Welcome Customer !

Membership

Help

Ansaisi (Beijing) Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Ansaisi (Beijing) Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    606, Block B, Chengyuan Building, Building 3, Jiancai Chengzhong Road, Haidian District, Beijing

Contact Now

Thermal analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Phase 12B is a subset of the Phase 12 thermal analyzer series. The main difference between the standard Phase 12 thermal analyzer and Phase 12B is that Phase 12B has an internal 100A power booster.

Product Details

热分析仪

Product Introduction:



NamePhase12BThermal analyzer

Model:Phase 12B

Brand:AnalysisTech

Origin: United States

Application:Phase 12BisPhase 12thermal analysisInstrument seriesThe subset. standardPhase 12Thermal analyzerandPhase 12BThe main difference between them isPhase 12BThere is an internal100APower booster.

Product Introduction



Phase 12BisPhase 12thermal analysisInstrument seriesThe subset. standardPhase 12Thermal analyzerandPhase 12BThe main difference between them isPhase 12BThere is an internal100APower booster.Phase 12BThe high current port on top exists in a single100AWithin the range, the maximum voltage is20V. Stage12BThe remaining parts and stages of the standard 12 The standards are the same, butHere it isfind

Phase 12BIntended to collaborate withKeysight GPIBPaired with controlled power supply, the latter is included inPhase 12BIn the discount attachment package.

Keysight GPIBThe availability of controlled power supplyCommunication input optionsincluding:

· 230VAC, single-phase(190 - 240VAC50/60HZ

· 208VAC, three-phase(190 - 240VAC50/60HZ

· 400VAC, three-phase(380 - 415VAC50/60HZ

Phase 12and12BElectrical specifications




All standardsThermal analyzerAll provided 210 or 20 The maximum heating current capacity of Ampere is determined by placing it after the model number“-2”“-10”or“-20”To express.Phase12BIt's standardPhase12Thermal analyzerThe high current version is only available 100 The maximum heating current capacity in amperes. The following specifications indicate 21020 and 100 Ampere unitWhere there are differences between them;Otherwise, the specifications apply to all versions. The requirements for AC power supply are assumed to be120 VAC50/60HzUnless otherwise specified at the time of ordering. For higher power testing,Power Booster You can use electricityExpanding streaming capacity to1000AAnd expand the heating power output to4500W.

电脑主机AI 生成的内容可能不正确。

图片包含 器具, 游戏机AI 生成的内容可能不正确。

Heating current,high rangeprecision±0.2%Reading addition,

2ASystem:±0.2mA; 10ASystem:±1mA; 20ASystem:±2mA; 100ASystem(Phase12B):±10 mA

Heating current, low range accuracy:±0.2%Reading addition,

2ASystem:±0.02 mA; 10ASystem:±0.1mA; 20ASystem:±0.2mA; 100ASystem(Phase 12B):±10 mA

Heating voltage measurement accuracy:

Phase12: Reading of±0.2% ±Full range0.025%(Usually)50V

Phase12B: Reading of±0.2% ±5mV20VFull scale)

Thermocouple measurement accuracy(TType standard):±0.15°C(Typical value)±0.3°C(Maximum value)

Accuracy and precision of junction temperature measurement:Tj Digital resolution:±0.007°C(Typical value) Tj Display accuracy:±0.1°C

Tj Absolute accuracy:±0.2to±0.5°CTypical values (see accuracy analysis))

Delay in junction temperature measurement:minimum1 microsecond AC power supply:120VACThe3AThe50/60Hz(Unless otherwise specified, as standard)

Maximum heating power supply voltage:50 Volts (other voltages available),20VwithPhase 12B

Maximum heating power supply current:2AThe10AThe20Aor100APhase 12B), nonepower amplifier

Tj Induction current selection:1mAThe5mAThe10mAThe20mAThe50mAAnd adjustable0.1 - 50mA

Data collection sampling rate:1 MHz

Phase 12/12BChassis size:17 inchx 17inchx 7.5Inches high,25 pound

requiredPCHardware:
Create a system:Windows 7orWindows 10Professional version,32/64Position, English version (including)
processor3 GHzSingle coreCPUOr higher,2 GB RAMmemory
Graphics: Any installation
WindowsThe main graphics card of the driver program Others:500 GBHard drive, at least 4 aUSBport