E-mail
shjuyigs@163.com
-
Phone
15021203562
-
Address
Tingfeng Road, Zhujing Town, Jinshan District, Shanghai
Shanghai Juyi Environmental Testing Equipment Co., Ltd
shjuyigs@163.com
15021203562
Tingfeng Road, Zhujing Town, Jinshan District, Shanghai
| serial number | model | Studio size (mm) | Appearance (mm) | Power supply/total rate A |
| 01 | JY-JTS-80B | 400×400×500 | 1500×1600×2020 | 380V/18KW |
| 02 | JY-JTS-100B | 400×500×500 | 1500×1700×2020 | 380V/18.5KW |
| 03 | JY-JTS-150B | 500×500×600 | 1600×1700×2100 | 380V/19.5KW |
| 04 | JY-JTS-225B | 750×600×500 | 2000×1800×2100 | 380V/19.5KW |
| 05 | JY-JTS-250B | 700×630×550 | 2000×2000×2100 | 380V/20KW |
| 06 | JY-JTS-512B | 800×800×800 | 2500×2500×2100 | 380V/23W |
| 07 | JY-JTS-1000B | 1000×1000×1000 | 3500×3500×2200 | 380V/25KW |
| 08 | JY-JTS-1500B | 1500×1000×1000 | 4200×3800×3800 | 380V/28KW |
| temperature
| high-temperature chamber | RT~200 ℃ (as required) | ||
| Low-temperature chamber | RT~-70 ℃ (as required) | |||
| Temperature in the testing area | -40, -50, -60 ℃~120, 150 ℃ (selected as required) | |||
| Temperature fluctuation ≤ ± 0.5 ℃ | Temperature uniformity ≤± 2 ℃ | D Noise (dB) ≤ 65 | ||
| Heating and cooling rate | warm up | 60min/ RT~200℃ | ||
| cool down | 60min/ 0~-70℃ | |||
| Experimental method | temperature conversion | Pneumatic air door switching, ventilation type | ||
| Valve switching time | ≤5S | |||
| Temperature recovery time | ≤5min | |||
|
refrigeration | system | French fully enclosed Taikang compressor, cascade refrigeration (or semi enclosed valley wheel) | ||
| refrigerant | Cascade Level 2: R-23 (Fluorine free) | |||
| cooling | Air cooled (or water-cooled) | |||
| sensor | temperature | *Platinum resistor A (PT100) | ||
| humidity | *Platinum resistor A (PT100) | |||
| Box material | studio | #304 mirror stainless steel (1.2mm) | ||
| Outer box | Cold rolled steel plate electrostatic spraying (1.5mm) | |||
| insulation | Polyurethane+ultra-fine glass fiber (110mm below -50 ℃) | |||
| control | Japanese temperature control instrument, easy to operate, convenient to set, control accuracy of 0.01 ℃, programming beyond 1200 segments | |||
| heater | Fin type stainless steel heating system | |||
| evaporator | High efficiency heat exchanger | |||
| note | Non standard special requirements, can be customized | |||

Implement standards and test methods that meet the requirements
GB11158-2008 Technical Conditions for High Temperature Test Chamber
GB10589-2008 Technical Conditions for Low Temperature Test Chamber
GB10592-2008 Technical Conditions for High and Low Temperature Test Chambers (Temperature Alternating)
GB/T2423.1-2008 Environmental testing for electrical and electronic products Part 2: Test methods Test A: Low temperature (IEC60068-2-1:2007)
GB/T2423.2-2008 Environmental testing for electrical and electronic products Part 2: Test methods Test B: High temperature (IEC60068-2-1:2007)
GB/T2423.22-2002 Environmental testing for electrical and electronic products - Part 2: Test methods - Test N: Temperature variation (IEC60068-2-14)
GJB150.3A-2009 Military Equipment Laboratory Environmental Test Methods Part 3: High Temperature Test
GJB150.4A-2009 Military Equipment Laboratory Environmental Test Methods Part 3: Low Temperature Test
GJB150.5-1986 Temperature Shock Test
other
▣Operating environment temperature:+5~+35 ℃ (cooling environment temperature+5~+28 ℃ is preferred)
▣Safety: Short circuit protection, overtemperature protection, compressor overpressure protection, compressor overload protection, fan overload protection, leakage protection, phase sequence and phase loss protection, operator safety protection, specimen protection
Attachment Standard Configuration
▣Lighting: Philips 1
▣High end wheels: 4
▣Communication: SD card/USB/CF/Ethernet, optional according to the instrument