E-mail
366486898@qq.com
-
Phone
13615738271
-
Address
No. 211 Yanbei Road, Haiyan County, Haiyan Science and Technology Innovation Park
Haiyan Jinhan Electronic Technology Co., Ltd
366486898@qq.com
13615738271
No. 211 Yanbei Road, Haiyan County, Haiyan Science and Technology Innovation Park
Overview
S4-DT,S4(T)-DT,N3-DTSeries DCA transmitter is an instrument that can isolate and convert input DC signals into one (or two) sets of output DC signals, thereby achieving measurement of the measured signal. This transmitter has a wide range of input and output selection (voltage)-600V-0-600VCurrent can be converted into voltage through a shunt, with high accuracy (±)0.2%RO)Fast response capability (response time ≤0.5ms), and can simultaneously drive dual loads (two outputs); It adopts a standard relay socket connection method, with a delicate structure and plug and play capabilities, making it easy to detect and maintain. This series of transmitters is widely used in power and non power systems to measure and monitor DC power, making it a cost-effective product.
feature
This series of products has high measurement accuracy, good conversion performance, wide input and output range, good temperature characteristics, and lightning protection function. Capable of long-distance transmission(4~20mA, 500 Ω), fixed in accordance with DIN46277, can be installed on 35mm aluminum rails.
selection

Example of filling in model and parameters:
(1) S4(T)-DT-V8192N
0.2 level DC (voltage) transmitter
Voltage input range:0~100V;
Output range:4~20mA (single output);
Auxiliary power supply;AC220V
No need for quick response②.
(2) S4(T)-DT-0019192
0.2 level DC (voltage) transmitter
Voltage input range:-300V~0~300V;
Output range:Ⅰroad4~20mA;
Ⅱroad4~20mA(Two outputs);
Auxiliary power supply;AC220V
No need for quick response②.
(3) N4-DT-A6122N
0.2 level DC (current) transmitter
Voltage input range:0~5A
The splitter adopts5A/75mV);
Output range:4-5V (single output);
Auxiliary power supply;AC220V
No need for quick response②.
① All DC signals can measure negative input; To measure high current, a shunt is needed to convert it into a DC voltage signal before measurement.
② The rapid response function is generally used in situations where there is a sudden change in signal; Ordinary measurement does not require this function. If the user has special requirements, please specify in the contract that customization is required.
③If it is dual output, the auxiliary power supply can only beAC220V power supply.
④If the user requires other special regulations, please specify the parameter values in the contract.