Two slot high and low temperature impact test chamber

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The two slot high and low temperature impact test chamber is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. At the same time, through this equipment test, product reliability can be improved and product quality control can be carried out. The high and low temperature impact test chamber is a testing equipment used in fields such as aviation, automotive, home appliances, and scientific research. All functions of the mechanical sheet metal structure are controlled by computers and are independently developed software with a user-friendly interface, making user operation and monitoring simpler and more intuitive. Maintaining functionality can keep the running program in its current state.

Product Details

Two door thermal shock box/Two slot high and low temperature impact test chamberThis product is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. Through this equipment test, the reliability of the product can be improved and quality control can be carried out. The high and low temperature impact test chamber is a testing equipment used in fields such as aviation, automotive, home appliances, and scientific research.

All functions of the mechanical sheet metal structure are controlled by a computer, which is a self-developed software with a good operating interface, making user operation and monitoring simpler and more intuitive. The hold function can keep the running program in its current state, temporarily change the values of this program segment, set the time and parameters on the screen, and automatically switch between cooling, heating, and blue transfer according to the set values.

Temperature shock test chamber

[1] The cold box and hot box are independently controlled, and the box doors are independent of each other, expanding the scope of use of the test box (one box for three purposes). The insulation effect of the product can be fully guaranteed.

The door of the test chamber is interlocked with the circulating fan, lifting and blue drive, etc., to protect the safety of the operator. Once the door is opened, the power supply of the circulating fan and lifting and blue drive will be automatically cut off. There are standard lead hole tubes on the top of the box, which facilitate users to introduce sensor wires, detect cables and other types of leads into the box.

control system

The transition time between low-temperature and high-temperature zones is less than or equal to 15 seconds.

The temperature recovery time is less than or equal to 5 minutes.

meet the standard

GB/T2423.1.2-2001GJB150.5GB10592-89

parameter list

Selection

Model (mm)

CC-WDCJ-100

JW-WDCJ-300

CC-WDCJ-500

CC-WDCJ-010

Two boxes of pre cooling area dimensions D × W × H

450×450×500

600×600×600

800×800×800

1 000×1000×1000

Three boxes of sample area dimensions D × W × H

450×450×500

600×600×600

800×800×800

1000×1000×1000

Temperature operation control system

controller

Imported LED digital display (P, I, D+S, S, R.) microcomputer integrated controller

heating system

Fully independent system, nickel chromium alloy electric heating heater

refrigeration system

Fully enclosed air-cooled single-stage compression refrigeration method/Original French "Taikang"/Fully enclosed air-cooled cascade compression refrigeration method

circulatory system

Temperature resistant and low-noise air conditioning motor Multi blade centrifugal wind turbine

Standard Configuration

One set of multi-layer heating defrost with illuminated glass windows, two sample racks, and one test lead hole (25, 50mm).

safety protection

Leakage, short circuit, overheating, motor overheating, compressor overpressure, overload, overcurrent protection.

Temperature conversion time

From low temperature zone to high temperature zone or from high temperature zone to low temperature zone ≤ 15S.

Temperature response time

≤ 5 minutes (related to temperature recovery conditions, including cooling water temperature, exposure temperature difference, constant temperature time, and sample weight).

Temperature shock method

Vertical two box method/Vertical three box method.

Two slot cold and hot shock test box JW-WDCS-100 Two box cold and hot shock test box&Two slot high and low temperature impact test chamberThis product is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. Through this equipment test, the reliability of the product can be improved and quality control can be carried out. The high and low temperature impact test chamber is a testing equipment used in fields such as aviation, automotive, home appliances, and scientific research.