Welcome Customer !

Membership

Help

Chuangcen Instrument Equipment (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Chuangcen Instrument Equipment (Shanghai) Co., Ltd

  • E-mail

  • Phone

  • Address

    Building 3, No. 518 Zhongda Road, Jinshan District, Shanghai

Contact Now

Sichuan Rubber Mooney Viscometer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Sichuan Rubber Mooney Viscometer $r $n1. Temperature measurement range 0-200 ℃ $r $n2. Temperature resolution 0.1 ℃ $r $n3. Torque range 0-100 Mooney value $r $n4. Environmental temperature 0-35 ℃ $r $n5. Gas distribution 0.45-0.6MPA $r $n6. Machine weight: about 210Kg

Product Details

Sichuan Rubber Mooney ViscometerMain counting indicators:

A. Temperature measurement range 0-200 ℃ B. Temperature measurement accuracy ≤± 0.3 ℃

C. Control accuracy ≤± 0.3 ℃ D. Temperature resolution 0.1 ℃

E. Torque range 0100 Mooney value F. Calibration accuracy 100 ± 0.5 Mooney value

G. Rotor speed 2 ± 0.02 revolutions per minute H. Measurement time 0200, resolution 1 second

I. Environmental temperature 0-35 ℃ J. Relative humidity<80%

K. Test pressure 11.5KN ± 0.5KNL. Gas distribution 0.450.6MPA

M. Power supply AC 220V 1KVAN. Machine size: approximately 660 × 570 × 1300mm

O. Machine weight: approximately 210Kg

A. High precision sensor: 0-100 Mooney values. The accuracy of the Mooney value is within ± 0.5 Mooney values. Resolution: 1/10 Mooney value

B. Control system: Computer control and interface board are used for data acquisition, storage, processing, and printing of test results and curve processing.

C. Rotating system: using gear reduction Electronics speed control motor+gear reduction gearbox+reduction gear. Rotor speed: 2 ± 0.02r/min.

D. Temperature control system: Using Inigent digital temperature control instruments, real-time automation adjusts PID control parameters. The temperature control range is 0-200 ℃, the temperature measurement control accuracy is ≤± 0.3 ℃, and the temperature resolution is 0.1 ℃.

E. Data transmission method: RS232 transmission

F. Display mode: Viscosis-106+WIN-XP test software computer screen display, combined with excellent user software and * hardware

The equipment makes the entire measurement very convenient, fast, accurate, and enjoyable.

G. Rotor: Made of Cr6wv material, the large rotor has 24 flat teeth with a diameter of 38.10 ± 0.03, and the small rotor has 19 flat teeth with a diameter of 30.48 ± 0.03.

F. Measurement and control method: Humanized measurement and control method, with two testing methods: mouse click and play or touch button on the host panel

Sichuan Rubber Mooney ViscometerSoftware Function Introduction:

A. Standardization of Testing: Compliant with GB/T1232 "Determination of Mooney Viscosity of Unvulcanized Rubber", GB/T1233 "Determination of Initial Vulcanization Characteristics of Rubber Compounds by Mooney Viscometer Method", and ISO289, ISO667 and other standards.

B. Sample data: Set the rubber material number name, such as "Outer Tire No. 5", "RBS6", etc. If the user needs to add a title name, please provide an explanation

When printing drawings, any form of title text description can be set.

C. Special note on high-quality features: The excellent feature of humanized design is that the measurement time can be modified during the testing process. The rubber material is estimated to have a measurement time of 20 minutes. When tested for 11 minutes, it was found that the measurement was 9 minutes, and at 10 minutes, it was already t18. If it is a small rotor, the measurement has been completed. T35 measurement, if it is a large rotor, the measurement is also completed. At this point, there is no need to continue. Press' send as', and the experiment will immediately stop at 9 or 10 minutes. Draw the complete Mooney curve, calculate all data, and store the data curve in the database. If T18 or T35 is not measured within 20 minutes, the experiment will automatically move down the measurement time (manual modification of measurement time is also acceptable) until T18 or T35 is measured. If no measurement is taken at t18 or t35 within 200 minutes, the measurement will automatically end. This feature undoubtedly greatly facilitates users, saving valuable time and adhesive materials.

D. AutoScale is used to automatically adjust the Y scale of the graph curve. After the measurement is completed, the software will adjust the Y scale according to the measurement value between 0100Mv0-200Mv to make the curve more beautiful. Multiple curve comparisons can also be made for different rubber materials, curve shapes, and measurement times.

E. Database: The software has pre-set a database with 100 numbers. Each library can store unlimited sets of measurement data. Faced with thousands of sets of data for months, years, decades, and convenient future queries, users can put data from different time periods into different databases, and the purpose of setting database addresses is for this.

F. After the test is completed, it will be automatically archived, and after the test is completed, it will automatically calculate the Zui Da Men Ni and Zui Xiao Men Ni tH、tL、Mend、Tend、 △ 15, △ 30, M (1+4), M (1+5), M (1+6), M (1+7), M (1+8), M (1+F), and so on.