The SR-TGA-1250 thermogravimetric analyzer has two experimental modes, FTC and STC, which can be set to achieve more friendly and flexible temperature control. It can meet the needs of different application scenarios and experiments, with more accurate temperature control during the experimental process, more efficient analysis of sensor signals, and precise control of experimental results.
Product Details

Instrument Introduction:

Thermogravimetric analysis (TG, TGA) is the process of observing the changes in the mass of a sample with temperature or time during heating, constant temperature, or cooling, with the aim of studying the thermal stability and composition of the material. Widely used in research and development, process optimization, and quality monitoring in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials, and composite materials.

Thermogravimetric analyzer SR-TGA-1250Purpose:

Measure and study the following characteristics of materials: thermal stability, decomposition process, adsorption and desorption, oxidation and reduction, quantitative analysis of composition, effects of additives and fillers, moisture and volatile compounds, reaction kinetics, etc.

Thermogravimetric analyzer SR-TGA-1250Key Features:

1. Built in imported quality weighing balance, with internal calibration and temperature compensation functions, can quickly respond to quality changes, and has better accuracy and repeatability;

2. The instrument has a built-in quality level guidance function, and changes in sample position within the scale range do not affect the quality results;

3. The internal balance room is equipped with a constant temperature water bath device to ensure constant temperature, greatly improving the stability of weighing;

4. The instrument can perform experiments on sample weight gain or loss, such as the adsorption and decomposition processes of the sample;

5. The closed ceramic insulation furnace body structure greatly improves signal sensitivity and resolution, and can obtain a more stable baseline;

6. Modular design of furnace body, more flexible mobility, and easier maintenance;

7. The furnace is designed with a dual gas path blowing structure inside, which can better ensure the airtightness of the experimental process;

8. The interior of the furnace is designed with a capillary water circulation refrigeration structure, which wraps around the furnace and is used for cooling the furnace;

9. The furnace body can reserve experimental exhaust gas treatment interfaces according to customer needs, which can be used for secondary analysis of experimental exhaust gas;

10. The sensor bracket is designed with imported materials, which are more corrosion-resistant, anti-oxidation, and have high sensor sensitivity.

11. The sampling frequency of the sensor signal can be set between 0.05-10Hz, making the experimental method more flexible and the data more controllable;

12. The design concept of dual temperature sensors allows for simultaneous testing of both the internal temperature of the furnace and the sample temperature;

13. The fully temperature control system adopts an optimized dynamic PID algorithm, which greatly avoids the shortcomings of traditional PID algorithms and improves the robustness of dual-mode temperature control;

14. It has two experimental modes, FTC and STC, which can be set for more friendly and flexible temperature control, meeting the needs of different application scenarios and experiments. The temperature control during the experimental process is more accurate, the analysis of sensor signals is more efficient, and the experimental effect is accurately controlled;

15. The 12 level program temperature control setting makes the experimental methods more diversified, and the equipment has a cyclic scanning function, with a maximum of 9999 cyclic scanning times set and data automatically saved;

16. The lower and upper computers of the equipment system have multi-point temperature correction functions, which meet the needs of different experimental scenarios and improve the accuracy of temperature testing;

17. The instrument is equipped with an imported high-frequency core control processor, which has faster processing speed and more efficient control;

18. Independent atmosphere control can be achieved through software intelligent settings, and the instrument automatically switches the gas path system, resulting in higher experimental efficiency;

19. The equipment system can conduct experiments on materials related to heating, cooling, and isothermal processes;

20. Adopting a 7-inch 24 bit full-color LCD touch screen, the instrument's status and data are displayed in real-time.

Technical Specifications:

1

temperature range

Room temperature~1250 ℃

2

temperature resolution

0.01℃

3

temperature fluctuation

±0.01℃

4

heating rate

0.1~100℃/min

5

Measurement range of balance

0.01mg-5g

6

Quality resolution

0.01mg

7

incubation time

0-500 minutes (any setting)

8

Cooldown

30min(1000℃…100℃)

9

Timing frequency

16.6Hz

10

sampling rate

0.05-10Hz programmable settings

11

Experimental mode

FTC and STC modes can be set arbitrarily

12

experiment type

Weight loss, weight gain (adsorption)

13

Program temperature control

Flexible setting of 12 stage temperature control throughout the entire stage

14

Temperature control method

Heating, constant temperature, cooling

15

number of cycles

The number of cyclic scans can be set up to 9999 times, and the data is automatically saved

16

instrument calibration

Both the lower computer and the upper computer have multi-point temperature correction function

17

display mode

24 bit color 7-inch LCD touch screen display

18

Atmosphere control

Two atmospheres can be freely set, and the instrument automatically switches

19

Parameter standards

Equipped with standard substances, users can correct the temperature themselves

20

power supply

AC220V/50Hz (customizable AC110V)

Instrument configuration:

serial number

content

Quantity (units)

Remarks

1

SR-TGA-1250 Host

1 unit

2

power cord

1 piece

3

Experimental software USB drive

1 piece

4

data cable

1 piece

5

crucible

100 pieces

6

water pump

2 pieces

7

Water pump adapter

2 of them

8

multi-function wrench

1 piece

9

tweezers

1 piece

10

fuse

5 pieces

11

PU air tube

2 pieces

12

Silicone water pipe

4 pieces

13

Sample spoon

1 piece

14

Certificate of conformity, warranty card, instruction manual

1 copy

Note: The required equipment for your company includes a computer, nitrogen cylinder, oxygen cylinder, and accompanying pressure reducing gauge