Overview
S4X-DTSeries DC signal transmitter is a type of DC signal transmitter that can isolate and convert input DC signals into standard analog output DC signals,Thus achieving instruments for measuring the measured signal. It adopts embedded standard guide rails(35mm)Installation, exquisite structure, easy to detect and maintain. This series of transmitters is convenient for remote monitoring in industrial automatic control systems and is widely used in automation systems in industries such as power, railway, petrochemical, metallurgy, chemical, food, and warehousing. It measures and monitors DC electricity and is a cost-effective product.
feature
This series of products has high measurement accuracy(± 0.1% RO, good conversion performance, wide input range, good temperature characteristics, and lightning protection function. It has long-distance transmission capability (4~20mA, 500 Ω), fixed in accordance with DIN46277, and can be installed on 35mm aluminum rails.
Selection:

Technical Specifications
Response time........................... Normal response≤400ms
Quick response≤50ms
Output ripple≤ 0.5% RO. (Peak to Peak)
Power consumption240V:≤AC 6VA,≤DC 5W
.........................110V:≤AC 4VA,≤DC3W
Using ambient temperature0~60℃
Temperature coefficient≤0.015%/℃
Storage environment temperature-10℃~70℃
High relative humidityRH90%
Insulation isolation(3 channels) Input/output/power supply
Medium strength(IEC 688).....................AC 2kV/1min
Insulation impedance≥100MΩ,DC500V
resistEMC Capability I. EC1000-4-5, Level 4
① To measure high current, a shunt is needed to convert it into a DC voltage signal before measurement.
② The fast response function is generally used in situations where the signal suddenly changes, and the output ripple varies with the input ripple; This function is not required for regular measurements. If the user has special requirements, please specify in the contract that customization is required.
③ If the user requires other special regulations, please specify the parameter values in the contract.