Terasense Tunable Terahertz Source Frequency Expander
TERASENSE launches a new tunable terahertz source. A tunable terahertz generator consists of two parts: a frequency synthesizer (2-20 GHz) connected to a computer or tablet via USB; And a terahertz active frequency doubling module. The terahertz multiplication module is connected to a terahertz frequency synthesizer through an SMA cable, converting the frequency from the microwave range to the terahertz frequency range with a multiplication factor ranging from x4 to x18.

It should be pointed out that in addition to the conventional optional gain horn antenna, we can now offer another independent option, which is to install a Faraday isolator (also known as a Faraday valve) at the output of the generator. Faraday microwave isolator is a special device used to block reflected waves. When a severely mismatched load is connected to the generator output, the isolator will absorb almost all the power reflected back from the load, thereby isolating the output stage of the generator and preventing possible burnout.
Tunable terahertz sourceTechnical specifications and specifications
| parameter | ||||
| output frequency | 50 — 75 GHz |
75 — 110 GHz |
110 — 170 GHz |
220 — 330 GHz |
| output power | +15 dBm |
+13 dBm |
+8 dBm (typical) +10 dBm (maximum) |
+4 dBm (typical) |
| Input frequency range | 12.5 — 18.8 GHz |
12.5 — 18.4 GHz |
9.2 — 14.2 GHz |
12.2 — 18.3 GHz |
| input power | +5 dBm |
+5 dBm |
nominally 0 dBm (from -3 to +5 dBm ) |
|
| Frequency amplification factor | x4 |
x6 |
x12 |
x18 |
| output interface | WR-15 (UG-387) |
WR-10 (UG-387) |
WR-6 (UG-387) |
WR-3 (UG-387) |
| Power supply | 5 V DC, 20 W, 110–240 V |
5 V DC, 20 W, 110–240 V |
5 V DC, 20 W, 110–240 V |
9 V DC, 20 W, 110–240 V |
| input interface | SMA (F) |
SMA (F) |
SMA (F) |
SMA (F) |
| optional item | Faraday isolator optional | Faraday isolator optional |
Faraday isolator optional |
\\ |
Tunable terahertz sourceoutput characteristics




Precautions for using tunable terahertz sources
Exceeding the input power level may damage the instrument.
2. Electrostatic discharge may cause damage to equipment. It is recommended to wear a special grounding wristband when operating the instrument. The working environment around the instruments should also be well grounded.
3. Disassembling the device will damage its internal components. Terasense Group, Inc. is not responsible for warranty of products damaged due to improper use of the instrument.