E-mail
jh5120jh5120@163.com
-
Phone
18622580960
-
Address
No. 9 Taikang Road, Xiditou Industrial Park, Beichen District, Tianjin
Tianjin Tiandian Valve Co., Ltd
jh5120jh5120@163.com
18622580960
No. 9 Taikang Road, Xiditou Industrial Park, Beichen District, Tianjin
TIQ series electric actuatorsBrief description:
The IQ series actuators are a new generation of fully intelligent products produced with imported British technology, adopting non-invasive design. Integrating mechanical industry technology with microelectronics technology. This product has the characteristics of comprehensive functionality, reliable performance, small size, light weight, and easy use and maintenance. At the same time, the actuator adopts LCD liquid crystal display. Visually display the working status of the actuator in Chinese or English. Debugging is simple, operation is convenient, and various working states can be sent to the control system in any relay configuration. Widely used in industries such as petroleum, chemical, power, metallurgy, papermaking, and water treatment. The company not only provides technology and services, but also fully considers the cost of users to provide them with a high-performance and cost-effective product.
The IQ series provides a complete valve drive solution. It can adapt to all multi turn, angular stroke, and linear stroke valves that need to be controlled, providing users with high standard performance and high-quality service.
The IQ, IQM, IQL, and LQ series electric devices are the new generation of intelligent products. *The ultra large scale digital integrated chip, digital torque sensor and digital displacement sensor, fully Chinese menu operation and display, and mechatronics integrated structural design have created its * functionality, excellent performance, lightweight and beautiful appearance, simple debugging, and convenient operation. Paired with opening and closing components, it forms an execution unit and is applied in automatic control systems such as power stations, petroleum, steel, chemical, oil pipelines, and sewage treatment. It can meet the requirements of both frequent adjustment control and intermittent control. The standard code and name for this product: Q/ZTK 01-2009 "Electric Device".
1. The working principle of TIQ series electric actuators and electric actuators:
The IQ series multi turn intelligent electric actuator is driven by a single-phase or three-phase electric motor, and is reduced by a worm gear to drive the hollow output shaft to rotate. In this gearbox, there is a manual/automatic switching mechanism. When the switch handle is in the manual position, operate the handwheel and drive the hollow output shaft to rotate through the clutch.
The intelligent controller of the multi turn intelligent electric actuator receives standard analog current control signals or switch control signals, and compares them with the position signal of the valve position sensor to position the output shaft of the actuator at the corresponding position to the input signal, completing the positioning control. It can also be positioned at the pre-set position of the control system based on interlocking control, two-wire control, or event signals. Unless the output shaft torque value of the actuator exceeds the rated torque value or the set torque value during operation, the intelligent controller of the actuator will meet the requirements of the control system, issue correct instructions, trigger the solid-state relay, connect the motor to the power supply, and drive the actuator to operate normally.
The multi turn intelligent electric actuator adopts a non-invasive design, and the parameters and functions of the actuator can be modified or configured through a handheld remote control.
The IQL intelligent straight stroke electric actuator is based on the IQ multi turn intelligent electric actuator, and is combined with a trapezoidal nut screw, flange bracket, and stroke adjustment mechanism. Convert the multi turn torque and speed into linear motion stroke and shaft thrust.

2. Main features of electric actuators:
(1) Adopting large-scale digital integrated chips, with powerful functions and high precision levels.
(2) Mechatronics design, small size and light weight.
(3) By using a pressure sensor to measure the torque value of the output shaft, the accuracy of the torque measurement value has been improved, with an error rate of ≤ 5%. It can also dynamically monitor, display over torque, and alarm for locked rotor
(4) The displacement sensor adopts a Hall sensor and digitally quantifies the pulse signal, so the basic error of valve positioning accuracy is level 1 accuracy.
(5) The functions, parameter settings, debugging, and on-site electric operation of the electric device are all set through a handheld infrared remote control, without the need to open the box cover.
(6) Full Chinese and character display, menu style operation, intuitive and clear, easy to learn, understand, and operate.
