s) Fp N 240 480 720 960 1200
Continuous thrust* Fc N 70 140 210 280 350
Maximum speed** vmax m/s 5 12 5 12 5 12 5 12 5 12
Motor thrust constant K N/Arms 68 27.5 68 27.5 68 27.5 68 27.5 67.5 27.5
motor constant S N2/W 97 195 290 390 485
peak current Ip Arms 3.5 8.7 7 17.5 10.5 26.2 14.1 35 17.8 44
Maximum continuous current Ic Arms 1.03 2.6 2.1 5.1 3.1 7.6 4.2 10.2 5.2 12.9
Phase peak reverse electromotive force Bemf V/m/s 55.5 22.5 55.5 22.5 55.5 22.5 55.5 22.5 55.5 22.5
Resistance/Phase* Rph 15.9 2.6 8 1.28 5.3 0.85 4 0.64 3.3 0.53
Inductance/Phase Lph mH 13 2 6.5 1 4.2 0.7 3.2 0.5 3 0.4
Electrical time constant* τe ms 0.8 0.8 0.8 0.8 0.8
Maximum continuous power consumption Pc W 67 134 200 270 335
thermal resistance Rth °C/W 1.3 0.65 0.43 0.32 0.26
Thermal time constant* τth s 72 72 72 72 72
temperature sensor PTC 1kΩ / NTC
Weight of the moving object W kg 0.25 0.47 0.69 0.91 1.13
Length of mover L mm 106 190 274 358 442
Motor attraction Fa N 0 0 0 0 0
Magnetic pole distance NN τ mm 42 42 42 42 42
Cable quality m kg/m 0.09 0.09 0.09 0.105 0.105
Type of power cable d mm (AWG) 5.8 (20) 6.4 (18)
Temperature sensor cable type d mm (AWG) 4.3 (26) 4.3 (26)

*These values are only applicable when the installation surface is at 20 ° C and the motor is driven at maximum continuous current. If these values are different in your application, please check our selection software.
**The actual value depends on the bus voltage. Please check the F/V chart in the selection software.

Stator size
Length (mm) 126 168 210 546
M5 bolt 3 4 5 13
Mass (kg/m) 11.2