The ion chromatograph (automatic injection system) is a universal instrument in Shenzhen, GI-1100A automatic injection ion chromatograph. The system consists of main components such as an automatic sampler, a constant current pump, a conductivity detector, a column temperature box, a suppressor, and a separation column. The instrument has good overall integrity, simple operation, and easy maintenance. It can be applied to routine anion or cation analysis, routine anion detection \\ routine cation detection

Product Details

Ion chromatograph (automatic injection system) Shenzhen General Instrument


GI-1100AIon Chromatograph

Model:GI-1100A (Automatic Sample Injection System

离子色谱仪(自动进样系统)深圳通用仪器


1、 Introduction:

GI-1100AAutomatic samplingIon chromatograph, system composed ofautosamplerThe instrument is composed of main components such as a constant current pump, conductivity detector, column temperature box, suppressor, and separation column. It has good overall integrity, simple operation, and easy maintenance.

It can be applied to conventional yinIons orCation analysisregularaniondetection F-TheCl-TheNO2-ThePO43-TheBr-TheSO42-TheNO3-TheClO2-TheBrO3-TheClO3- wait Conventional Yangiontesting:Li+TheNH4+TheNa+TheK+TheMg2+TheCa2+wait

The system can be optionally equipped with a shower solution generator to enhance the performance of the instrument.

The entire system is controlled and processed by a set of software, which greatly facilitates user operation.

IIAdvantages and characteristics of the product:

1. The system has automatic sampling function

2Adopting the original factory production standard for the entire systemPEEK material flow path. Including the analysis pump itself and all pipelines between the analysis pump and the six way valve, chromatographic column, suppressor, and detector, effectively preventing acid-base corrosion.

3The entire system is controlled and processed by a set of software, which greatly facilitates user operation

4High pressure constant current pump: high performance, low pulsePeek dual plunger constant current pump adopts a high-precision stepper motor driven precision ball screw system to improve system performance, reliability, stability, and durability.

5Intelligent bipolar conductivity detector, range:0.0001~16000μS, No need to shift gears, automatic range adjustment, sampling frequency up to 100Hz, ensuring the authenticity of the detection spectrum description and the accuracy of the detection results.

6The detection unit module adopts an independent temperature control mode between the chromatographic column and the detection module, effectively preventing the retention time of chromatographic peaks and column pressure fluctuations that may be caused by temperature changes.

7UV detector can be selected and connected behind the conductivity detector to achieve dual detection.

8Can be connected to an electrolytic washing solution generation device to achieve chemical free ion chromatography function. Regarding the occurrence of low concentration of washing solution(0.1-10mmol), Adopt special measures to improve the accuracy and reproducibility of concentration occurrence.

9adoptUSBThe high-speed data transmission connection interface can be connected to other devices and automatically recognize computers or other optional componentsThis ensures that the instrument has reliable performance and excellent quality.

10The chromatographic data processing system software adopts internationally mainstream structural design patterns and functional modules, with simple and convenient operation.

11Can be connected to nitrogen gas cylinders or nitrogen generators, using imported pressure regulating valves(0-0.2Mpa)AndPPRinse solution bottle, system pressure resistant and nitrogen filled to protect against air leakage, non-metallic solvent filtration system.

12System optionalincreaseRinse solution generator to enhance the performance of the instrument.

13After replacing the cation chromatography column, suppressor, and eluent bottle, and thoroughly cleaning the system pipeline components, cation detection can be performed.

3、 Main technical parameters and functions of the product

1. Overall performance indicators:

(1) Detection limit: ≤ 1pppb (calculated as Cl -)

(2) Baseline drift: ≤± 1%/hour

(3) Reproducibility: better than 2% (calculated as SO42-)

(4) Linear range: greater than 102

2autosampler

(1)Injection position:64 bit (8 * 8, 10m)L)Or144Position(12*12,2mL

(2)Control mode: stepper motor

(3)Injection volume: full ring

(4)Syringe:250,500,1000,5000uLChoose one

3Peek dual plunger constant flow pumpunit

(1) Maximum pressure resistance: 35MPa

(2) Pressure display accuracy: ≤ 0.1MPa

(3) Flow range: 0.01-99.99mL/min

(4) Pressure pulsation: ≤ 1% MPa

(5) Traffic stability: ≤0.3%

4. Column temperature box unit

(1) Temperature control range: room temperature -60 ℃

(2) Temperature control accuracy: ± 0.01 ℃

(3) Temperature stability: ≤ 1 ℃/h

5Temperature controlled bipolar conductivity detectorunit

(1)Range:0.0001-16000MSNo need to shift gears,

(2)Detection frequency up to100Hz

(3)Maximum withstand voltage:10Mpa1500psi

(4)Instrument linearity:0.999

(5)Qualitative repeatability:1%

(6)Quantitative repeatability:1%

(7)Constant temperature accuracy: room temperature~60±0.01


6. Rinse solution generator (optional)





No need for manual configuration, through pure





Water can generate washing solution online; Equivalently eluted, with high consistency in the concentration of the eluent; Gradient elution is used to analyze complex samples that cannot be completed by isocratic elution.

(1)Type of rinsing solution:KOH/MSA

(2)Rinse solution concentration:0.1-100mM

(3)Concentration increment:0.1mM

(4)Flow rate range:0.1-3.0mL/min

7Tyrannosaurus rex chromatography workstation

Tyrannosaurus rex The 1.0 chromatography workstation is customized and developed by a professional software company, and is a large-scale chromatography software work platform developed according to the structure, functions, modes, and operation methods of today's international mainstream chromatography software. Its functions are very powerful.

Unlike most domestic ion chromatography manufacturers who use multiple software simultaneously, the control and data processing of the instrument are integrated into one, and only one software is used to complete all detection functions. The data is saved in database format, which meets certification requirements.

It can display multiple detector windows simultaneously and control multiple chromatographs to run in parallel.

4Configuration List (Anion)detection system

1Automatic sampler 1 unit

2. Host (detailed configuration as follows) 1 unit

1)Conductivity detectorunit 1set

2)Peek dual plunger constant flow pumpunit 1set

3)pillarwarmboxunit 1set

4)Anion chromatography column with protective column 1 set

5)Anion suppressor 1 piece

3Full Chinese chromatographic data workstation 1 set

5scope of application

Can be used in industries such as environmental protection, food, chemical, power, electronics, mining and metallurgy, teaching and research. For conventional anionsCation (optional cation system configuration)Detection of small molecule organic acids, etc



Ion chromatograph (automatic injection system) Shenzhen General Instrument