3. Function of electric actuator:
(1) Travel limit protection function
(2) Torque limit protection function
(3) Status indicator contact function
1) Mid way limit; 2) The electric device is turning on; 3) The electric device is shutting down; 4) The electric device is running; 5) Stop on site; 6) On site control;
7) Remote control; 8) Valve opening interlock; 9) Valve closing interlock; 10) During handwheel operation; 11) Valve opening torque jumps off; 12) Valve closing torque jumps off; 13) Torque jump during travel
Valve alarm function:
1) Over torque alarm function: a. Over torque in the closing direction; b、 Driving direction over torque
2) Blocked rotation alarm function: a. Blocked rotation in the closing direction; b、 Turn direction blockage
Control alarm function: 1) Emergency event (ESD) alarm protection; 2) Signal interruption protection
Electric device alarm function:
1) Motor overheating protection; 2) Control box overheating protection; 3) Low battery level protection
4) Internal power failure protection; 5) Power phase loss and phase drop protection; 6) Internal system fault protection
7) Current valve position signal loss protection; 8) Local wiring fault alarm
Instantaneous reverse protection function, on-site control, jog/self hold selection function
Contact mode selection function External interlock protection function Condition control protection function
Two line control protection function, torque bypass protection function, ESD override protection function
Interrupt setting power additional indication contact function remote control setting function
Execution mechanism display function, three-phase power supply phase sequence automatic discrimination function
| ||||||||||
| Output speed of actuator (50Hz) | ||||||||||
| 18 | 24 | 36 | 48 | 72 | 96 | 144 | 192 | |||
| Model of actuator | Torque (Nm) Power (KW) | |||||||||
| IQ10 | 34 | 34 | 34 | 34 | 34 | 34 | ||||
| 0.05 | 0.07 | 0.09 | 0.11 | 0.15 | 0.19 | |||||
| IQ12 | 81 | 81 | 81 | 68 | 48 | 41 | ||||
| 0.13 | 0.16 | 0.21 | 0.21 | 0.21 | 0.23 | |||||
| IQ18 | 108 | 108 | 108 | |||||||
| 0.17 | 0.21 | 0.23 | ||||||||
| IQ20 | 203 | 203 | 203 | 203 | 176 | 142 | 102 | |||
| 0.32 | 0.40 | 0.53 | 0.64 | 0.76 | 0.80 | 0.81 | ||||
| IQ25 | 400 | 400 | 298 | 244 | 244 | 230 | 149 | |||
| 0.63 | 0.78 | 0.78 | 0.77 | 1.06 | 1.29 | 1.19 | ||||
| IQ35 | 610 | 610 | 542 | 474 | 474 | 366 | 257 | |||
| 0.96 | 1.19 | 1.42 | 1.50 | 2.06 | 2.04 | 2.06 | ||||
| IQ40 | 1020 | 1020 | 845 | 680 | 680 | 542 | 406 | |||
| 1.60 | 1.98 | 2.22 | 2.14 | 2.94 | 3.03 | 3.24 | ||||
| IQ70 | 1490 | 1490 | 1290 | 1020 | 1020 | 745 | 645 | 542 | ||
| 2.34 | 2.91 | 3.37 | 3.21 | 4.41 | 4.16 | 5.14 | 5.59 | |||
| IQ90 | 2030 | 2030 | 1700 | 1355 | 1355 | 1020 | 865 | 730 | ||
| 3.19 | 3.96 | 4.44 | 4.29 | 5.87 | 5.68 | 6.92 | 7.55 | |||
| IQ91 | 1355 | 1355 | |||||||
| 10.82 | 13.98 | ||||||||
IQ95 | 3000 | ||||||||
| 5.81 | |||||||||
| Note: IQ-IB/IS combination can reach 43386Nm (multi turn); IQ-IW combination can reach 137000Nm (90 degree output) | |||||||||
| mechanical data | |||||||||
actuator | IQ10 | IQ20 | IQ35 | IQ40 | IQ70 | IQ90 | IQ91 | IQ95 | |
| IQ12 | IQ25 | ||||||||
| IQ18 | |||||||||
| Flange model ISO5210 | F10 | F14 | F16 | F25 | F25 | F30 | F25 | F30 | |
| Weight of actuator (Kg) | 32 | 52 | 52 | 75 | 215 | 230 | 220 | 230 | |
| Maximum allowable stem diameter A-type mm | 32 | 38 | 54 | 64 | 70 | 70 | 73 (Z-type) | 83 (Z-type) | |
| threaded interface | IQ10-- IQ95 are both one M40 and two M25, or one 1.5 'and two 1' | ||||||||
| design life | 10000 times on/off | ||||||||
| operating frequency | 60 times/hour | ||||||||
| Operating Temperature | -30 degrees Celsius -+70 degrees Celsius | ||||||||