Welcome Customer !

Membership

Help

Shenzhen Tongrui Chromatography Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shenzhen Tongrui Chromatography Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    http://www.gi3000xy.com/

Contact Now

Two dimensional liquid chromatography

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The TR-1000 two-dimensional liquid chromatography system is based on a quaternary low-pressure gradient liquid chromatography system and is a fully intelligent quaternary low-pressure gradient liquid chromatography system with online solid automatic phase extraction.

Product Details


TR-1000 Two dimensional liquid chromatography/Blood drug concentration detector



1. ProductsPurpose:

Used clinically to analyze organic compounds derived from human blood samplesAnd inorganic ionic substancesQualitative and quantitative testing.Detectable drugs:Psychiatric drugsAntiepileptic drugs, hypnotic sedatives, anti-tumor drugs, antibiotics, anti tuberculosis drugs, monoamine drugs, analgesic drugs, circulatory system drugs, gastrointestinal drugs, and other inorganic ion drugs, etc


2、 Functions of each unit andtechnologyparameter

1Four element low-pressure gradientConstant flow pump:


Technical Specifications Table




2UV detector:

1 have5inchtouch controldisplaycolor screenFunction,And it has computer software anti control function

2 The detector adopts dual channel data and high precision24bitADConversion and signal sampling frequency up to80hz/sHigh speed data collector ensures high-speed, low-noise, low drift, and ultra-high sensitivity detection of the detector.

3 Adopting a new typeHType flow pool, bidirectional convection, ensuring minimal fluctuations in the baseline

Technical Specifications Table

Wavelength range:

190nm~700nm

Wavelength indication error:

≤±1nm

Wavelength repeatability error:

≤±1nm

Dynamic noise:

0.75×10-5AU(Methanol,1mL/min,254nm,20℃

Static noise:

≤±0.5×10-5AU(Empty pool, response time)1In seconds,20℃

Dynamic baseline drift:

1×10-4AU/h(Methanol,1mL/min,254nm,20℃

Static baseline drift:

≤0.5×10-4AU/h(Empty pool, response time)1In seconds,20℃

Linear range:

104

Detection concentration:

2×10-9g/mL(Naphthalene)/Methanol solution

Qualitative repeatability:

RSD6≤0.1%

Quantitative repeatability:

RSD6 ≤0.5%

Spectral bandwidth:

5nm

Flow pool volume:

8μL

optical path

8mm

Wavelength scanning:

Multi wavelength time programming(10Band)

Time program function:

have



3. Automatic sampler

1 Automatic sampler requires high-pressure injection and mobile phase needle passing technology, without the need to clean the inner wall of the injection needle. The outer wall is automatically cleaned to reduce sample residue.

2 Sample injection adopts quantitative loop method and automatic injection.

3 Before injection, the outer wall of the injection needle can be automatically cleaned to reduce cross contamination of the sample

4systemhaveOnline automatic enrichment completionfunction.

Technical Specifications Table

Repeatability:

RSD6 ≤0.5%,Full quantitative loop, partial injection

Minimum residue:

≤0.005%

Linearity:

0.999

Injection accuracy:

1%

Sample quantity:

144a 2mlsample

Minimum injection volume:

0.1ul

Rapid injection:

10ulDuring injection20s

Injection volume:

1000µl (typical value500µl)

Injection valve switch speed:

<100mSec

Position control accuracy:

<0.3mm

Power Supply:

220v±10%50hz 150w



4. Column temperature box

1 Column temperature boxThe parameters can be set and controlled by the chromatographic data processing workstationEquipped with computer software anti control function

Technical Specifications Table

Temperature control range:

5℃~80 ℃ (room temperature<25 ℃)

Temperature control accuracy:

≤±0.1℃

Temperature can be controlled in both directions:

Refrigeration and Heating

Temperature setting resolution:

0.1℃



5High pressure dilution pump:

5.1 Computer control with online automatic dilution functionNo matter the injection volume, there is no need for nitrogen blowing operation, fully automatic processing, eliminating the trouble of manual intervention.

Technical Specifications Table

flow range

0.001-9.999ml/minSet step size:0.001mL/min

Traffic accuracy:

<±1%

Maximum pump pressure:

45Mpa

6Chromatography workstation:

1 The software meets the requirementsGMPRequired user permission management, audit tracking function

2 The software comes withMySQLThe database management function stores all key data in the database and has the ability to import and export data.

3 It has a sample table batch processing function, which means that after the sample table is established, all sample tests can be completed with one click. After the sample is completed, automatic column flushing and intelligent shutdown can be set to achieve unmanned operation.

4 The main interface can complete most operations without switching back and forth between multiple interfaces. Data analysis is based on actual collected data to ensure its authenticity. The workstation has the ability to compare spectra in multiple forms, which is beneficial for chromatographic research;

5 softwareJAVALanguage writing, software with high scalability, and cross platform functionality.canPerform full reverse control operation control, automatic data acquisition, spectrum processing, etc. on the system. One software for data setting, collection, analysis, and viewing, easy to operate.

6 Full Chinese operation menu,Intuitive and convenient user-friendly interface; Implement data collection, calculation, organization, storage, and printing on the front and rear consolesAnalyze the parameters, spectral data, and analysis report of the chromatographcanLong term storage and unified management;


Product Usage

  1. Used in clinical practice for qualitative and quantitative detection of organic compounds derived from human blood samples.

  2. Scope of detectable drugs: psychiatric drugs, antiepileptic drugs, anti-tumor drugs, sedative hypnotic drugs, analgesic drugs, antibiotics, anti tuberculosis drugs, monoamine drugs, gastrointestinal drugscirculatory systemOr other drugs, etc.



Two dimensional liquid chromatography