Shanghai Weiming Temperature 0-100 ° C Humidity 0-100% Measurement and Control Instrument
Equipped with an integrated plastic box with temperature and humidity sensors, it can withstand temperatures up to 100 degrees Celsius
2 meters of standard connecting wire for instruments and sensors
Supporting one
Improve measurement accuracy and precision, promote air circulation
High temperature resistant (120 degrees) fully sealed waterproof fog fan
(* * To measure humidity in the air, it is necessary to keep the air constantly flowing)
Shanghai Weiming Temperature 0-100 ° C Humidity 0-100% Measurement and Control Instrument
Usage environment
Temperature:- 40~100℃
Humidity: 0~100% RH
measuremeasurerefinedDegree:
Temperature: ±0.5℃
Humidity: ±3~5%RH
resolving power: zero point one℃ 0.1%
Sampling period: 0.5 seconds
Measurement and control range
Temperature:- 40~100℃
Humidity: 0~100% RH
Display mode
Measurement value and set value displayed on digital tube
Output status, alarm status LED light indication
Shanghai Weiming Temperature 0-100 ° C Humidity 0-100% Measurement and Control Instrument
control mode
Binary control(warmlinear measureupperlimitbelowlimitThe return range can be set arbitrarily)
Binary control(wetlinear measureupperlimitbelowlimitreturn differenceFanencloseapproveappointmeaningSettings)
control output
Relay output: Contact capacity 250V AC 1A (resistive load)
warmlinear measureordinarycloseordinaryopenone
Voltage pulse output: 0~12V (suitable for solid)stateRelay SSR
Output contact
Electrical durability: 1 x 100000 times
Mechanical durability: 1X cycles
Shanghai Weiming Temperature 0-100 ° C Humidity 0-100% Measurement and Control Instrument
Installation method
Panel installation, embedded installation
The specific installation hole size is shown in the table

Shanghai Weiming Temperature 0-100 ° C Humidity 0-100% Measurement and Control Instrument
1. Insulation resistance:> 50MΩ(500VDC)
2. Insulation strength: 1500VAC/1 minute
3. Power consumption:< 10AV
4. Operating environment:In the range of 0~100 ℃ and 0~100% RH(Can be guaranteed for one year)
In the presence of non corrosive gases at 0-50 ℃ and 30-85% RH (guaranteed for two years)
5. Weight: Approximately 0.5KG (product power supply is a switch mode power supply)