Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The new three in one thermal conductivity tester, also known as thermal conductivity analyzer or thermal constant analyzer, launched by C-Therm company combines high-precision improved transient plane source with flexible transient plane source and * transient hot wire method.

Product Details


The new three in one thermal conductivity tester Trident, also known as the thermal conductivity analyzer, launched by C-Therm company,Thermal constant analyzerIt combines high-precision Modified Transient Plane Source (MTPS) with flexible Transient Plane Source (FLEXTPS) and Transient Line Source (TLSNEEDLE) techniques.

The MTPS sensing technology of C-Therm makes the testing of thermal conductivity simpler and easier to carry out. There is currently no faster or simpler method on the market to test thermal conductivity, thermal diffusivity, and heat absorption coefficient.

Compared with other transient methods, the C-ThermTrident thermal conductivity tester does not require complex regression analysis, special preparation of samples, or prior knowledge of other material performance parameters such as specific heat capacity.

  

Product features:

1. Wide temperature range: -50 ℃ to 500 ℃.

2. Easy to operate, no need for calibration.

3. High flexibility, suitable for laboratory, quality control, and online testing.

4. No need to prepare samples, sample size is not limited.

5. Wide applicability: It can test solids, liquids, powders, colloids, anisotropic materials, and films, and can be flexibly operated in various environments.

6. Non destructive testing: The sample is not damaged.

Technical parameters:

measurement method

MTPS Flex TPS TLS Needle

Thermal conductivity range

0 ~ 500 W/mK

0 ~ 2000 W/mK

0.1 ~ 6 W/mK

Range of thermal diffusion coefficient

0 ~ 300 mm2/s*

0 ~ 1200 mm2/s

Not applicable

Specific heat range

~ 5 MJ/m3K*

~ 5 MJ/m3K

Not applicable

Range of heat absorption coefficient

5 ~ 40,000 Ws1/2/m2K

Not applicable

Not applicable

Test temperature range

-50 ~ 500°C

-50 ~ 500°C

-55 ~ 300°C

precision

Better than 1%

Better than 2%

Better than 3%

accuracy

Better than 5%

Better than 5%

±(3%+0.02) W/mK

measure time

0.8~3 seconds

10~180 seconds

1~4 minutes

standard

ASTM D7984

ISO 22007-2.2,

GB/T 32064

ASTM D5334, D 5930, IEEE 442