- Phone
-
Address
Floor 1, FM, Building 4, No. 9 Sifang Street, Suzhou Industrial Park
Suzhou Mingdian Electric Co., Ltd
Floor 1, FM, Building 4, No. 9 Sifang Street, Suzhou Industrial Park
test parameters |
C,L,R,Z,Y,X,B,G,D,Q,θ,DCR |
|
test frequency |
TH2826A |
20 Hz~2MHz, 10mHz step |
Test signal level |
f≤1MHz |
10mV~5V,±(10%+10mV) |
f>1MHz |
10mV~1V,±(20%+10mV) |
|
output impedance |
10Ω, 30Ω, 50Ω, 100Ω |
|
Basic accuracy |
0.1% |
|
|
display range
|
L |
0.0001 uH ~ 9.9999kH |
C |
0.0001 pF ~ 9.9999F |
|
R,X,Z,DCR |
0.0001 Ω ~ 99.999 MΩ |
|
Y, B, G |
0.0001 nS ~ 99.999 S |
|
D |
0.0001 ~ 9.9999 |
|
Q |
0.0001 ~ 99999 |
|
θ |
-179.99°~ 179.99° |
|
Measuring speed |
Fast: 200 times/s (f>30kHz), 100 times/s (f>1kHz), medium speed: 25 times/s, slow speed: 5 times/s |
|
Calibration function |
Open/short circuit point frequency, sweep frequency reset, load calibration |
|
Equivalent method |
Series connection method, parallel connection method |
|
Range method |
Automatic, hold |
|
display mode |
Direct reading, Δ, Δ% |
|
trigger method |
Internal, manual, external, bus |
|
Internal DC bias |
Voltage mode |
-5V~+5V, ± (10%+10mV), 1mV step |
Source setting |
Current mode (internal resistance of 50 Ω) |
-100mA~+100mA, ± (10%+0.2mA), 20uA step |
Comparator function |
10 levels of sorting and counting function |
|
monitor |
320 × 240 dot matrix graphic LCD display |
|
存储器 |
Can save 20 sets of instrument settings |
|
|
interface |
USB DEVICE( USBTMC and USBCDC support) |
|
USB HOST(FAT16 and FAT32 support) | ||
LAN(LXI class C support) | ||
RS232C | ||
HANDLER | ||
GPIB (optional) | ||
Test frequency: 20Hz~2MHz, resolution: 10mHz step by step
Basic accuracy: 0.1%
Measurement speed: 200 times/s
Impedance analysis and testing of piezoelectric ceramics, ultrasonic transducers and other devices
Equipped with multi parameter and multi frequency list scanning function
Test voltage level 10mV~5V, 1mV step
320 × 240 dot matrix large graphic LCD display
Five digit reading resolution
Can measure 22 combinations of impedance parameters
Four types of signal source output impedances
10 point list scanning test function
Internally equipped with DC bias source
External bias current source up to 40A (optional)
Automatic Level Adjustment (ALC) function for voltage or current
V. I test signal level monitoring function
Graphic scanning analysis function
20 sets of internal instrument settings available for storage/reading
Built in comparator, 10 level sorting and counting functions
Multiple communication interfaces for convenient online use by users
2m/4m test cable extension (optional)
Chinese and English optional operation interface
The instrument's operating program can be automatically upgraded through USB HOST