Welcome Customer !

Membership

Help

Suzhou Mingdian Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Suzhou Mingdian Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    Floor 1, FM, Building 4, No. 9 Sifang Street, Suzhou Industrial Park

Contact Now

Daily M7100 voltage; Temperature Module

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

High insulation, high-speed sampling and measurement module. Safely conduct charging and discharging tests on high-voltage batteries. $r $n ⊙ Suitable for battery packs ranging from 600 V to 1500 V; $r $n ∝ 15ch, voltage, temperature (thermocouple); $r $n ∝ high-precision measurement of cell voltage; $r $n ∝ High speed data acquisition, with the fastest output of all unit data every 5 ms, supporting HILS (when using UDP output of LR8102).

Product Details

Product Specifications

Compatible Models

Data acquisition instrument LR8101: standard model

Data acquisition instrument LR8102: high-performance model

Temperature and humidity range for use

-10 ℃~55 ℃, below 80% RH (no condensation)

Withstand Voltage

AC 7.4 kV for 1 minute (sensitivity current 1 mA)

Each input channel (+, -) between LR8101 or LR8102 hosts, between modules AC 350 V for 1 minute (sensitivity current 1 mA) between each input channel (+, -)

Number of input channels

15 CH

input terminal

M3 screw terminal board (2 terminals per 1ch) with terminal board protective cover

measurement object

voltage

Thermocouples (K, J, E, T, N, R, S, B, C)

input method

Scanning method based on semiconductor relay and floating unbalanced input

Full channel insulation

A/D resolution

18 bit

Maximum input voltage

DC ±100 V

Maximum voltage between channels

DC 300 V

Maximum rated voltage to ground

DC 1500 V CAT II, expected transient overvoltage of 8000 V

DC 1000 V CAT II, expected transient overvoltage of 6000 V

Maximum rated voltage between modules

DC 1500 V, AC 1000 V

input resistance

Above 100 M Ω (voltage 10 mV f.s~6 V f.s. range, 1-5 V f.s. range, thermocouple full range)

1 M Ω± 5% (voltage range of 10 V f.s to 100 V f.s)

Data update interval

5 ms (*1), 10 ms (*2), 20 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s

*1: All measurement channels in this module are set to voltage range, and can be selected when using channels ranging from 1ch to 8ch

*2: When the thermocouple disconnection detection is set to OFF, it can be selected

Measurement range

电压: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s.

Thermocouples: 100 ℃ F.S., 500 ℃ F.S., 2000 ℃ F.S

Volume and weight

Approximately 53W × 166H × 263D mm, 1.3 kg

Attachment

User manual x 1