TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler Product Introduction: The instrument integrates two channels of atmospheric sampling, two channels of 24-hour constant temperature and current sampling, and one channel of TSP sampling, making it versatile and capable of sampling various particulate matter and gas components in the air. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc. 2、 The TC-6180C atmospheric/24-hour/TSP comprehensive sampler adopts biao zhunJJG 956-2013 "Atmospheric Sampler" HJ/T 376-2007 "Technical Requirements and Testing Methods for 24-hour Constant Temperature Automatic Continuous Environmental Air Sampler" HJ2.2-2008 "Technical Guidelines for Environmental Impact Assessment Atmospheric Environment" HJ/T 374-2007 "Technical Requirements and Testing Methods for Total Suspended Particle Sampler" JJG 943-2011 "Total Suspended Particle Sampler" HJ 618-2011 "Determination Weight Method for Environmental Air PM10 and PM2.5" HJ/T 93-2013 "Technical Requirements and Testing Methods for Environmental Air Particle (PM10 and PM2.5) Sampler" Q/0213TWB 001-2014 Enterprise biao zhun San Main features: 1. Two atmospheric channels, two 24-hour channels, and one TSP particulate matter sampling channel; 2. The high-speed processor automatically calculates and controls the sampling flow rate, and compensates for flow changes caused by voltage fluctuations and resistance changes; 3. Atmospheric and 24-hour sampling gas path configuration .....
Product Details

TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler

1、 TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler Product Introduction

The instrument integrates two atmospheric sampling channels, two 24-hour constant temperature and current sampling channels, and one TSP sampling channel, making it versatile and capable of sampling various particulate matter and gas components in the air. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc.
IITC-6180CThe atmospheric/24-hour/TSP comprehensive sampler adopts biao zhun
JJG 956-2013 Atmospheric Sampler
HJ/T 376-2007 "Technical Requirements and Testing Methods for 24-hour Constant Temperature Automatic Continuous Environmental Air Samplers"
HJ2.2-2008 Technical Guidelines for Environmental Impact Assessment - Atmospheric Environment
HJ/T 374-2007 Technical Requirements and Testing Methods for Total Suspended Particle Samplers
JJG 943-2011 "Total Suspended Particle Sampler"
HJ 618-2011 "Determination of PM10 and PM2.5 in ambient air by gravimetric method"
HJ/T 93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"
Q/0213TWB 001-2014 Enterprise biao zhun

3、 Main features
1. Two atmospheric channels, two 24-hour channels, and one TSP particulate matter sampling channel;
2. The high-speed processor automatically calculates and controls the sampling flow rate, and compensates for flow changes caused by voltage fluctuations and resistance changes;
3. The atmosphere and 24-hour sampling gas path are equipped with anti backflow suction drying bottles to prevent the absorption liquid from being sucked back;
4. Pipeline blockage protection function: During the atmospheric and 24-hour sampling process, if the pipeline is blocked or the load is too high, the system will automatically stop the pump to protect the instrument from damage due to long-term overload. If the load is greater than negative 20kPa for a long time, the protection function will be automatically activated;
5. 24-hour constant temperature sampling: electronic semiconductor dual cooling and rapid heating device, adjustable temperature (15-30) ℃;
6. High performance ultra-low frequency brushless diaphragm pump is used for atmospheric and 24-hour sampling, with a long service life;
7. The atmosphere and 24-hour sampling are connected using red and blue dual color gas path connecting pipes, making it easy and accurate to connect the gas path;
8. Automatically measure ambient atmospheric pressure and temperature, display real-time sampling flow rate, cumulative sampling volume, and standard condition volume;
9. Built in real-time clock, which can pre-set the sampling start time;
10. Timed sampling can be set, with equal intervals for multiple samplings. The number of samplings can be arbitrarily set between 1 and 99 times;
11. The particulate matter sampling adopts an imported DC fan with a continuous operation life of over 20000 hours.
12. The TSP/PM10/PM2.5 sampling head is made of aluminum alloy material and has anti-static adsorption;
13. Power off protection function, automatic sampling of incoming calls;
14. The Chinese LCD screen with automatic contrast adjustment can work normally at minus 30 degrees Celsius;
15. Equipped with a height adjustable triangular bracket;
16. Equipped with RS232 digital communication interface, it can be connected to an external printer for convenient data output.
4、 Technical indicators

technical indicators parameter range resolution accuracy
Atmospheric sampling flow rate (0.1~1.0)L/min 0.01L/min Better than ± 2.5%
24-hour sampling flow (0.18~0.22)L/min, Constant current at 0.20L/min 0.1L/min Better than ± 2.5%
Sampling of particulate matter (60~130)L/min 0.1L/min Better than ± 2.0%
Traffic repeatability Better than ± 2.0%
Traffic stability Better than ± 2.5%
Pre measurement pressure (-20 to 0)kPa 0.01kPa Better than ± 2.5%
Environmental atmospheric pressure (70~130)kPa 0.01kPa Better than ± 0.2%
Single channel air with the largest sampling volume 9999.99L 0.01L Better than ± 2.0%
sampling time 1min~99h59min 1min Better than ± 0.2.%
The largest volume of particulate matter sampling 999999.99L 0.1L Better than ± 2.0%
constant temperature 23 ℃ (default, other adjustable) 0.1℃ Not exceeding ± 1.5 ℃
Timed startup 24-hour clock
Equidistant sampling time Set freely within 99 hours and 59 minutes
Equal interval sampling frequency 1 to 99 times
noise <55dB(A)
Overall dimensions (W × D × H) mm 260×380×300
weight About 8.0kg
power supply AC220V±10% 50HZ
power consumption <300W
Sampling head indicators
PM2.5 cutting characteristics Da50 = (2.5±0.2)μm 〥g = (1.2±0.1)μm
PM10 cutting characteristics Da50 = (10±0.5)μm 〥g = (1.5±0.1)μm
Entrance speed 0.3m/s
b/a 0.625
sampling flow 100L/min
Effective filter membrane diameter Ф80mm
connector M20×1.5

5Packing List

serial number name unit quantity Remarks
1 host Taiwan 1
2 Main aluminum box a 1
3 TSP sampling head a 1 PM10 and PM2.5 are optional sampling heads
4 Ø 4.5 × 8 gas path connecting pipe root 1 Red 40cm
5 Ø 4.5 × 8 gas path connecting pipe root 1 Red 28cm
6 Ø 4.5 × 8 gas path connecting pipe root 1 Blue 44cm
7 Ø 4.5 × 8 gas path connecting pipe root 1 Blue 28cm
8 Ø 4.5 × 8 gas path connecting pipe root 1 Red 22cm
9 Ø 4.5 × 8 gas path connecting pipe root 1 Red 30cm
10 Ø 4.5 × 8 gas path connecting pipe root 1 Blue 25cm
11 Ø 4.5 × 8 gas path connecting pipe root 1 Blue 26cm
12 Anti reverse suction dryer a 4
13 Absorption bottle a 4
14 bracket a 1
15 power cord root 1
16 triangular bracket a 1
17 Sampling filter membrane box 1
18 Filter membrane clamp box a 1
19 Product Manual copy 1
20 Product Qualification Certificate copy 1